Mean Well LCM-60 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Mean Well LCM-60 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Features
Wiring
Environmental limitations
Cautions
Settings and connections
1. Output Current Level Settings
‧
‧
‧
‧
‧
‧
‧
180~295VAC input only
Built-in active PFC
Output curr ent lev el selectable by DIP switch
Built-in DALI interface and pus h dimming function (DA version)
Buil t-in 0~10Vdc and PWM sig nal dimmi ng function (Non -DA version)
Power supp ly syn chroni zation function up to 1 0 un its
Temperature compensation function by external NTC
‧
‧
‧
‧
‧
‧
‧
Clas s po wer un it, ung rounded
Buil t-in 12V/50mA auxiliary ou tput
Full plastic case enclos ed
No l oad power consumption <1W (1.2W for DA ve rsion)
Protection s: Short circuit / Over voltage / Over temperature
3 year war ranty
Suit able fo r intell igent LED lighting
β…‘
‧
‧
‧
‧
Hous ing with cabl e clamp for re mote installation
Use wires with an adequate cross-section (see 5)
Use suitable mounting tools to do the wiring and mounting (see 5)
MCB circuit breaker) with an adequate current rating to protect the lighting system (see 6)Use a (miniature
‧
‧
‧
Maxi mum ambient temperature must not exceed 60
Always allow adequate ventilation clearances, 50mm, aro und the unit in use to prevent it from overheating
Only install the unit in interior environments
℃
‧
‧
This unit must be installe d by a qualified electrician
This unit is not suitable for applications that DC/DC converters are connected befor e LED lamps
The LCM can prov ide various output currents by se tting the DIP switch. The settings of the DIP switch are shown in the tables below.
LCM-40(DA ) LCM-60(DA)
Note : 1.Fac tory default setting is 70 0mA.
2.Out put vo ltage a nd o utput wa ttage mus t n ot exc eed th e ra te d val ues.
Voltage
ran ge
Voltage
ran ge
1 12 23 34 45 56 6
Sel ectable
Current
Sel ectable
Current
2-100V 2-90V- -- ------ ---- -- - ----- ---- -- - ----- ---
--- ---- -- - ----- ---- -- - ----- ---
- -- - ----- ---
--- ---
- -- - --
- -- - --
- -- - --
--- ---
ON ON
ON ONON ON
ON ONON ONON ONON ON
ON ONON ONON ONON ONON ON
ON ONON ONON ONON ONON ONON ON
350mA 50 0mA
2-8 0V 2-9 0V50 0mA 60 0mA
2-6 7V 2-8 6V60 0mA 70 0m A*
2-5 7V 2-6 7V70 0m A* 90 0mA
2-4 5V 2-5 7V90 0mA 10 50mA
2-4 0V 2-4 2V10 50mA 14 00mA
LCM-40(DA), LCM-60(DA) installation manual
ON
6 5 4 3 2 1
-Vo
+Vo
SYN.
+
-NT C
+DI M
-DIM
+NT C
-FAN
+FAN
+
DA-
DA+
PUSH
AC /N
AC /L
Terminal blocks assignment for LCM
2. Connection of LED Lamps
Press down the "push button" by a slotted screw driver to insert or remove the cable.
Vo-
Vo+
AC/N
AC/L
NEU TRAL (Blue o r whit e)
LIVE (Brow n or black )
http: //www.meanwell.c om
ο“ο…οŒο–
  
ο€±ο€±ο€°
123.5mm 23mm
3. Connection of Dimming Functions
4. NTC Connection
5. Recommended Scre wdriver, Wire and Torque Setting
6. Suggested Maximum Number of the LCM Units that can be Connected to a MCB (miniature circuit breaker ) at 230Vac
a. 0-10Vdc or 10V PWM (non-DA version only)
c. Push dim (DA version only)
d. Synchronization ope ration
The lights LCM units (slaves) can be dimmed synchronously through a LCM unit (the master) directly controlled viadriven by
0-10Vdc, 10V PWM, DALI or push dim dimming function. The wiring is show n as below.
No te: ON LY use open push button witho ut indi cator l ight.
Warning: Risk of short circuit. The push button can on ly be linked between the PUSH and the AC/L (brown or black).
DO NOT connect the push button to the AC/N (blue or white).
b. DALI (DA version only)
Note : Maximum DALI cable length is 300m
(based on a 1.5mm or 14AWG cable)
2
DA+
DA- DALI
co ntro l ler
Dimming control mechanism
Function
Turn ON/OFF
Dim UP/DOWN
Reset
None
Pushing time
0.1 ~ 1 sec
1.5 ~ 10 sec
> 11 sec
< 0.05 sec
SYN.
+-
+
-
SYN.
+-
+
-
SYN.
+-
+
-
Master Slave 1 Slave 2
‧
‧
‧
Mating housing for SYN. connectors : JST B2B-XH or equivalent
Maximum number of the LCM units : 10 (1 master + 9 slaves)
Maximum cable length between each units : 20m (based on a cable with cross-section of 0.15mm ~0.3mm or AWG No. of 22 ~ 26)
2 2
Note 1 : DO NOT connect dimming circuitry to slaves.
Note 2 : Pl ease make sure all units are set to 100% dimming setting (factory default) before synchronizing.
Note: These calculated v alues are based on MCB S201 series manu factured by A BB.
http: //www.meanwell.co m
Type
Model B10 B16 C10 C16
LCM-40(DA) 10 16 17 28
LCM-60(DA) 9 15 16 26
Solid wire
Stranded wire
American w ire gauge
Wire stripping length
Screwdriver
Recommended tig htening tor que
Suggested push-down strength
-----
-----
-----
-----
6mm Phillips
4.6 kgf-cm (4 lb-in)
-----
The cover
(the blue one)
Push terminal
(ACL/N, PUSH, DA , Vo )Β± Β±
ψ ψ1.024 - 1.628mm
0.823 - 2.08mm2
14 - 18AWG
10mm (0.39")
3mm Phillip s
-----
3 - 4 kp (6.61-8.81 lb )
F
‧
‧
It will always dim up when light intensity is lower than 10%, whe reas it will
Factory dimming setting: 100%
always dim down when light intensity is higher than 90%
DIM-
DIM+ 0~ 10V DC
+
-
NTC-
NTC+
AC/L
AC/N
Push Butto nPUSH
LIVE (Brown or black)
NEUTRAL (Bl ue or white)
ψ ψ0.404 - 0.643 mm
0.12 9 - 0.3 26mm2
22 - 26AWG
7mm (0.27 ")
3mm Philli ps
2.88 kgf-cm (2.5 lb-in)
-----
Scr ew ter minal
(FAN , NT C , DIM )Β± Β± Β±


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: LCM-60
Gewicht: 240 g
Breedte: 123.5 mm
Diepte: 81.5 mm
Hoogte: 23 mm
Stroom: 0.32/230VC, 0.27/277VC A
Uitgangsvermogen: 60.3 W
Oververhittingsbeveiliging: Ja
Frequentie: 47 - 63 Hz
Spanning: 102 V
Power factor: 0.97
AC-ingangsspanning: 180 - 295 V
Bedrijfstemperatuur (T-T): -30 - 90 Β°C
Short circuit bescherming: Ja