Microchip VSC6802 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Microchip VSC6802 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Microsemi makes no warranty, representation, or guarantee regarding the information contained herein or the suitability of its products and services for any particular purpose, nor does Microsemi assume any liability
whatsoever arising out of the application or use of any product or circuit. The products sold hereunder and any other products sold by Microsemi have been subject to limited testing and should not be used in conjunction
with mission-critical equipment or applications. Any performance specifi cations are believed to be reliable but are not verifi ed, and Buyer must conduct and complete all performance and other testing of the products, alone
and together with, or installed in, any end-products. Buyer shall not rely on any data and performance specifi cations or parameters provided by Microsemi. It is the Buyer’s responsibility to independently determine suitability
of any products and to test and verify the same. The information provided by Microsemi hereunder is provided “as is, where is” and with all faults, and the entire risk associated with such information is entirely with the Buyer.
Microsemi does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other IP rights, whether with regard to such information itself or anything described by such information. Information provided in
this document is proprietary to Microsemi, and Microsemi reserves the right to make any changes to the information in this document or to any products and services at any time without notice.
I/O Layer
Chip Interface Layer
Switch PHY Switch
Packet Control Layer 2
Quality of
Service Security
Initialization
Trace
Layer
OS
Layer
Port Control
Miscellaneous
Application Interface Layer
Highlights
Robust, user-friendly, and widely deployed
Operating system independent
Supports all Microsemi Ethernet switches
and PHYs
Applications
Enterprise, Small-Medium Enterprise (SME)
switches
Carrier Ethernet switches and routers
Industrial Ethernet switches
Microsemi Uni ed API delivers a comprehensive, user-friendly, and
robust function library that supports all Microsemi Ethernet switch and
PHY products.
The VSC6802API uni ed Application Programming Interface (API)
provides a comprehensive, user friendly, and robust function library
that supports all Microsemi Ethernet switch, MAC, PHY, and Optical
Transport Network (OTN) Mapper products. The VSC6802API is
portable to any Operating System (OS) and was developed with 32-
bit CPUs as intended targets. The driver software was developed in
standard C and supports multi-instance device targets.
The VSC6802API package includes:
• Driver software in standard C
• Application example and documentation
The architecture of the API includes fi ve different layers:
• Application Interface Layer (function groups)
• Chip Interface Layer (register mappings)
• I/O Layer (register access)
• OS Layer (Linux, VxWorks, eCos)
• Trace Layer
VSC6802API
Application Programming Interface (API) for Microsemi Ethernet Switches and PHYs
Microsemi Corporation (Nasdaq: MSCC) offers a comprehensive portfolio of semiconductor and system solutions for com-
munications, defense and security, aerospace, and industrial markets. Products include high-performance and radiation-
hardened analog mixed-signal integrated circuits, FPGAs, SoCs, and ASICs; power management products; timing and
synchronization devices and precise time solutions; voice processing devices; RF solutions; discrete components; enter-
prise storage and communications solutions, security technologies, and scalable anti-tamper products; Ethernet solutions;
Power-over-Ethernet ICs and midspans; custom design capabilities and services. Microsemi is headquartered in Aliso Viejo,
California, and has approximately 4,800 employees worldwide. Learn more at www.microsemi.com.
Microsemi Corporate Headquarters
One Enterprise, Aliso Viejo, CA 92656 USA
Within the USA: +1 (800) 713-4113
Outside the USA: +1 (949) 380-6100
Sales: +1 (949) 380-6136
Fax: +1 (949) 215-4996
email: sales.support@microsemi.com
www.microsemi.com
©2013–2016 Microsemi Corporation. All rights reserved. Microsemi and the Microsemi logo are registered trademarks of Microsemi Corporation. All other trademarks
and service marks are the property of their respective owners.
VPPD-03406. 1.1. 4/16
Basic Functions
Device initialization
Port map setup
Port reset and confi guration
Port status polling and confi guration based on auto-negotiation
Statistics
Trace system integration
Board-speci c register access and port mapping
Advanced Functions
Quality of Service (QoS) confi gurations
CPU interface functions for packet control
Port fi lters and access control lists
Layer 2 confi gurations
Stacking confi gurations
MEF EVC setup
Synchronization
1588v2 timestamping API
MPLS-TP
Key Specifi cations
Source code in standard C
Portable to any operating system (eCos, Linux, VxWorks)
Portable to 32-bit CPUs such as MIPS and ARM
Supports all Microsemi Ethernet switches and PHYs
Related Products
Visit www.microsemi.com for information about these related
products:
Microsemi Carrier Ethernet Switch Engines
Microsemi Enterprise Ethernet Switches
Microsemi Gigabit Ethernet and 10 Gigabit Ethernet PHYs
VSC6802API
Application Programming Interface (API) for Microsemi Ethernet Switches and PHYs


Product specificaties

Merk: Microchip
Categorie: Niet gecategoriseerd
Model: VSC6802

Heb je hulp nodig?

Als je hulp nodig hebt met Microchip VSC6802 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Microchip

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd