Norlake NLBB72NG Handleiding

Norlake Koelkast NLBB72NG

Lees hieronder de 📖 handleiding in het Nederlandse voor Norlake NLBB72NG (8 pagina's) in de categorie Koelkast. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
1 10 143594/15 Rev. L
BACK BAR REFRIGERATION
Installation, Operation and Maintenance Instructions
INSPECTION
When the equipment is received, all items should be carefully checked against the Bill
of ading to eL nsure all crates and cartons have been received. Do not sign the freight
bill clear until the freight has been properly inspected for damage. All units should be
inspected for damage including concealed damage by uncrating immediately. If any
damage is found, it should be reported to the carrier at once, noted on the Bill of Lading
and a claim should be filed with the carrier. This equipment has been inspected and
tested in the manufacturing facility and has been crated in accordance with
transportation rules and guidelines. The manufacturer is not responsible for freight loss
or damages.
INSTALLATION
After removing the unit from the packaging, clean the interior and exterior surfaces of
the unit with soap and water and a rinse with clean water. Do not use chlorinated
cleaners on the surfaces as they can cause corrosion.
This unit is designed for indoor use only. Be sure to locate the unit where the floor can
support the weight of the unit and product installed inside of it. The refrigeration system
located at the bottom left of the unit requires free air access for proper operation. Allow
a minimum of seven (7) inches between the back of the cabinet and the wall. Do not
locate the unit next to heat generating equipment or in direct sunlight.
Confirm that the proposed electrical outlet has the correct voltage, frequency and
current carrying capacity for the requirements of the unit. This information is noted on
the data plate on the inside left wall of the unit. The unit should be isolated on a circuit.
Do not use an extension cord to get power to the unit. Improper electrical installations
will void the compressor warranty. To prevent shock and fire, be sure the unit is properly
grounded.
Local health codes may require that the unit be sealed to the floor with an NSF
approved silicone sealant if it is not on legs or casters. After the unit is set in its desired
location, simply apply a bead of sealant around the base of the unit and smooth it out.
The shelves and shelf support clips are shipped inside the cabinet. Install the shelf
support clips on the pilasters mounted on the inside walls of the cabinet and set the
shelves on the supports. The shelves are adjustable in increments to suit your ½
needs.
If the doors have come out of alignment during shipping, they will need to be adjusted.
This can be accomplished by opening the door(s) and loosening the screws that hold
both the top and bottom hinges to the cabinet. After adjusting the door so it is aligned
correctly, tighten the screws to securely hold the hinges and door(s) in place.
2 10 143594/15 Rev. L
OPERATION AND MAINTENANCE
This cooler is designed to maintain your product temperature within the most desirable
r +ange of 34°F to + °F. You can expect this temperature with the proper temperature 38
control setting and in a normal environment. It is important to remember that when the
product is delivered, it must be placed inside the cooler as soon as possible to avoid
excessive warm up. If this happens, it may take many hours for the temperature to be
reduced to the desirable range.
The temperature controller is located on the left end of the unit cooler. Turn the control
clockwise for cooler temperatures and counterclockwise for warmer temperatures.
Allow the unit several hours to respond to temperature control adjustments.
There are interior lights located above the door. has an on/off switchThe light on the
unit cooler.
When loading the cabinet with product, do not block the air flow path. Blocking the air
flow may decrease performance. Maintain clearance between the contents and air duct
for best performance.
This equipment is intended for the storage and display of pre-packaged food product
only.
Cleaning
Beginning with the initial installation, the interior surfaces of the cabinet should be
periodically cleaned with a solution of warm water and baking soda. This solution will
remove any odors from spillage that has occurred. The exterior of the cabinet should
also be cleaned frequently with a commercial stainless steel cleaner, glass cleaner or
mild soap solution. Do not use chlorinated cleaners on any surfaces.
Note: do not use stainless steel cleaners or other solvent-based chemicals on the
plastic parts (door handle or trim strips) as they can cause failure. Use mild soap and
warm water on plastic parts.
The shelving can be cleaned in a sink with a mild soap solution and a soft bristled
brush.
Condenser Coil
Prior to cleaning the condenser coil disconnect the unit from power. Periodic cleaning
of the condenser coil will aid the heat transfer of the refrigeration system and increase
its efficiency. To accomplish this, remove the lower front grill from the cabinet. The
condenser coil is located behind the grill. Use a soft bristled brush to remove any dirt
particles that are on the fins of the condenser coil. Use a vacuum cleaner or
compressed air to remove the loosened particles. Replace the front grill and reconnect
the unit to power. Failure to clean the condenser coil can lead to performance loss and
compressor failure.
3 10 143594/15 Rev. L
TROUBLESHOOTING
Problem
Remedy
Compressor will
not start
· Check the power cord and make sure it is plugged in and has power.
· Check the temperature controller. If it is in the “OFF” position,
turn it clockwise to set a desired temperature.
Poor performance
· Move the unit from direct sunlight.
· Move the unit away from heating devices.
· Install the unit in a well ventilated place, with at least 2 inches of clearance on all
sides.
· Clean the condenser if heavy dust is collected.
· Clear contents from blocking the inside air duct.
· Check the temperature controller for correct setting.
· Check the and be sure they are completely closed.doors
Unit noisy
· Install the unit on a level solid surface.
· Maintain 2 inches of clearance from the wall.
· Check for loose part or mounting.s
· Keep the tubing free from any contact to avoid rattle.
Condensation on
cabinet exterior
and/or floor
· Reduce humidity where the unit is installed.
· Check the drain line to make sure it is not disconnected inside the cabinet and it
the drains into drain pan in the compressor area.
SPECIFICATIONS*
* Above specifications are subjected to change without prior notice for quality
improvement.
Model
# of
D oors
# of
Shelves
Electrical
Amps
HP
Refrigerant
Capacity
12oz. cans
BB59
2
4
115/60/1
3.3
1/5
R- 134a
1084
BB59G
2
4
115/60/1
5.0
1/5
R- 134a
1084
BB69
2
4
115/60/1
5.0
1/3
R- 134a
1299
BB69G
2
4
115/60/1
5.0
1/3
R- 134a
1299
BB79
3
6
115/60/1
6.0
1/3
R- 134a
1566
BB79G
3
6
115/60/1
6.3
3/8
R- 134a
1566
BB95
3
6
115/60/1
6.3
3/8
R- 134a
1875
BB95G
3
6
115/60/1
6.3
3/8
R- 134a
1875


Product specificaties

Merk: Norlake
Categorie: Koelkast
Model: NLBB72NG

Heb je hulp nodig?

Als je hulp nodig hebt met Norlake NLBB72NG stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Koelkast Norlake

Handleiding Koelkast

Nieuwste handleidingen voor Koelkast