DreamStation
Heated Humidier
© 2018 Koninklijke Philips N.V. All rights reserved.
Table of Contents
Intended Use 1 ...........................................................................................................................................................
Warnings 1 ..................................................................................................................................................................
Cautions 1 ...................................................................................................................................................................
Contraindications 2 ..................................................................................................................................................
Symbols Glossary 2 ...................................................................................................................................................
System Overview 2 ...................................................................................................................................................
System Features and Contents 3 ...........................................................................................................................
How to Contact Philips Respironics 3 .................................................................................................................
Connecting to the Therapy Device 4 ....................................................................................................................
Connecting the Tubing .......................................................................................................................................... 4
Daily Use.................................................................................................................................................................. 5
Disconnecting the Tubing ..................................................................................................................................... 6
Disconnecting the Therapy Device 7 ....................................................................................................................
Checking the Humidier Lid Seal .......................................................................................................................7
Home Cleaning Instructions: Water Tank 8 ........................................................................................................
Home Cleaning Instructions: Humidier Base ................................................................................................8
Home Cleaning Instructions: Heated Tubing 8 ....................................................................................................
Hospital and Institution Disinfection 8 .................................................................................................................
Service 9 ......................................................................................................................................................................
Traveling with the System 9 ....................................................................................................................................
Disposal 9 ....................................................................................................................................................................
Troubleshooting 10 ...................................................................................................................................................
DreamStation Heated Humidier Specications ..........................................................................................12
Heated Tubing Specications .............................................................................................................................12
Limited Warranty Back Page ...................................................................................................................................
1
Caution: U. S. federal law restricts this device to sale by or on the order of a physician.
Intended Use
The DreamStation Heated Humidier is an accessory for the Philips Respironics DreamStation therapy devices to
provide moisture to the patient circuit. It is intended for use in spontaneously breathing patients weighing over 30 kg
(66 lbs), in the home or hospital/institutional environment, who use mask-applied positive pressure ventilation therapy.
Warnings
Use the humidier only for its intended use as described in this manual. Use only with masks and connectors recommended by
Philips Respironics.
Periodically inspect the humidier for signs of wear or damage. Never operate the humidier if any parts are damaged, if it is not
working properly, or if the humidier has been dropped or mishandled. Do not use the humidier if the water tank is leaking or
damaged in any way. Have any damaged parts replaced before continuing use.
Periodically inspect the therapy device power cord for signs of wear or damage. If it becomes worn or damaged, contact Philips
Respironics or your home care provider for a replacement.
The humidier must always be positioned below the breathing circuit connection at the mask. The humidier must be level for
proper operation.
Allow the humidier heater plate and water to cool down for approximately 15 minutes before removing the water tank. A burn
may result from: touching the heater plate, coming in contact with the heated water, or touching the tank pan.
This equipment is not suitable for use in the presence of a ammable anesthetic mixture with air or with oxygen or nitrous oxide.
When installing the water tank, do not allow any water to spill into the humidier or therapy device.
If you notice any unexplained changes in the performance of this device, if it is making unusual or harsh sounds, if it has been
dropped or mishandled, or if the enclosure is broken, disconnect the power cord from the therapy device and discontinue use.
Contact your home care provider.
Before cleaning the humidier, always remove from the therapy device.
Empty and clean the water tank daily to prevent mold and bacteria growth.
Repairs and adjustments must be performed by Philips Respironics-authorized service personnel only. Unauthorized service could
cause injury, invalidate the warranty, or result in costly damage.
Do not use any accessories, detachable parts, and materials not recommended by Philips Respironics. Incompatible parts or
accessories can result in degraded performance.
Note: Please see the “Limited Warranty” section of this manual for information on warranty coverage.
Cautions
Do not place the humidier directly onto carpet, fabric, or other ammable materials.
Do not place the device in or on any container that can collect or hold water. Take precautions to protect furniture from water
damage.
Do not ll the water tank above the maximum ll line. If the water tank is overlled, water may leak into the therapy device,
humidier, or onto your furniture. Damage to the humidier or therapy device may occur.
Use only room temperature distilled water in the tank. Do not put any chemicals or additives into the water. Possible airway
irritation or damage to the water tank may result.
Remove the tank, empty all water, and replace the empty tank before transporting the humidifier base.
Do not attempt to ll the water tank while it is still inside the humidier.
To avoid spilling, do not disconnect the humidier from the therapy device with water in the tank. Remove the water tank from
the humidier before disconnecting the therapy device.
Do not turn the humidier on without the water tank installed. The Humidier setting must remain “off” if there is no water in
the water tank.
Do not move the humidier while the water tank has water in it.
Use a mild liquid dishwashing detergent only for either hand washing or when using a dishwasher.
Only the hospital and institution cleaning procedures listed in this manual are recommended by Philips Respironics. Use of other
cleaning and disinfecting processes, not specied by Philips Respironics, may affect the performance of the product.


Product specificaties