150W Single Output DC DC Converter-
SD-150
series
Model: SD- D-150 24 Test Report 1 / 3
MODEL:
:
:
::SD- D- 150 24
OUTPUT FUNCTION TEST
NO
T EST ITEM
SPECICATION
TEST CONDITION
VERDICT
1 RIPPLE & NOISE p-V1: 150 mV p (Max )
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
V1: 20 p-mV p (Max )
P
2 OUTPUT VOLTAGE
ADJUST RANGE
CH1: 23 V V~ 30 I/P: 115 VAC
O/P:MIN LOAD
Ta:25
℃
21.77V~ 32.75 V
P
3 OUTPUT VOLTAGE
TOLERANCE
V1: 1 -1 % %~ (Max)
I/P:85VAC / 132 VAC
O/P:FULL/ MIN LOAD
Ta:25℃
V1: 0.36 0. -%~ 36 %
P
4 LINE REGULATION V1: 0.3 - % %~ 0.3 (Max)
I/P:85VAC / 132 VAC
O/P:FULL LOAD
Ta:25℃
V1: 0.05 -0. % %~ 05
P
5 LOAD REGULATION 3 -V1: 0. %~ 0.3 % (Max)
I/P: 115 VAC
O/P:FULL ~MIN LOAD
Ta:25℃
V1: 0.2 - 2 % %~ 0.
P
6 SET UP TIME
2000 ms (Max)
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
877ms
P
7 RISE TIME 50 ms (Max)
I/P: 115 VAC
O/P:FULL LOAD
Ta:25
℃
4.7 ms
P
8 HOLD UP TIME 24ms I/P: 115 VAC
O/P:FULL LOAD
Ta:25
℃
34.2ms
P
9 OVER/UNDERSHOOT TEST + < 5% I/P: 115 VAC
O/P:FULL LOAD
Ta:25
℃
TEST: <5 %
P
10 DYNAMIC LOAD -p V1: 2400 mVp I/P: 115 VAC
O/P:FULL /Min LOAD
90%DUTY/1KHZ
Ta:25℃
483 -p mVp
P
INPUT FUNCTION TEST
NO
T EST ITEM
SPECICATION
TEST CONDITION
VERDICT
1 INPUT VOLTAGE RANGE 85VAC~ 132 VAC
72VDC~ 144 VDC
I/P:TESTING
O/P:FULL LOAD
Ta:25℃
82 VAC~ 132 VAC
71.8VDC~ 144 VDC
P
I/P:
- -3 VLOW LINE V= 82 AC
- 1 VHIGH LINE+ 5%= 151 AC
LOW-LINE DC- V0.2V= 71.8
- HIGH LINE+5%= 151VDC
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10M IN
( AC POWER ON/OFF NO DAMAGE )
TEST: OK
2 EFFICIENCY 82% (TYP) I/P: 115 VAC
O/P:FULL LOAD
Ta:25
℃
82.9 %
P
150W Single Output DC DC Converter-
SD-150
series
Model: SD- D-150 24 Test Report 2 / 3
3 INPUT CURRENT 2.1 A(TYP) I/P: 96 VDC
O/P:FULL LOAD
Ta:25℃
I = 1.8A
P
4 INRUSH CURRENT 22.5A I/P: 96 VDC
O/P:FULL LOAD
Ta:25
℃
I = 22.5A
P
5 LEAKAGE CURRENT <0.75mA / 120VAC
I/P: 120 VAC
O/P:NO LOAD
Ta:25℃
L- 0 FG:.62 mA
N-FG:0.62 mA P
PROTECTION FUNCTION TEST
NO
T EST ITEM
SPECICATION
TEST CONDITION
RESULT
VERDICT
1 OVER LOAD PROTECTION 105 %~ 135 % I/P: 115 VAC
O/P:TESTING
Ta:25℃
1 % 28
Hiccup mode, recovers
automatically after fault
condition is removed
P
2 OVER VOLTAGE PROTECTION CH1: 31.5V~ 37.5 V I/P: 115 VAC
O/P:10% LOAD
Ta:25℃
V 36.35
Hiccup mode, recovers
automatically after fault
condition is removed
P
3 SHORT PROTECTION SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
I/P: 115 VAC
O/P: FULL LOAD
Ta:25℃
NO DAMAGE
Hiccup mode, recovers
automatically afte
r fault
condition is removed
P
ENVIRONMENT TEST
NO
T EST ITEM
SPECICATION
TEST CONDITION
RESULT
VERDICT
1 TEMPERATURE RISE TEST MODEL SD:- D- 150 12
1. ROOM AMBIENT BURN- 8 IN:HRS
I/P: 24 VDC O/P: FULL LOAD Ta= 24 ℃
NO Position ROOM A MBIENT
Ta= 22.4
℃
1
Q6
82.8℃
2
T1
80℃
3
D11
77.2℃
4
C33
56.2℃
5
L1
83.3℃
6
C5
63.5℃
7
LF1
68.8
℃
8
BD
94.5℃
P
2 OVER LOAD BURN- IN TEST NO DAMAGE
1 HOUR ( MIN )
I/P: 96 VDC
O/P: 121οΉͺLOAD
Ta:25
℃
TEST
:
OK
P
3 LOW TEMPERATURE
TURN ON TEST
TURN ON AFTER 2 HOUR
I/P: 96 VDC
O/P: 100%LOAD / 80%LOAD
Ta= 0℃ ℃/-10
TEST:OK
P
150W Single Output DC DC Converter-
SD-150
series
Model: SD- D-150 24 Test Report 3 / 3
5 TEMPERATURE
COEFFICIENT
+ 0.03 %(0~25
℃
)
I/P: 96 VDC
O/P:FULL LOAD
+ 0.01%(0~25
℃
)
P
6 VIBRATION TEST 1 Carton & 1 Set Operating at I/P:96 VDC NO LOAD
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:10min/sweep cycle
(4) Acceleration:2G
(5) Test Time:1 hour in each axis (X.Y.Z)
(6) Ta:25℃
TEST:OK
P
SAFETY TEST
NO
T EST ITEM
SPECICATION
TEST CONDITION
RESULT
VERDICT
1 WITHSTAND P-VOLTAGE I/ O/P: 1.5 KVAC/min
I/P-FG: 2 KVAC/min
O/P-FG: 0.5 KVAC/min
I/P-O/P: 1.8 KVAC/min
I/P- FG: 2.4 KVAC/min
O/P-FG: 0.6 KVAC/min
Ta:25℃
I/P O/P: 4.5- mA
I/P FG: - 7.7 mA
O/P 3.8-FG: mA
NO DAMAGE
P
2 ISOLATION I/P RESISTANCE - O/P:500VDC>100MΞ©
I/P-FG: 500VDC>100MΞ©
O/P- FG:500VDC>100MΞ©
I/P-O/P: 500 VDC
I/P FG: - 500 VDC
O/P- FG: 500 VDC
Ta:25
℃
I/P-O/P: 2G Ξ©
I/P-FG: 2G Ξ©
O/P-FG: 2G Ξ©
NO DAMAGE
P
E.M.C TEST
NO
T EST ITEM
SPECICATION
TEST CONDITION
RESULT
VERDICT
1 RADIATION EN55032
CLASS B
I/P: 96 VDC
O/P:FULL LOAD
Ta:25℃
PASS
Test by certified Lab P
2 E.S.D -4-2 EN61000
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
I/P: 96 VDC
O/P:FULL LOAD
Ta:25℃
CRITERIA A
P
3 E.F.T -4-4 EN61000
LIGHT INDUSTRY
INPUT: 1KV
I/P: 96 VDC
O/P:FULL LOAD
Ta:25℃
CRITERIA A
P
4 Test by certified Lab Test Report PrepareοΌ†
M.T.B.F & LIFE CYCLE CALCULATION
NO
T EST ITEM
SPECICATION
TEST CONDITION
RESULT
VERDICT
1 CAPACITOR
LIFE CYCLE
SUPPOSE C33 IS THE MOST CRITICAL COMPONENT
I/P: 96VDC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 67181 HRS
I/P: 96VDC O/P:FULL LOAD Ta= 40 ℃ LIFE TIME= 30064 HRS
P
2 MTBF 2897.06K hrs min. Telcordia SR 332 (Bellcore) ; 419.6K hrs min. MIL- - - )HDBK 217F (25℃
P
SAMPLE
TEST RESULT
TESTER
APPROVAL
RD SMAPLE PASS H.C.LIOU MAX LIN


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: SD-150D-24
Gewicht: 850 g
Breedte: 110 mm
Diepte: 199 mm
Hoogte: 50 mm
Duurzaamheidscertificaten: RoHS
Aantal per verpakking: 16 stuk(s)
Ingangsspanning: 72 - 144 V
Uitgangsvermogen: 150 W
Spanning: 24 V