Mustek PowerMust 1500 Handleiding

Mustek Diversen PowerMust 1500

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Mustek PowerMust 1500 (48 pagina's) in de categorie Diversen. Deze handleiding was nuttig voor 47 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/48
User Manual
Line Interactive UPS
Warranty & Service Information
Thanks for buying this Mustek UPS product.
Please follow the instructions in the product manual and if applicable the
software installation manual, to have the maximum use of your product.
Installing the software:
If you product comes with software you will find a CD Rom in the box containing
the software.
Please follow the instructions when installing the software.
You can download the software, manual and short reference manual at the
following site:
http://www.power-software-download.com/viewpower.html
Warranty:
As a manufacturer we provide a minimum of 1 year warranty on our product.
However for the exact warranty period and the warranty terms you should
contact your reseller as both the warranty period and the terms may vary per
Country / Region.
Problem solving:
Please check the chapter in your manual (hardware and software) on problem
solving.
Additionally:
Please check our website (www.Mustek.eu) regularly for updates of the software
as well as Frequent Asked Questions (FAQ).
If this not solve your problem please contact your reseller for advice.
Service and Maintenance:
If the product requires service or maintenance in the warranty period always
contact your reseller for the procedures. If outside the warranty period we advise
you to contact your reseller as well. In any case always make sure that service or
maintenance on the product are performed by a qualified technician.
User Manual
EN
WARNING: This is a category C2 UPS product. In a residential environment,
this product may cause radio interference, in which case the user many be
required to take additional measures.
You should have received the following items inside of package:
- UPS Unit - Quick Guide - Warranty card
Front Panel Overview: Rear Panel Overview:
400VA/600VA/800VA
1000VA/1500VA/2000VA
LED
UPS Status
LED
Alarm
UPS Status
●
The mains is normal
and UPS is operated
normally.
●Green
Off
The mains is normal
and UPS is operated
normally.
β˜…
Power failure occurs
and UPS is on battery
mode.
β˜…Yellow
Sounding
every 10
seconds
Power failure occurs
and UPS is on battery
mode.
β˜…
Low battery
β˜…Yellow
Sounding
every second
Low battery
β—‹
UPS is off.
β—‹Green
Off
UPS is off.
●
UPS fault
●Red
Continuously
sounding
UPS fault
●LED on β—‹ LED Off β˜… LED flashing
Operation Display
UPS Mode
LCD
Description
UPS Power on
When UPS is powered on, it will enter this
mode for 4 seconds.
AC Mode
When AVR is functioning, icon will flash
every second.
LCD information will be displayed in the
following order when LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload in AC
mode
icon will flash.
When overload occurs, alarm will beep every
0.5 second.
Battery Mode
When battery level is low, icon will
flash.
Alarm will beep every 10 seconds and LCD
information will be displayed in the following
order when LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload in battery
mode
icon will flash.
When overload occurs, alarm will beep every
0.5 second.
NOTE: If backlight shuts off, you may activate it by touching the screen.
Fault Code Table:
Fault condition
LCD
Solutions
Output short circuited
Disconnect short-circuited loads and restart the UPS again.
Overload fault
Disconnect all output loads and restart the UPS again.
Overcharge
Call for service immediately.
Bad or severely
discharged battery
Please replace the battery.
High output voltage
fault
Call for service immediately.
Over-temperature
1. Turn off the unit and wait for cooling.
2. Or remove excessive loads and wait for cooling.
If fault alarm occurs, please call for service immediately.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and
humidity range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS's cooling vents and avoid
exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space
heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment,
microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other
liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC
power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! With the installation of this equipment, it should be prevented that the sum of the leakage current
of the UPS to the connected consumer exceeds 3.5mA.
User Manual
 LCD Display
ο₯ Power switch
Power switch with LED
indicator
 AC input
ο‚€ Output receptacles
 Circuit breaker
ο‚‚ RJ-11
 USB (optional)
 RJ-45 (optional)
EN
EN
EN
4 hours
CAUTION: NEVER connect a laser printer or scanner to the UPS unit. This may
cause the damage of the unit.
Attention hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous
voltage still may be accessible through supply from battery. The battery supply should be therefore
disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service
work inside the UPS is necessary.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery
or batteries. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and high short circuit current. The following precaution
should be observed before replacing batteries:
1) Remove watches, rings, or other metal objects.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
Before installation, please make sure nothing inside of package is damaged. To protect your equipment
from power failure, be sure that power switch must be kept in the β€œON” position. Following below steps to
install your UPS unit.
❢
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the
UPS away from other units at least 20 cm to avoid interference. Do NOT operate the UPS where the
temperature and humidity is outside the specific limits. (Please check the specs for the limitations.)
❷
Connect to Utility and Charging
Plug in the AC input cord to the wall outlet. For the best results, suggest to charge the battery at least 4 hours
before initial use. The unit charges its battery while connecting to the utility.
❸
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS
unit, then devices connected to the UPS will be protected by UPS unit.
❹Connect Modem/Phone/Network for Surge Protection (Only for the model with RJ-11/RJ45)
Connect a single modem/phone line into surge-protected β€œIN” outlet on the back panel of the UPS unit. Connect
from β€œOUT” outlet to the computer with another phone line cable.
❺Connect Com. Port and Install Software (only for the model with RS-232/USB port)
To enable remote UPS shutdown/start-up and status monitoring, connect the communication cable from the
USB/RS-232 port and the other to the communication port of your PC. With the monitoring software installed,
you can schedule UPS shutdown/start-up and monitor the UPS status.
❻
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch.
MODEL
400
600
800
CAPACITY
400VA/240W
600VA/360W
800VA/480W
Input Voltage
220/230/240VAC
Input Voltage Range
162-290 VAC
Output Voltage Regulation
Β± 10 % (Bat. mode)
Frequency Range (Batt. Mode)
50Hz +/-1 Hz
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type & No
12V/4.5Ahx1
12V/7Ahx1
12V/9Ahx1
Charging Time
4-6 hours recover to 90% capacity
Dimension (DxWxH) mm
LED: 279 x 101 x 142 / LCD: 300 x 101 x 142
Net Weight (kgs)
LED
3.55
4.2
4.9
LCD
3.7
4.4
5.0
Humidity
0-90% RH @ 0-40Β°C non-condensing)
Noise Level
Less than 40dB
MODEL
1000
1500
2000
CAPACITY
1KVA/600W
1.5KVA/900W
2KVA/1200W
Input Voltage
220/230/240VAC
Input Voltage Range
162-290 VAC
Output Voltage Regulation
Β± 10 % (Bat. mode)
Frequency Range (Batt. Mode)
50Hz +/-1 Hz
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type & No
12V/7Ah x 2
12V/9Ah x 2
12V/9Ah x 2
Charging Time
4-6 hours recover to 90% capacity
Dimension (DxWxH)
320 x 130 x 182
Net Weight (kgs)
8.2
10.4
11
Humidity
0-90% RH @ 0-40Β°C (non-condensing)
Noise Level
Less than 40dB
Problem
Possible Cause
Solutions
No LED display on the front
panel.
Low battery.
Charge the UPS at least 6 hours.
Battery fault.
Replace the battery with the same type of
battery.
The UPS is not turned on.
Press the power switch again to turn on
the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overload.
Remove some loads first. Before
reconnecting equipment, please verify
that the load matches the UPS capability
specified in the specs.
When power fails, back-up time
is shorten.
The UPS is overload.
Remove some critical load.
Battery voltage is too low.
Charge the UPS at least 6 hours.
Battery defect. It might
be due to high
temperature operation
environment, or improper
operation to battery.
Replace the battery with the same type of
battery.
The mains is normal but the
unit is on battery mode.
Power cord is loose.
Reconnect the power cord properly.
User Manual
EN
EN


Product specificaties

Merk: Mustek
Categorie: Diversen
Model: PowerMust 1500

Heb je hulp nodig?

Als je hulp nodig hebt met Mustek PowerMust 1500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Diversen Mustek

Handleiding Diversen

Nieuwste handleidingen voor Diversen