Mean Well NDR-75-24 Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor Mean Well NDR-75-24 (3 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 15 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
Installaī†½on Manual
ļ¬ Typeļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼šNDR DIN rail power supply Series NDR-75,
ļ¼ˆ
ļ¼ˆ
ļ¼ˆ
ļ¼ˆļ¼ˆ ļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼š 120, 240, 480ļ¼‰
ļ¼‰
ļ¼‰
ļ¼‰ļ¼‰
N - - INPUT: -240VAC 1.6A 50/60Hz OUTPUT: V 6.3A DR 75 12 100 12
N - - INPUT: -240VAC 1.6A 50/60Hz OUTPUT: V 3.2A DR 75 24 100 24
N - - INPUT: -240VAC 1.6A 50/60Hz OUTPUT: V 1.6A DR 75 48 100 24
N -120- INPUT: -240VAC 2.6A 50/60Hz OUTPUT: V A DR 12 100 12 10
N -120- INPUT: -240VAC 2.6A 50/60Hz OUTPUT: V 5A DR 24 100 24
N -120- INPUT: -240VAC 2.6A 50/60Hz OUTPUT: V 2.5A DR 48 100 48
NDR-240- INPUT: -240VAC 2.8A 50/60Hz OUTPUT: V A 24 100 24 10
NDR-240- INPUT: -240VAC 2.8A 50/60Hz OUTPUT: V 5A 48 100 48
NDR-480- INPUT: -240VAC 5.3A 50/60Hz OUTPUT: V A 24 100 24 20
NDR-480- INPUT: -240VAC 5.3A 50/60Hz OUTPUT: V A 48 100 48 10
ļ¬ Introducī†½on
NDR is a DIN rail power supply series with an economical price and slim design. Like other Mean Well DIN series, ā€™s
they can be mounted on a TS35 Standard DIN rail.
ļ¬ Installaī†½on
ļ¼ˆ ļ¼‰1 Always allow good venī†¼laī†¼on clearances, 5mm leī…· and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheaī†¼ng. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
ļ¼ˆ ļ¼‰2 The appropriate mounī†¼ng orientaī†¼on for the unit is verī†¼cal, the input terminals the bottom and output on at
the top. Mounī†¼ng orientaī†¼ons other than that, such as upside down, horizontal, or table-top mounī†¼ng, is not
allowed.
ļ¼ˆ ļ¼‰3 Use copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
Rated Current of
Equipment (Amp)
7A
10A
15A
20A
Cross-secī†¼on of
Lead(mm2 )
0.8
1.3
2.1
3.3
Note: Current each wire carries should be de-rated to 80% of the current suggested
above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connecī†¼on and the screw terminals are
securely ī…™xed to prevent poor contact. If the power supply possesses mulī†¼-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
ļ¼ˆ ļ¼‰4 Use wires that can withstand temperatures of at least 80Ā°C, such as UL1007.
ļ¼ˆ ļ¼‰5 Recommended wire strapping length m (0.197 . is 5m ā€)
ļ¼ˆ ļ¼‰6 Recommended screwdriver is 3 , sloī‡†ed type.mm
Installaī†½on Manual
3
1
2
ļ¼ˆ ļ¼‰7 The recommended torque seī‡¢ng for terminals is shown as below.
I/P
O/P
6.9 kgf- (6 -in) cm Lb
6.9 kgf- (6 Lb-in) cm
10.35 kgf- (9 Lb-in) cm
10.35 kgf- cm (9 Lb-in)
10.35 kgf- (9 Lb-in) cm
10.35 kgf- (9 Lb-in) cm
10.35 kgf- (9 Lb-in) cm
10.35 kgf- (9 Lb-in) cm
ļ¼ˆ ļ¼‰8 Suggested fuse and maximum number of the SDR PSUs that can be connected to a circuit breaker at 230V are
shown as below.
Model
Fuse
Circuit breaker
C16
D 16
N - DR 75
T3.15A/L250V
6
13
N -120 DR
T4A/L250V
5
10
NDR-240
T5A/L250V
4
10
NDR-480
T8A/L250V
3
5
ļ¼ˆ ļ¼‰9 Mounī‡–ng Instrucī‡–onļ¼š
Mount as shown in ī…³gure only, with input terminals down, or else suī…½cient cooling will not be possible.
Admissible DIN railļ¼šTS35/7.5 or TS35/15
For rail fastening ļ¼š
ļ¼ˆ ļ¼‰a Tilt the unit slightly rearwards.
ļ¼ˆ ļ¼‰b Fit the unit over top hat rail.
ļ¼ˆ ļ¼‰c Slide it downward unī‡–l it hits the stop.
ļ¼ˆ ļ¼‰d Press against the bottom for locking.
ļ¼ˆ ļ¼‰e Shake the unit slightly to check the locking acī‡–on.
ļ¼ˆ ļ¼‰11 For other informaī‡–on about the products, please refer to www.meanwell.com for details.
ļ¬ Warning / Cauī†½on !!
ļ¼ˆ ļ¼‰1Risk of electrical shock and energy hazard. All failure should be examined by a qualiī…³ed technician. Please do
not remove the case of the power supply by yourself!
ļ¼ˆ ļ¼‰2Risk of electric arcs and electric shock (danger to life). Connecī‡–ng both t primary and the secondary sides he
together is not allowed.
ļ¼ˆ ļ¼‰3Risk of burn hazard. Do not touch the unit in operaī‡–on and shortly aī†‘er disconnecī‡–on!
ļ¼ˆ ļ¼‰4 Risk of ī…³re and short circuit. The openings should be protected from foreign objects or dripping liquids.
ļ¼ˆ ļ¼‰5 Only install the unit in a polluī‡–on degree 2 environment (Note.1).
ļ¼ˆ ļ¼‰6 Please do not install the unit in places with high moisture or near the water.
"Click"
Installaī‡on Manual
ļ¼ˆ ļ¼‰7The maximum operaī†½ng temperature is for NDR/EDR- - ; 50 for NDR/EDR- -24/48, 45Ā°C 75 12 Ā°C 75
NDR/EDR-120-12/24/48, NDR-240-24/48, NDR-480-24/48, please do not install the unit in places with high
ambient temperature or near ī…™re source.
ļ¼ˆ ļ¼‰8 The FG ( ) must be connected to (Protective Earth). PE
ļ¼ˆ ļ¼‰9 Output current and output waī‡‡age must not exceed the rated value on its speciī…™caī†½on.
ļ¼ˆ ļ¼‰10 Disconnect system from supply voltage:
Before commencing any installaī†½on, maintenance or modiī…™caī†½on work: Disconnect your system from
supply voltage. Make sure that inadvertent connecī†½on in circuit will be impossible!
ļ¼ˆ ļ¼‰11 For conī†½nued protecī†½on against risk of ī…™re, replace only with same type and raī†½ng of fuse.
Pour ne pas compromeī†Ære la protecī†„on contre les risquĆ© dā€™incendie, remplacer par un fusible de mĆŖme
type et de memes caractĆ©risī†½ques nominales.
Note.1: Polluī†½on Degree 2 applies where there is only non-conducī†½ve polluī†½on that might temporarily become
conducī†½ve due to occasional condensaī†½on. Generally refer to dry, well-venī†½lated locaī†½ons, such as
control cabinets.
Manufacturerļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼š
MEAN WELL ENTERPRISES Co., L .TD
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Oī…¢ceļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼š
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510- -8886 683
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: + - - -6000 31 20 758
Web: www.meanwell.eu


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: NDR-75-24
Kleur van het product: Blue, Metallic
Gewicht: 510 g
Breedte: 32 mm
Diepte: 102 mm
Hoogte: 125.2 mm
Geluidsniveau: - dB
Temperatuur bij opslag: -40 - 85 Ā°C
Stroomspanning bescherming: Over voltage, Overheating, Overload
Luchtvochtigheid bij opslag: 10 - 95 procent
Mean time between failures (MTBF): 486200 uur
Totaal vermogen: 76.8 W
Efficientie: 85.5 procent
AC-ingangsspanning: 90 - 264 V
AC-ingangsfrequentie: 47 - 63 Hz
Bedrijfstemperatuur (T-T): -20 - 70 Ā°C
Relatieve vochtigheid in bedrijf (V-V): 20 - 95 procent
Ventilator diameter: - mm
Houd-tijd: 12 ms
Voltage tolerantie: 1 procent
Toename-tijd: 2000 ms

Heb je hulp nodig?

Als je hulp nodig hebt met Mean Well NDR-75-24 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Mean Well

Handleiding Niet gecategoriseerd