Mean Well EDR-120-24 Handleiding


Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor Mean Well EDR-120-24 (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
Test Report: EDR-120-24
1 20W Single Output Industrial DIN RAIL
๏ฎ DESIGN VERIFY TEST
O F Tutput unction est
Input Function Test
Protection Function Test
C omponent Stress Test
๏ฎ SAFETY & . E.M.C TEST
Safety Test
E.M.C. Test
๏ฎ RELIABILITY TEST
ENVIRONMENT TEST
120W Single Output Industrial DIN RAIL
EDR- 120 series
Model: EDR- -120 24 Test Report 2 / 6
๏ฎ DESIGN VERIFY TEST
MODEL๏ผš
๏ผš
๏ผš
๏ผš๏ผšE -1 - DR 20 24
DVT TEST
OUTPUT FUNCTION TEST
NO
T EST ITEM
SPECIFICATION
RESULT
VERDICT
1 RIPPLE & NOISE V1: p-120 mV p (Max )
I/P:230VAC
O/P:FULL LOAD
Ta:25โ„ƒ
V1: -33.8 mVp p (Max )
P
2
OUTPUT VOLTAGE
ADJUST RANGE
CH1: V 24 V~ 28
I/P: 230VAC/115VAC
O/P:MIN LOAD
Ta:25โ„ƒ
23.23V~ V/28.71 230VAC
23.23V~ V/28.71 115VAC P
3 OUTPUT VOLTAGE
TOLERANCE
V1: 1 %~ -1 % (Max) I/P: 100VAC /264VAC
O/P:FULL/ MIN. LOAD
โ„ƒ
V1:0.074 %~-0.074%
P
4 LINE REGULATION V1:0.5 %~ - % ~ 0.5 (Max) I/P: 100VAC 264VAC
O/P:FULL LOAD
Ta:25โ„ƒ
V1: 0.025%~ -0%
P
5 LOAD REGULATION V1: 1 %~ -1 % (Max) I/P: 230VAC
O/P:FULL ~MIN LOAD
โ„ƒ
V1:0.074 %~-0.074%
P
6 SET UP TIME
230VAC/12 00ms (Max)
115VAC/2500ms (Max)
I/P: 230VAC/115VAC
O/P:FULL LOAD
Ta:25โ„ƒ
230VAC/731.218ms
115VAC/1584.837ms P
7 RISE TIME 230VAC/60ms (Max)
115VAC/60ms (Max)
I/P: 230VAC/115VAC
O/P:FULL LOAD
โ„ƒ
230VAC/ 26.506ms
115VAC/27.797ms P
8 HOLD UP TIME 230VAC/16ms (TYP)
115VAC/ TYP1 (0ms )
I/P: 230VAC/115VAC
O/P:FULL LOAD
Ta:25โ„ƒ
230VAC/59.079ms
115VAC/ 12.462ms P
9 OVER/UNDERSHOOT TEST + < 5% I/P: 230VAC
O/P:FULL LOAD
โ„ƒ
<5%
P
10
DYNAMIC LOAD -p V1: 2400 mVp I/P: 230VAC
O/P(1)FULL /Min LOAD
90%DUTY/1KHZ
(2) (1)FULL /Min LOAD
90%DUTY/3 KHZ
(3)FULL /Min LOAD
90%DUTY/5 KHZ
(4)FULL /Min LOAD
50%DUTY/120HZ
Ta:25โ„ƒ
2 -p 81mVp
-p 303 mVp
2 -p 91mVp
3 m -p 11 Vp
P
INPUT FUNCTION TEST
120W Single Output Industrial DIN RAIL
EDR- 120 series
Model: EDR- -120 24 Test Report 3 / 6
NO
T EST ITEM
SPECIFICATION
TEST CONDITION
RESULT
VERDICT
1 INPUT VOLTAGE RANGE 90VAC~264 VAC
127VDC ~ 370VDC
I/P:TESTING
O/P:FULL LOAD
Ta:25โ„ƒ
(1)65.706 V V~264
(2)113.69Vdc~370Vdc/FULL LOAD
11 3.68Vdc~370Vdc/50% LOAD
(3) 113.68Vdc~370Vdc/FULL LOAD
113.68Vdc~370Vdc/50% LOAD
P
I/P:
(1)LOW- - 8 LINE 3V= 7 V
- V HIGH LINE+15%=300
O/P:FULL/MIN LOAD
ON: 30 Sec OFF: 30 Sec 10MIN
(2)230Vac
ON: 0.5 0.5 Sec OFF: Sec 20MIN
(3)230Vac
ON:3Sec OFF:3Sec 12HOURS
( POWER ON/OFF NO DAMAGE )
TEST:OK
2 INPUT FREQUENCY RANGE 47HZ ~63 HZ
NO DAMAGE
I/P:100 VAC ~264 VAC
O/P:FULL~MIN LOAD
Ta:25
โ„ƒ
TEST: OK
P
4 EFFICIENCY 8 % 7.5 (TYP) I/P:230 VAC
O/P:FULL LOAD
Ta:25
โ„ƒ
8 % 9.07
P
5 INPUT CURRENT 230V/ 1.3A (Typ)
115V/ 2.25 A (Typ)
I/P: 230 VAC/115VAC
O/P:FULL LOAD
Ta:25
โ„ƒ
I =0.99A/ 230VAC
I =2.07A/ 115VAC
P
6 INRUSH CURRENT 230V/35A (Typ)
115V/20A (Typ)
COLD START
I/P:230VAC/115VAC
O/P:FULL LOAD
Ta:25
โ„ƒ
I =32.437A/ 230VAC
I =17 .750A/ 115VAC
P
PROTECTION FUNCTION TEST
NO
T EST ITEM
SPECIFICATION
TEST CONDITION
RESULT
VERDICT
1
OVER LOAD PROTECTION 105%~130%
RATED OUTPUT POWER
I/P: 264VAC
I/P: 230VAC
I/P: 100VAC
O/P:TESTING
Ta:25โ„ƒ
113.8%/ 264VAC
113.5 / % 230VAC
114.0%/100VAC
Protection type : Constant current
limiting, recovers automatically after
fault condition is removed
P
2
OVER VOLTAGE PROTECTION CH:29V~33V(Typ)
I I/P:264VAC
I/P: 230VAC
I/P: 90VAC
O/P:MIN LOAD
Ta:25โ„ƒ
30.75V/ 264VAC
30.71V / 230VAC
30.68V/90VAC
Protection type : Shut down o/p
voltage, re-power on to recover
P
3 OVER TEMPERATURE PROTECTION NO DAMAGE I/P: 230 VAC
O/P:FULL LOAD
O.T.P. Active
Shut down o/p voltage, re-power on
to recover P
4 SHORT PROTECTION SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
I/P: 264VAC
O/P: FULL LOAD
Ta:25โ„ƒ
NO DAMAGE
Constant Current Limiting
P
COMPONENT STRESS TEST
NO
T EST ITEM
SPECIFICATION
TEST CONDITION
RESULT
VERDICT


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: EDR-120-24
Gewicht: 550 g
Breedte: 40 mm
Diepte: 113.5 mm
Hoogte: 125.2 mm
Duurzaamheidscertificaten: RoHS
Aantal per verpakking: 20 stuk(s)
Ingangsspanning: 90 - 264 V
Uitgangsvermogen: 120 W
Output current: 5 A
Spanning: 24 V

Heb je hulp nodig?

Als je hulp nodig hebt met Mean Well EDR-120-24 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Mean Well

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd