Installaon Manual
Type
DC-DC converter Families PSD, SD, RSD
Introducon
A DC-DC converter is a device used to convert a DC source from one voltage level to another. Mean Well’s DC-DC
converters equipped with internal EMI lter stage that possess the required EMC performance.
Installaon
( )1Before commencing any installaon or maintenance work, please disconnect your system from the
ulity. Ensure that it cannot be re-connected inadvertently!
( )2For PCB type, at least 5mm insulaon distance around the unit should be kept.
( )3Allow good venlaon for the unit in use to prevent it from overheang. Also, a 10-15 cm clearance
must be kept when the adjacent device is a heat source.
( )4Mounng orientaons other than standard orientation or operate under high ambient temperature
may increase the internal component temperature and will require a de-rang in output current.
Please refer to the specicaon sheets to receive opmum mounng posion and informaon the
about the -rang curve.de
( )5Recommended input/output wires are shown as below.
AWG
18
16
14
12
10
8
Rated Current of
Equipment (Amp)
6A
6-10A
10- 16A
16 25A-
25 32A-
32 40A-
Cross-secon of
Lead(mm2 )
0.75
1.00
1.5
2.5
4
6
Note: Current each wire carries should be de-rated to 80% of the current
suggested above when using 5 or more wires connected to the unit.
( )6For PCB type, compable mang housing please refers to the specicaons
( )7 For enclosed type, make sure that all strands of each stranded wire enter the terminal connecon and the
screw terminals are securely xed to prevent poor contact.
( )8 For other informaon about the products, please refer to www.meanwell.com for details.
Warning / Cauon !!
( )1Risk of electrical shock and energy hazard. All should be examined by a qualied technician. failure
Please do not try to x the converter by yourself!
( )2Risk of irreparable damage. Do not reverse polarity, both input and output.
( )3Please do not install converters in places with high moisture or near the water.
( )4Please do not install converters in places with high ambient temperature or near re source. Please
refer to the specicaons about the maximum ambient temperature limitaons.
( )5Output current and output waage must not exceed the rated values on specicaons.
( )6The ground (FG) must be connected to earth ground.
( )7For system consideraons, PCB and enclosed type converters may require an addional inrush
current liming circuit to suppress high inrush current surges. If you are uncertain about that circuit,
contact Mean Well.
( )8 All of an WellMe ’s converters are designed in accordance with EMC regulaons and the related test reports
are available by request. Since they are belong to component power supplies and will be installed inside
system enclosure, when they are integrated into a system, the EMC characteriscs of the end system must be
re-veried again.


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: RSD-60H-24
Gewicht: 240 g
Breedte: 60 mm
Diepte: 128 mm
Hoogte: 25 mm
Duurzaamheidscertificaten: RoHS
Aantal per verpakking: 48 stuk(s)
Ingangsspanning: 40 - 160 V
Uitgangsvermogen: 60 W
Spanning: 24 V

Heb je hulp nodig?