99046155 rev. A
WWW.NUTONE.COM
CHIMNEY
RANGE HOOD
NW830SS
INSTALLATION, USE
AND CARE MANUAL
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturers guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. To provide protection against electric shock, connect to properly
grounded outlet only.
11. When applicable local regulations comprise more restrictive
installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the installer
agrees to conform to these at his own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it becomes overheated. The motor will
restart when it cools down. If the motor continues to shut off
and restart, have the hood serviced.
5. The minimum hood distance above cooktop must not be less
than 26". For best capture of cooking impurities, the bottom
of the hood should be at a maximum of 30" above cooking
surface. For a gas range, the bottom of the hood MUST NOT
BE LESS than 30" above cooktop.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
9. To reduce the risk of fire and electrical shock, the NuTone NW8
Series models should only be installed with their own built-in
blower.
10. When used in recirculation mode, to reduce the risk of fire and
shock, use only conversion kit model RK58.
11. Please read specification label on product for further information
and requirements.
WARNING
!
CAUTION
WARNING
!
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
Register your range hood online at www.nutone.com
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 10.
READ AND SAVE THESE INSTRUCTIONS
! !
3
1. PREPARE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. SELECT INSTALLATION TYPE . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. WIRING INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. INSTALL HOOD MOUNTING BRACKET . . . . . . . . . . . . . . . . . . . . 4
5. INSTALL UPPER FLUE MOUNTING BRACKET . . . . . . . . . . . . . . . . 5
6. REMOVE GREASE FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7. INSTALL 6” ROUND ADAPTER DAMPER/ . . . . . . . . . . . . . . . . . . . 5
8. INSTALL THE HOOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
9. DUCT CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
10. PREPARE THE DECORATIVE FLUE . . . . . . . . . . . . . . . . . . . . . . 8
11. INSTALL THE DECORATIVE FLUE . . . . . . . . . . . . . . . . . . . . . 8-9
12. REINSTALL GREASE FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . 9
13. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
14. CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
15. REPLACEMENT PARTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
16. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
TABLE OF CONTENTS
1. PREPARE INSTALLATION
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer.
Make sure that the following items are included:
- Hood
- Decorative flue assembly (lower and upper flues)
- Hood mounting bracket
- Lower flue mounting bracket
- Upper flue mounting bracket
- 2 Aluminum grease filters
- 6” Round adapter/damper
- Installation instructions
- Parts bag: 10 no. 8 x 5/16 mounting screws,
7 no. 8 x 1½ mounting screws,
7 drywall anchors, 2 washers
Parts sold separately:
- Ducts, elbows, wall and roof caps.
- Optional flue extension for 10-ft. ceilings model FXN58SS.
- Non-duct kit model RK58, mandatory for non-ducted installation.
NOTE: During installation, protect countertop and/or cooktop.
HR0202A
DECORATIVE
FLUE
L OWER FLUE
MOUNTING BRACKET
HOOD
MOUNTING BRACKET
U PPER FLUE
MOUNTING BRACKET
6” R OUND
ADAPTER DAMPER/
2. SELECT INSTALLATION TYPE
2.1 NON UCTED NSTALLATION-D I
The RK58 non-duct kit is required for a non-ducted installation.
2.2 DUCTED NSTALLATION I
Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently. Long duct
runs, elbows and transitions will reduce the performance of the hood. Use as few
of them as possible. Larger ducting may be required for longer duct runs.
Install wall or roof cap. Connect 6” round metal ductwork to cap and work back
towards the hood location. Use 2” metal foil duct tape to seal the joints.
2.3 ALL NSTALLATIONS I
The minimum hood distance above cooktop is 26” (30” over a gas range).
A maximum of 30” above cooktop is recommended for best capture of cooking
impurities.
Distances over 30” are at the installer and users discretion providing that ceiling
height and decorative flue length allow it.
6” ROUND
DUCT
R OOF CAP
6” ROUND
ELBOW
W ALL
CAP
HOOD
DECORATIVE
FLUE
HH0251A
26” MINIMUM ABOVE
COOKING SURFACE
(30” )FOR GAS RANGE
WARNING
!
!
!
!!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.


Product specificaties

Merk: NuTone
Categorie: Afzuigkap
Model: NW830SS

Heb je hulp nodig?

Als je hulp nodig hebt met NuTone NW830SS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap NuTone

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap