Milwaukee LDM 50 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Milwaukee LDM 50 (18 pagina's) in de categorie Afstandsmeter. Deze handleiding was nuttig voor 50 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/18
1ENGLISH
I
MPORTANT SAFETY INSTRUCTIONS
Do not use the product before you have studied
the Safety instructions and the User Manual.
Laser Classi cation
WARNING:
It is a Class 2 laser product in accordance
with EN 60825-1:2007.
Labeling
We have supplied you with an adhesive label in your language
and now request that you please apply this in place of the
English text on the specifi cation plate before fi rst
commissioning the machine.
447701 01
XXXXXX MJJJJ
WARNING:
Avoid direct eye exposure. The laser beam can cause ash
blindness.
Do not stare into the laser beam or direct it towards other
people unnecessarily.
Don't dazzle other individuals.
WARNING:
Do not operate the tool around children or allow children to
operate the tool.
The refl ective surface could refl ect the beam back at the
operator or other persons.
Keep extremities in a safe distance from the moving parts.
Carry out periodic test measurements. Particularly before,
during and after important measurements.
Watch out for erroneous measurements if the product is
defective or if it has been dropped or has been misused or
modifi ed.
WARNING: Use of controls, adjustments, or the performance
of procedures other than those specifi ed in the manual may
result in hazardous radiation exposure.
The laser distance measurer has limits of use. (Refer to the
“Technical data” section). Attempts to measure outside the
maximum and minimum range will cause inaccuracy. Use in
adverse conditions including too hot, too cold, very bright
sunlight, rain, snow, fog, or other vision restricting conditions
will result in inaccurate readings.
When the laser distance measurer is brought into a warm
environment from very cold conditions, or vice versa, allow it to
come to the surrounding temperature before use.
Always store the laser distance measurer indoors, avoid
exposing the tool to shock, continuous vibration or extreme
temperatures.
Always keep the tool away from dust, liquids and high humidity.
These may damage internal components or affect accuracy.
Do not use aggressive cleaning agents or solutions. Use only a
clean, soft cloth for cleaning.
Avoid heavy impact to or dropping of the measuring tool. The
accuracy of the tool should be checked before use if it has
been dropped or subjected to other mechanical stresses.
Any repair required on this laser product should be performed
only by authorised service personnel.
Do not operate the product in explosion hazardous areas or in
aggressive environments.
Only use chargers recommended by the manufacturer to
charge the batteries.
Flat batteries must not be disposed of with household
waste. Care for the environment and take them to the
collection points provided in accordance with national or
local regulations. The product must not be disposed with
household waste. Dispose of the product appropriately in
accordance with the national regulations in force in your
country. Adhere to the national and country specifi c regulations.
Please contact your local authority or your dealer for how to
dispose of batteries properly.
European Conformity Mark
CONTENTS
I
mportant safety instructions ...................................................1
Specifi ed Conditions of Use ...................................................2
Error Code Table ....................................................................2
Overview.................................................................................3
Change batteries ....................................................................4
Corner Pin ..............................................................................4
Belt Clip ..................................................................................4
Function Switch, Measuring Reference, Pythagoras..............5
Single Distance Measuring .....................................................6
Permanent / Minimum-Maximum Measuring ..........................7
Add / Subtract Measuring .......................................................8
Area Measuring ......................................................................9
Volume Measuring ................................................................10
Indirect Measuring (Pythagoras 1) .......................................11
Indirect Measuring (Pythagoras 2) .......................................12
Indirect Measuring (Pythagoras 3) .......................................13
Wall Area Measuring (Scenario 1) ......................................14
Wall Area Measuring (Scenario 2) ......................................15
Timer ....................................................................................16
Memory .................................................................................16
Basic Description on example of Area measuring (1)...........17
Basic Description on example of Area measuring (2)...........18
2ENGLISH
TECHNICAL DATA
Dust and Water resistance IP54
Receiving Lens 14 mm
Focus 35 mm
Maximum Measuring Range 50 meters (Tolerance : 55m)
Minimum Measuring Range 0.05 meters
Absolute Accuracy @ < 10m ± 1.5 mm (Max)
Repeatability Accuracy @ < 10m ± 1.5 mm (Max Typical, 2σ)
Repeatability Accuracy @ > 10m Increase ± 0.25 mm / meter (Max Typical, 2σ)
Measurement Time 0.5 s
Display Type LCD ( 22.7 mm x 31 mm )
Power Type AAA 2x (Alkaline Battery)
Battery Life 10000 (Single Measure)
Laser Output Power 0.6 mW ~ 0.95 mW (Class 2, 650nm )
Laser Spot Size 25 x 30 mm @ 16 m (Max)
Laser Radiation Vertical Angle +1 degree
Laser Radiation Horizontal Angle ±1 degree
Device auto off time 180 seconds
Laser auto off time 30 seconds
Operating Temperature Range -10°C to +50°C
Storage Temperature Range -25°C to +70°C
Weight without Battery 80 g
SPECIFIED CONDITIONS OF USE
The laser distance measurer can be used for measuring distances and tilts.
Do not use this product in any other way as stated for normal use.
ERROR CODE TABLE
Code Description Solution
Err01 Out of measuring range Measure in a proper range
Err02 Refl ect signal is too weak Choose a better surface
Err03 Out of display range (max value:
99.999) e.g. result of area or volume
is out of display range
Check and verify values and steps
are correct
Err04 Pythagorean calculation error Check and verify values and steps
are correct
Err05 Battery is low Install new batteries
Err06 Out of working temperature Measure in an environment with the
specifi ed working temperature
Err07 Ambient light is too strong Measure in a darker place (shadow
target)
3ENGLISH
OVERVIEW
ON / MEASURE
On
Measure
Continuous Measurement (push 2 sec)
+ Min / Max Function
ADD / SUBSTRACT
Add value
Subtract value
AREAS / VOLUMES
Area (push 1x)
Volume (push 2x)
Indirect Surface Measurement (push 3x / 4x))
POWER
On
Off (push 2 sec)
Clear
PYTHAGORAS
Pythagoras 1 (push 1x)
Pythagoras 2 (push 2x)
Pythagoras 3 (push 3x)
MEMORY
Timer 3-15 sec (push 1x)
Memory 1-20 (push 1x, 2 sec)
Read memory (push repeated)
CHANGE POINT OF MEASURE
Front
Back (Standard automatical)
Corner pin
Single Pythagoras
Height difference
Minimum / Maximum for continuous Measure
Area/ Volume
Indirect Surface Measurement
Battery Status
Memory
Timer
Continuous measure mode
Addition / Subtraction
Main Value
Among Values
Measuring Reference
Normal Measuring Mode


Product specificaties

Merk: Milwaukee
Categorie: Afstandsmeter
Model: LDM 50

Heb je hulp nodig?

Als je hulp nodig hebt met Milwaukee LDM 50 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afstandsmeter Milwaukee

Handleiding Afstandsmeter

Nieuwste handleidingen voor Afstandsmeter