Optex FlipX FLX-A-DAM Handleiding

Optex Niet gecategoriseerd FlipX FLX-A-DAM

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Optex FlipX FLX-A-DAM (17 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/17
FlipX series
Flexible Range Indoor Detector
Flexible Range Indoor Detector
FlipX series
ADVANCED MODELS
INSTALLATION INSTRUCTIONS
59-3112-0 2208-31
UL 59- 2110-013112-0
EN
1
- Manufacturer's statement
- Parts identification
- Anti-masking
- Specifications
- Events and responses
- LED indications
- Dimensions
- Detection area
- Angle adjustment
with bracket CW-G2/CW-G3
- Compliance
Before installation
Others
<< Contents >>
Page
2
3
EOL settings
Down zone ON/OFF
Settings
2
Checking3
6
13
Volume setting
Wide/Narrow setting
Wide/Narrow area
Flip lens
PIR Anti-masking Microwave
FLX-A-AM -βœ“ βœ“ βœ“
FLX-A-DAM-X5
*1
βœ“ βœ“ βœ“ βœ“(10.525 GHz)
FLX-A-DAM-X8
*2
βœ“ βœ“ βœ“ βœ“(10.587 GHz)
FLX-A-DAM-X9
*3
βœ“ βœ“ βœ“ βœ“(9.425 GHz)
*1 Not certified to INCERT, NF
*2 Not certified to UL and SBSC
*3 Not certified to EN 50131-2-4, NF, INCERT, SBSC and UL
Installation
Wall mount
without bracket
Wiring
1
Wall mount
with bracket
Ceiling mount
with bracket
Disassemble 4
8
5
10
7
3
12
12
11
14
15
15
16
17
17
17
DIP switch settings 12
Mounting height
2.0 to 3.0 m (6’7” to 9’8”)
2.4 m (8’) recommended
W garnin
Caut nio
< 1 m
Wetting with water
[ FLX-A-DAM only ]
Destroy
modify
<1 m
Outdoor installation
Detection through glass
Face to face/Back interference
Partial/complete obscuration
of the detection area.
Follow to the regulations
- Manufacturer’ s statement
NOTE
Failure to follow the instructions provided with this indication
and improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication
and improper handling may cause injury and/or property damage.
Check mark indicates recommendation.
Nix sign indicates prohibition.
Special attention is required to the
section of this symbol.
Symbol Meaning
W garnin
Caut nio
Symbol Meaning
Before installation
2
Options
Cover
Main unit
Base
- Parts identifications
3
Sponge
Lens
CW-G3 *: Bracket for wall/ceiling mount
with tamper switch
Accessories
Mount screw x 2
PEU: Plug-in EOL Unit
Do not touch and units. PIR MW
* Not certified to EN 50131-2-2/EN 50131-2-4,
INCERT and SBSC
- Anti-masking
Wall tamper screw x 1
Joint screw x 3
Fixing screw x 2
Overview of anti-masking
If the front of the lens is covered with obstacles over 20 seconds, an alarm and trouble will be output.
Sensitivity setting
(Refer to β€œ2-3 Dip switch/Volume settings” - β€œ
   Anti-masking sensitivity” )
Normally, use it in β€œMiddle” .
Select the β€œHigh” setting if required by any standards or sensitivity is insufficient.
If there are many false alarms, you can use β€œLow” , but please note that it may not be output depending
on the materials and colors of the obstacles.
54


Product specificaties

Merk: Optex
Categorie: Niet gecategoriseerd
Model: FlipX FLX-A-DAM

Heb je hulp nodig?

Als je hulp nodig hebt met Optex FlipX FLX-A-DAM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Optex

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd