CONTENTS
·Multiple beam installation of up to 4 sets
·Simple optical alignment
·High waterproofing property; jet-proof : IP65
·Wide optical alignment range:
±90 degrees horizontally; ±20degrees vertically
*AX-350DH BT:
±60 degrees horizontally; ±45 degrees vertically
·Reduced possibility of false alarms caused by flying
objects
1. INSTALLATION GOOD PRACTICE
2. PARTS IDENTIFICATION
3. NOTES ON INSTALLATION
4. INSTALLATION METHOD
5. TERMINAL CONNECTIONS
6. WIRING
7. OPTICAL ALIGNMENT
8. BEAM INTERRUPTION TIME ADJUSTMENT
9. RE-TRANSMISSION FUNCTION
10. WALK TEST
11. HEATER UNIT HU-2
12. BACK COVER BC-1
13. DIMENSIONS
14. TROUBLESHOOTING
15. SPECIFICATIONS
2
3
3
4
6
7
8
11
11
12
12
13
13
15
16
-1-
INSTALLATION
INSTRUCTIONS
top/bottom unit AND/OR selectable
maximum detection range: 350ft.(100m)
PHOTOELECTRIC DETECTOR
·Digital communication function
·Cross talk prevention function
·Peak Finder Interface (P.F.I ) of Dual Alignment
Level Indicator
·Mode-specific indicator allowing simple and
accurate optical alignment
·Simple beam alignment without the “Beam
Blocking Tool”
·Minimization of light disturbance
·ATPC ( Auto Transmit Power Control )
to optimize the power of beam
Thank you for purchasing our product.Be sure to read the
following installation instructions carefully before beginning
installation.Make sure that the person in charge of system
management stores this manual carefully for maintenance
and management.
model for beam tower, upper and lower unit unit AND/OR selectable
maximum detection range: 350ft.(100m)
maximum detection range: 350ft.(100m)
maximum detection range: 650ft.(200m)
Downloaded from manuals search enginewww.Manualslib.com
-3-
28-39inch(0.7-1m)
23.5 inch(60cm)
39 inch(1m)
2. PARTS IDENTIFICATION
Mounting Plate
Wall Mounting Screw
Holes & Waterproof
Plug (x 4)
Vertical Alignment Dial
Terminals
See 5. “TERMINALon PAGE6.
Horizontal Alignment Dial
View Finder
Cover Lock Screw
Cover
Unit Base
Mounting Screw
(x 4)
Wiring Hole (x 2)
Monitor Jack
Alignment Level Indicator
Unit Base Pole Mounting
Screw Holes &
W a t e r p r o o f
Plug (x 4)
Rubber
Bushing
Rubber Bush Slot
Pole Mounting
Screw Holes &
Waterproof Plug
(x 4)
Hood
Hood
Switch Section
Transmitter
Receiver
Clears the registered address (see 14. “TROUBLESHOOTING” on Page15).
Indicates the registered address by the flickering of the six indicator LEDs for about 10
seconds (see 14. “TROUBLESHOOTING” on Page15).
Switches between high and low the level of infrared beam reception output to the monitor
jack.
Use this switch for multi-level installation (see 7-2. “Master/slave selector switch setting on
Page8).
Switches the interruption time between the four settings (see 8. “BEAM INTERRUPTION TIME
ADJUSTMENT” on Page11).
This switches the detection time for the top unit when AX-350DH TS / BT in the OR mode.
Switch to the AND mode for detection of simultaneous interruption for the top and the bottom
units and to the OR mode for detection of interruption for either unit (see 7-3. “AND/OR
selector switch setting” on Page8).
Turning the switch to ON in the OR mode fixes the interruption time for the bottom unit to one
second (see 8. “BEAM INTERRUPTION TIME ADJUSTMENT” on Page11).
ADDRESS CLEAR:
ADDRESS CHECK:
MONITOR JACK switch:
MASTER/SLAVE switch:
INTERRUPTION TIME switch:
AND/OR switch:
(AX-350DH TS / BT only)
Resets the registered address to the factory settings
(see 14. “TROUBLESHOOTING” on Page15).
Indicates the registered address by the flickering of the six indicator LEDs for about 10 seconds
(see 14. “TROUBLESHOOTING” on Page15).
Switches between high and low the level of infrared beam reception output to the monitor jack.
Use this switch for multiple beam installation (see 7-2. “Master/slave selector switch setting” on Page8).
When more than one detector with the same address is on the alarm line, switches one of them
to prevent malfunction caused by cross talk (see 14. “TROUBLESHOOTING” on Page15).
Switch to the AND mode for detection of simultaneous interruption for the top and the bottom
units and to the OR mode for detection of interruption for either unit (see 7-3. “AND/OR selector
switch setting” on Page8).
ADDRESS CLEAR:
ADDRESS CHECK:
MONITOR JACK switch:
MASTER/SLAVE switch:
FORCED ADDRESS switch:
AND/OR switch:
(AX-350DH TS / BT only)
BOTTOM UNIT INTERRUPTION TIME switch:
(AX-350DH TS / BT only)
3. NOTES ON INSTALLATION
[2] Alignment angle[1] Detection range and installation height [3] Pole mounting
·Pole size should be diameter
1.9inch(48mm).
·The length of the wiring cable out of
the pole should be within 23.5
inch(60cm).
Without AX-350DH BT
180 degrees (± 90 degrees) 40 degrees (± 20 degrees)
AX-350DH BT
120 degrees 60 degrees) 90 degrees (± 45 degrees)
distances between the Receiver and
the Transmitter are listed below:
Horizontally Vertically
35-350ft.(10-100m) : AX-350DH MK III, AX-350DH TS,
AX-350DH BT
65-650ft. (20-200m) : AX-650DH MK III
Normally, the installation height should
be 0.7 1.0m. When OR mode is used,
the installation height of lower beam
should be 15cm from the ground.
For best performance, avoid aligning
detectors at 45 degree angles except
AX-350DH BT.
Note
Downloaded from manuals search enginewww.Manualslib.com
-12-
*AX-350DH TS and AX-350DH BT has
alarm output for lower detector.
1
2
3
10. WALK TEST
Make sure that the “Alarm condition”
LED is OFF. If it is illuminated even
when the beams are not blocked,
make optical alignment again.
If the Alarm condition LED is
turned ON when the beam is
blocked, installation is complete.
Be sure to conduct a walk test (to
block the infrared beam) at the
following three points:
1. In front of the Transmitter
2. In front of the Receiver
3. At the middle point between the
Transmitter and the Receiver
If the “Alarm condition” LED is not illuminated even if the beam is blocked, follow the instructions in “14.
TROUBLESHOOTING” on Page15 and solve any problem.
Alarm condition
Note
Receiver
Transmitter
Alarm condition
11. HEATER UNIT HU-2 (Option)
11-1. Mounting method
- Feature -
The heat release effect makes the unit less prone to frost.
When connecting the heater unit leads to the wiring, solder the wires or use the
connectors provided with the heater unit and securely connect the wires one by
one.Put the connector on the wires and crimp with pliers, etc.
Remove the cap from the wiring hole and pull the wire through the hole. Then
thread the wiring packing down to about 6 inch from the end of the wire and
securely tighten the cap.
Remove the release paper on the rear of the heater unit and paste the unit in line
with the guide of the mounting plate for both the top and the bottom levels.
Power supply of 24 VAC/DC is required to use the heater unit.
Use separate wiring from that of the detector because the current
draw of the heater unit can be as large as 430 mA each.
Be sure to mount the heater unit for both the top and the bottom
levels. Otherwise the effectiveness may be reduced.
Note
Note
WIRING DISTANCE
AWG18 (0.83mm2)500'(150 )
AWG16 (1.31mm2)850'(250)
AWG14 (2.09mm2)1300'(400)
WIRE SIZE
11-2. Wiring distance between power supply and detector
·Ensure that the wiring distance from the power supply is within the range shown
in the table on the right.
·When using two or more units on one wire, the maximum length is obtained by
dividing the wire length listed below by the number of units used.
*AX-350DH TS and AX-350DH BT has
alarm output for lower detector.
Downloaded from manuals search enginewww.Manualslib.com


Product specificaties

Merk: Optex
Categorie: Niet gecategoriseerd
Model: AX-350DH MK3

Heb je hulp nodig?

Als je hulp nodig hebt met Optex AX-350DH MK3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Optex

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd