Netgear APS600Wv2 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Netgear APS600Wv2 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 168 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Installation Guide
Overview
The APS350W, APS600Wv2, APS920W, and APS2000W auxiliary power supplies (APSs)
are supported in the following M4350 series switch models:
• M4350-24F4V (SKU number XSM4328FV)
• M4350-24X4V (SKU number XSM4328CV)
• M4350-44M4X4V (SKU number MSM4352)
• M4350-24G4XF (SKU number GSM4328)
• M4350-48G4XF (SKU number GSM4352)
Each APS provides two bi-colored LEDs (DC OK LED and AC OK LED), which work
together to indicate the power supply status, as described in the following table.
DC OK LED
(Left LED)
AC OK LED
(Right LED)
Condition
Solid green Solid green DC output is present and voltage is good.
Blinking green Solid green AC power is present but DC output is for standby only.
Solid Red Solid green A power supply failure occurred and the APS will be
shut down.
Solid green Loss of AC power occurred or AC power is not present.Blinking red
Install an APS
In models with more than one power supply bay, you can install an additional APS.
1. Pull out the cover plate from the power module bay in which you want to insert the
additional APS.
2. Insert the APS into the power module bay, and gently push the APS into the bay.
CAUTION: When inserting the APS, do not use unnecessary force. Doing so
can damage the connectors on the back of the APS and on the midplane.
3. Connect the end of the power cord to the power receptacle on the APS.
4. Plug the AC power cord into a power source such as a wall socket or power strip.
When you apply power, the AC OK LED ands the DC OK LED on the APS lights. The
LED on the switch for the power supply bay also lights. If these LEDs do not light,
make sure that the power cord is plugged in and that the power source is good.
Auxiliary Power Supplies for the
M4350 Series Fully Managed Switches
APS350W, APS600Wv2, APS920W, and APS2000W
Package contents
• Auxiliary power supply
• Power cord (varies by region)
• Installation guide
Replace an APS
In models with more than one APS, the APSs are hot-pluggable.
1. If your switch functions with a single APS only, disconnect the power cord from the
APS and let the switch power down.
If your switch functions with more than one APS, you do not need to power down the
switch and you can perform a hot swap.
2. Remove the APS from the power module bay by doing the following:
a. Position the extraction handle perpendicular to the APS.
b. Insert your left index îť´nger into the extraction handle.
c. Use your left thumb to move the orange release latch to the left and keep it in the
release position.
d. Pull the extraction handle.
We recommend that you use your right hand to support the APS.
3. Insert the replacement APS into the power module bay, and gently push the APS into
the bay until the latch locks.
CAUTION: When inserting the APS, do not use unnecessary force. Doing so
can damage the connectors on the back of the APS and on the midplane.
4. Connect the end of the power cord to the power receptacle on the APS.
5. Plug the AC power cord into a power source such as a wall socket or power strip.
When you apply power, the AC OK LED ands the DC OK LED on the APS lights. The
LED on the switch for the power supply bay also lights. If these LEDs do not light,
make sure that the power cord is plugged in and that the power source is good.
May 2023
© NETGEAR, Inc., NETGEAR and the
NETGEAR Logo are trademarks of
NETGEAR, Inc. Any non‑NETGEAR
trademarks are used for reference
purposes only.
NETGEAR, Inc.
350 East Plumeria Drive
San Jose, CA 95134, USA
NETGEAR INTERNATIONAL LTD
Floor 6, Penrose Two,
Penrose Dock, Cork, T23 YY09, Ireland
Technical specications
Feature APS Model Speciîť´cations
AC input APS350W 100–127VAC, 5A, 50–60 Hz
200–240VAC, 2.5A, 50–60 Hz
APS600Wv2 100–127VAC, 9A, 50–60 Hz
200–240VAC, 5A, 50–60 Hz
APS920W 100–127VAC, 12A, 50–60 Hz
200–240VAC, 6A, 50–60 Hz
APS2000W 100–127VAC, 13A, 50–60 Hz
200–240VAC, 10A, 50–60 Hz
DC output APS350W +54.5VDC, 6.4A
APS600Wv2 +56 VDC, 11A
APS920W +54.5VDC, 16.88A
APS2000W +54.5 VDC, 18.35A @ 90-136 VAC
+54.5 VDC, 29.36A @ 180-220 VAC
+54.5 VDC, 36.7A @ 220-264 VAC
Dimensions (H x W x D) All models 1.6 x 2.9 x 7.3 in. (40 x 73 x 185 mm)
Operating temperature All models 23°F to 131°F (–5°C to +55°C)
Operating relative
humidity
All models 5% to 90% relative humidity
Operating altitude level All models Up to 16,404 feet (5,000 m)
Storage temperature All models –40°F to 158°F (–40°C to 70°C) at a
maximum rate of change of 68°F (20°C) per
hour
Storage altitude level All models Up to 49,859 feet (15,200 m)
MTBF All models Minimum MTBF at continuous operation
of 200,000 hours at 100% load and 77°F
(25°C), as calculated by Bell core Telcordia
SR-332- Issue 2.
Compliance (All Models)
Safety UL60950-1/CSA 60950-1 (USA / Canada)
IEC60950-1 (International)
UL62368-1/CSA 62368-1 (USA / Canada)
IEC62368-1 (International)
CB Certiîť´cate & Report, IEC60950-1
CB Certiîť´cate & Report, IEC62368-1
EN60950-1 (Europe)
Nordics -EMKO-TSE (74-SEC) 207/94
CE - Low Voltage Directive 2006/95/EC (Europe)
GB4943- CNCA Certiîť´cation (China)
EMC FCC /ICES-003 - Emissions (USA/Canada) Verication CISPR 22 – Emissions
(International)
EN55022 – Conducted & Radiated Emissions (Europe)
EN55024 - Immunity (Europe)
EN61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-8, 4-11
CE – EMC Directive 2014/30/EU (Europe)
VCCI (Japan)
AS/NZS CISPR 22 (Australia / New Zealand)
GB 9254 – (EMC) Certication (China)
GB 17625.1 - (Harmonics) CNCA Certiîť´cation (China)
Warranty
Visit the NETGEAR warranty page to view the warranty information for your new NETGEAR
device:
Support and Community
Visit netgear.com/support to get your questions answered and access the latest
downloads.
You can also check out our NETGEAR Community for helpful advice at
community.netgear.com.
Regulatory and Legal
Si ce produit est vendu au Canada, vous pouvez accéder à ce document en français
canadien Ă  netgear.com/support/download/. (If this product is sold in Canada, you
can access this document in Canadian French at netgear.com/support/download/.)
For regulatory compliance information including the EU Declaration of Conformity,
visit netgear.com/about/regulatory/. See the regulatory compliance document before
connecting the power supply. For NETGEAR’s Privacy Policy, visit
netgear.com/about/privacy-policy. By using this device, you are agreeing to NETGEAR’s
Terms and Conditions at netgear.com/about/terms-and-conditions. If you do not agree,
return the device to your place of purchase within your return period.
Do not use this device outdoors. If you connect cables or devices that are outdoors to the
switch, see kb.netgear.com/000057103 for safety and warranty information.
Applicable to 6 GHz devices only: Only use the device indoors. The operation of 6 GHz
devices is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation
of this device is permitted in large aircraft while îťµying above 10,000 feet. Operation of
transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications
with unmanned aircraft systems.
Australia:
www.netgear.com/au/
about/warranty/
Japan:
www.netgear.com/jp/
about/warranty/
China:
www.netgear.com/cn/
about/warranty/
All other countries: Visit
www.netgear.com/about/
warranty/
and click the îťµag to select
your country.
http://support.netgear.cn/China-RoHS


Product specificaties

Merk: Netgear
Categorie: Niet gecategoriseerd
Model: APS600Wv2

Heb je hulp nodig?

Als je hulp nodig hebt met Netgear APS600Wv2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Netgear

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd