Item ref: 600.103UK
CMT01
Clamp-on Digital Multimeter
User Manual
600.103 CMT01 User Manual UK
Please read this manual thoroughly and
ensure all contents are fully understood
before using the apparatus.
Warning
To avoid possible electric shock or pers l injury, and to avoid possible ona
damage to the tester or to the equipment under test, adhere to the se
following rules:
Before using the tester inspect the case. Do not use the tester if it is
damaged or the case (or part of the case) is removed. Look for cracks
or missing plastic. Pay attention to the insulation around the
connectors.
Inspect the test leads for damaged insulation or exposed metal.
Check the test leads for continuity.
Do not apply more than the rated voltage, as marked on the tester,
between the terminals or between any terminal and grounding.
The rotary switch should be in the right position and no changeover of
range shall be made during measurement is conducted to prevent
damage.
When the tester is working at an effective voltage over in DC or 60V
30Vrms in AC, special care should be taken for there is danger of
electric shock.
Use the proper terminals, function, and range for your measurements.
Do not use or store the tester in an environment of high temperature,
humidity, explosive, flammable, damp or of a strong magnetic field.
The performance of the tester may deteriorate after being exposed to
any of these elements.
When using the test leads, keep your fingers behind the finger guards.
Disconnect circuit power and discharge all high- ltage capacitors vo
before testing resistance, continuity, diodes.
600.103 CMT01 User Manual UK
Replace the battery as soon as the battery indicator appears. With a
low battery, the meter may produce false readings that can lead to
electric shock and personal injury.
Remove the connection between the testing leads and the circuit being
tested and turn the meter power off before opening the meter case.
The internal circuit of the meter shall not be altered at will to avoid
damage of the meter and any accident.
A soft cloth and mild de rgent should be used to clean the surface of te
the tester on a regular basis. No abrasive and solvent should be used
to prevent the surface of the tester from corrosion or damage.
The tester is suitable for indoor use only.
Turn the tester power off when i is not in use and take out the battery t
when not using for a long time. Check the battery regularly; replace the
battery immediately if any signs of leaking appear. Battery acid will
damage the tester.
General Specifications
Max display: LCD (1999 co t) 46 x 15mm un
Polarity: Automatic, indicated minus, assumed plus
Measure method: double integral A/D switch implement
Sampling speed: 2 times per second
Over-load indication: “1” is displayed
Operating Environment: 0 - , at <80%RH ºC 40ºC
Storage E ironment: - - , at <85%RH nv 10ºC 50ºC
Power: dc (1 x PP3 battery supplied) 9V
Low battery indication: “ ”
Dimensions: 230 x 68 x 37mm
Weight 203 : g


Product specificaties

Merk: Mercury
Categorie: Niet gecategoriseerd
Model: CMT01

Heb je hulp nodig?

Als je hulp nodig hebt met Mercury CMT01 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Mercury

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024
Festo

Festo CRVZS-5 Handleiding

21 November 2024