IMS 300/600/1000/1500/2500 (12/24V) 150/
Modified Sine Wave Inverter
User Manual
IMPORTANT NOTICE:
This product is not intended to be use by children or persons in poor health without
supervision. Please read this manual thoroughly before use.
This manual is written for below models:
652.000UK IMS150- –12
652.001UK IMS150- –24
652.002UK IMS300- –12
652.003UK IMS300- –24
652.004UK IMS600- –12
652.005UK IMS600- –24
652.006UK IMS1000- –12
652.007UK IMS1000- –24
652.008UK IMS1500- –12
652.009UK IMS1500- –24
652.010UK IMS2500- –12
652.011UK IMS2500-–24
CAUTION:
Each model is design to work up to its maximum rated power load.
Please check carefully to ensure applications used are within the rated power range.
Any attempt of misuse to overload will trigger the overload protection and may cause
damage to both unit and application used. Mercury will not be responsible for any
damaged caused by misusage of the product
WARNING
Contain high voltage and high current! Do not open or
attempt to repair yourself!
User Manual
INTRODUTION:
Thank you for choosing this Modified Sine Wave Inverter. This inverter is capable of converting DC power
input to AC power output that has similar output signal wave as normal domestic mains. Unlike pure sine
wave inverters, modified sine wave inverter is not recommended for powering voltage sensitive or
inductive equipment. For inductive load such as fluorescent light, acoustic equipment and equipment
contain motor such as fan and compressor, we recommend to use our pure sine wave inverter instead.
Below shows the differences in output voltage waveform between pure and modified output:
PRODUCT LAYOUT:
User Manual
FRONT PANEL:
- ON/OFF SWITCH – rocker switch to switch unit on and off
- POWER INDICATOR solid green LED indicates unit has been switched on –
- FAULT INDICATOR solid on or flashing red LED indicates fault has occurred, –
refer to fault code for interpretation
- USB POWER SOCKET 5V 1.0A USB power supply socket for charging smart phone camera etc –
- UK AC MAINS SOCKET output UK mains socket provide 230Vac 50Hz mains power –
- GROUND CONNECTION star washer and nut for ground connection to the outer case (normally –
connected to the vehicle chassis)
BACK PANEL:
- INPUT BATTERY NEGATIVE CONNECTION battery input connection to connect negative output –
of the DC power source
- INPUT BATTERY POSITIVE CONNECTION battery input connection to connect positive output of –
the DC power source
- FUSES location of the fuses –
- FAN DUCT fan for cooling - do not obstruct –
Temperature and load controlled multi-speed cooling fan:
The cooling fan is designed to run at a speed in proportion to the load, this minimises the running noise
and extend fan life.
- At load lower than 40% or inner temperature less than 30Β°C the fan will not operate
- At load between 40% - 60% the fan will operate at 40% of its maximum speed
- At load between 60% - 80% the fan will operate at 60% of its maximum speed
- At load between 80% - 100% the fan will operate at 80% of its maximum speed
- At 100% load or inner temperature exceeds 45Β°C the fan will operate at 100% of its maximum
speed
INSTALLATION:
Location it is important to for the location of the inverter to meet below requirements: –
- Dry environment where there should be no risk of the inverter coming into contact with water
- A cool shaded environment where temperature should be 0Β°C 40Β°C, –
not to be placed near any heat source and avoid direct sunlight
- A well-ventilated area, minimum clearance of two inches should be allowed in front of the
ventilation duct and fan. Please ensure free flow of air around the unit, if the unit is used to its full
load, an external fan may be used to aid the cooling of the unit
- Not to be place in the same compartment as the battery or together with flammable substances
- Avoid dusty environments, dust can cause blockage of airflow within the inverter
and cause the unit to overheat
- Avoid using long input cable run as input voltage can be affected by cable resistance and heat