OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
Contact Temp Meter
Dispositif de Mesure de la Température de Contact
Termómetro por Contacto
Cat. No.
No de Cat.
2270-20
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
2 3
FUNCTIONAL DESCRIPTION
1. Display
2. Power ON/OFF
3. °C or °F selector
4. Hold button
5. Mode selector
6. START STOP button
7. MIN MAX AVG button
8. T1 and T2 inputs
9. Battery life indicator
10. Primary measurement
11. Elapsed time total
12. Time MIN MAX
13. Hold indicator
14. Secondary measurement
15. °C or °F indicator
16. Delta T1-T2 indicator
Speci cations
Contact temp range: -200°C to 1372°C (-328°F to 2501°F)
Accuracy
For ambient temperatures 18°C to 28°C (64°F to 82°F)
Measurements from -100°C to 1372°C (-148°F to 2501°F)
± (0.1% of reading + 0.7°C)/(0.1% of reading +1.3°F)
Measurements from -200°C to -100°C (-328°F to -148°F)
± (0.4% of reading +0.7°C)/(0.4% of reading +1.3°F)
Temperature Coef cient
Measurements from -100°C to 1372°C (-148°F to 2501°F)
(0.01% of reading + 0.05°C) per degree C outside 18°C to 28°C ambient
(0.0056% of reading +0.05°F) per degree F outside of 64°F to 82°F ambient
Measurements from -200°C to -100°C (-328°F to -148°F)
(0.04% of reading + 0.05°C) per degree C outside 18°C to 28°C ambient
(0.022% of reading +0.05°F) per degree F outside of 64°F to 82°F ambient
Contact temp display resolution: 0.1°C/°F
K-Type Probe temp range: -60°C to 200°C (-76°F to 392°F)
K-Type Probe temp input accuracy: ±1.1°C or ±0.4% of reading, whichever is greater
Drop: 1 meter
Operating temperature: -10°C to 50°C (14°F to 122°F)
Storage temperature: -40°C to 60°C (-40°F to 140°F)
Relative humidity: 10 to 90% RH non-condensing at <30°C (<86°F) ambient
Battery: 3 AA batteries, LR6, 4.5V DC
Battery life: Greater than 80 hrs with all functions
Safety Compliances .... EN61326-1,2; IEC61000-3-2,3; IEC61000-4-2,3,4,5,6; CISPR11; FCC Part 15
Certi cations .... CE
IMPORTANT SAFETY INSTRUCTIONS
PERSONAL SAFETY
WORK AREA SAFETY
BATTERY USE AND CARE
SERVICE
WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS. Failure to follow
the warnings and instructions may result in electric shock, re and/or serious injury.
Save these instructions - This operators manual contains important safety and operating
instructions for the MILWAUKEE Contact Temp Meter. Before using, read this operator’s
manual and all labels on the meter.
Keep children and bystanders away while
operating meter. Store idle Contact Temp
Meters out of the reach of children and do not
allow persons unfamiliar with the tool or these
instructions to operate them.
Avoid dangerous environments. Do not use in
rain or snow. Do not immerse meter in water or
allow water to ow into the meter. Do not use in
the presence of explosive atmospheres (gaseous
fumes, dust or ammable materials) because
sparks may be generated when inserting or remov-
ing batteries, possibly causing re.
Stay alert, watch what you are doing and use
common sense when operating meter. Do not
use while you are tired or under the in uence
of drugs, alcohol or medication. A moment of
inattention may result in serious personal injury.
Do not overreach. Keep proper footing and
balance at all times. This enables better control
in unexpected situations.
Never connect the probe to an energized circuit.
This tool is designed to be powered by
3-AA batteries properly inserted into the
MILWAUKEE meter. Do not attempt to use with
any other voltage or power supply.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix
brands (or types within brands) of batteries.
Do not mix rechargeable and non-rechargeable
batteries.
Install batteries according to polarity (+ / –)
diagrams.
Properly dispose of used batteries immedi-
ately.
Do not incinerate or dismantle batteries.
Under abusive conditions, liquid may be eject-
ed from the battery, avoid contact. If contact
accidentally occurs, ush with water. If liquid
contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation
or burns.
Have your serviced by a qualimeter ed repair
person using only identical replacement parts.
This will ensure that the safety of the tool is main-
tained.
Do not disassemble. Incorrect reassembly may
result in the risk of electric shock or re. If it is dam-
aged, take it to a MILWAUKEE service facility.
Store in a cool, dry place. Do not store where
temperatures may exceed 140°F (60°C) such as
in direct sunlight, a vehicle or metal building during
the summer.
Do not remove or deface labels. Maintain labels
and nameplates. These carry important information.
If unreadable or missing, contact a MILWAUKEE
service facility for a free replacement.
SYMBOLOGY
Read Operator’s Manual
Earth
Danger, Warning, or Caution -
Consult the operators manual for
additional safety information.
Battery compartment
European Conformity Mark
Do not dispose of this product as
unsorted municipal waste.
11
12
13
14
15
16
4
2
1
3
5
6
7
8
9
10
4 5
OPERATION
Making a Measurement
Insert the probe into the input. Two probes can be
used simultaneously.
Press and hold the button to turn the meter on.
The display will continue to update the contact
temperature while the temperature probe reaches
thermal equilibrium with the object being measured.
The display will switch to low backlight mode
5 minutes after the last button is pressed. The
meter will automatically power off after an additional
25 minutes if no buttons are pressed.
If the low battery life indicator appears , the
meter will automatically power off 5 minutes after
the last button is pressed (replace the batteries as
soon as possible).
Press the button or button to start the
timer and begin tracking the maximum, minimum
and average temperatures over time.
When the timer is activated the auto power off time
is extended to 30 hours.
Press the button to toggle through the
minimum, maximum, and average readings. The
measurement time readings also toggle through
the minimum, maximum, and average.
Press the button to turn off the timer and
stop tracking minimum, maximum and average
temperatures.
Press the button to toggle between Celsius
(°C) and Fahrenheit (°F).
Press the button to hold or release the dis-
played readings.
Press the button to change what is displayed
in the primary and secondary measurements.
Press and hold the button to turn the meter off.
WARNING Never connect the probe
to an energized circuit.
MAINTENANCE
WARNING To reduce the risk of per-
sonal injury and damage, never immerse your
tool in liquid or allow a liquid to ow inside it.
WARNING To reduce the risk of injury,
always remove the batteries from the tool
before performing any maintenance. Never
disassemble the tool. Contact a MILWAUKEE
service facility for ALL repairs.
Cleaning
Clean dust and debris from tool. Keep tool clean, dry
and free of oil or grease. Use only mild soap and a
damp cloth to clean the tool since certain cleaning
agents and solvents are harmful to plastics and other
insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
gents containing ammonia. Never use ammable or
combustible solvents around tools.
Repairs
For repairs, return the tool to the nearest service
center listed on the back cover of this operator's
manual.
Maintaining Tool
Keep your tool in good repair by adopting a regular
maintenance program. After six months to one year,
depending on use, return the tool to a MILWAUKEE
service facility for repairs.
If the tool does not start or operate at full power
with new batteries, clean the contacts on the battery
door. If the tool still does not work properly, return
the tool to a service facility for repairs.MILWAUKEE
ACCESSORIES
For a complete listing of accessories refer to your
MILWAUKEE Electric Tool catalog or go online
to www.milwaukeetool.com. To obtain a catalog,
contact your local distributor or service center.
WARNING Always remove batteries
before changing or removing accessories. Only
use accessories speci cally recommended for
this tool. Others may be hazardous.
ASSEMBLY
WARNING To avoid an electrical
hazard, turn off the tool and disconnect the
thermocouples before replacing batteries.
Loading/Changing the Batteries
Replace batteries when the Low Battery indicator
is displayed.
1. Turn meter OFF and disconnect the probes.
2. Unscrew and remove battery door.
3. Insert three (3) AA batteries, according to the
polarity marked in the battery compartment
4. Close the battery door and tighten screws
securely.