Mean Well APV-12-12 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Mean Well APV-12-12 (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 23 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
12W Single Output Switching Power Supply APV-12 series
Model: APV-12-12 Test Report 1 / 6
MODEL:
:
:
::APV-12-12
OUTPUT FUNCTION TEST
NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
1 RIPPLE & NOISE V1: 120 mVp-p (Max ) I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
V1: 16 mVp-p (Max )
PASS
2 OUTPUT VOLTAGE
TOLERANCE
V1: -5 %~ +5 % (Max)
I/P: 100VAC / 264 VAC
O/P:FULL/ 0% LOAD
Ta:25℃
V1: -0.933%~ 1.133 %
PASS
3 LINE REGULATION V1: -1 %~ +1 % (Max)
I/P: 100 VAC ~ 264VAC
O/P:FULL LOAD
Ta:25℃
V1: -0.008 %~ 0.025 %
PASS
4 LOAD REGULATION V1: -2 %~ +2 % (Max)
I/P: 230 VAC
O/P:FULL ~MIN LOAD
Ta:25℃
V1: -0.09 %~ 0.09 %
PASS
5 SET UP TIME
230VAC/ 1500 ms (Max)
115VAC/ 1500 ms (Max)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230 VAC/ 439.98 ms
115 VAC/ 889.77 ms
PASS
6 RISE TIME 230VAC/ 30 ms (Max)
115VAC/ 30 ms (Max)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230 VAC/ 19.24 ms
115 VAC/ 21.18 ms
PASS
7 HOLD TIME 230VAC/ 20 ms (Typ)
115VAC/ 15 ms (Typ)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230 VAC/ 82.47 ms
115 VAC/ 17.24 ms
PASS
8 OVER/UNDERSHOOT TEST < Β±5 % I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
TEST: Β±1.317%
PASS
9 DYNAMIC LOAD V1: 1200 mVp-p I/P: 230 VAC
O/P: (1)FULL /Min LOAD
90%DUTY/1KHZ
(2)FULL /Min LOAD
50%DUTY/120HZ
Ta:25℃
(1) 170 mVp-p
(2) 530 mVp-p
PASS
12W Single Output Switching Power Supply
APV-12 series
Model: APV-12-12 Test Report 2 / 6
INPUT FUNCTION TEST
NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
1 INPUT VOLTAGE RANGE 90 VAC~ 264 VAC I/P:TESTING
O/P:FULL LOAD
Ta:25℃
90 V~ 264 V
PASS
(1)I/P: LOW-LINE-3V= 87 V
HIGH-LINE+15%= 300 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
(2) I/P:230VAC
ON: 0.5 Sec . OFF: 0.5 Sec 20MIN
( AC POWER ON/OFF NO DAMAGE )
TEST:
(1) OK
(2) OK
2 INPUT FREQUENCY RANGE 47HZ ~63 HZ
NO DAMAGE OSC
I/P: 90 VAC ~264 VAC
O/P:FULL~MIN LOAD
Ta:25℃
TEST: OK
PASS
3 EFFICIENCY 82 % (Typ) I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
84.17 %
PASS
4 INPUT CURRENT 230 V/ 0.2 A (Typ)
115 V/ 0.35 A (Typ)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
I =0.162A/ 230VAC
I =0.238A/ 115VAC
PASS
5 INRUSH CURRENT 230 V/ 70 A
115 V/ 35 A
COLD START
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
I =57.69 A/ 230VAC
I =26.20 A/ 115VAC
PASS
PROTECTION FUNCTION TEST
NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
1
OVER LOAD PROTECTION Above 105%
RATED OUTPUT POWER
I/P: 264 VAC
I/P: 230 VAC
I/P: 100 VAC
O/P:TESTING
Ta:25℃
143 %/264VAC
140 %/ 230VAC
121 %/ 100 VAC
Hiccup Mode
PASS
2
OVER VOLTAGE PROTECTION CH1: 13.8 V~ 16 V I/P: 264 VAC
I/P: 230 VAC
I/P: 90 VAC
O/P:MIN LOAD
Ta:25℃
14.72 V/264VAC
14.78 V/ 230VAC
14.64 V/ 90VAC
Shut off O/P voltage, clamping by
zener diode
PASS
3 SHORT PROTECTION SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
I/P: 264 VAC
O/P: FULL LOAD
Ta:25℃
NO DAMAGE
Hiccup Mode
PASS
12W Single Output Switching Power Supply
APV-12 series
Model: APV-12-12 Test Report 3 / 6
ENVIRONMENT TEST
NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
1
TEMPERATURE RISE TEST MODEL: APV-12-24
1. ROOM AMBIENT BURN-IN: 2 HRS
I/P: 230 VAC O/P: 100% LOAD Ta= 21.7 ℃
2. HIGH AMBIENT BURN-IN: 2 HRS
I/P: 230 VAC O/P: 100% LOAD Ta= 43.4 ℃
NO Position P/N ROOM AMBIENT
Ta= 21.7 ℃
HIGH AMBIENT
Ta= 43.4 ℃
1 BD1 KBP208G 43.0 65.2℃ ℃
2 L1 DRGZ001D 44.2 66.8℃ ℃
3 D1 1N4007 58.5 81.6℃ ℃
4 R5 1/2W 150KΩ 62.2 84.1℃ ℃
5 U1 SD4843 57.8 83.3℃ ℃
6 T1 TF6328 65.4 86.6℃ ℃
7 D10 SR3100 64.8 85.0℃ ℃
8 D2 FR104 52.9 75.9℃ ℃
9 C5 12uF/400V 105℃ KM 40.3 62.4℃ ℃
10 C6 12uF/400V 105℃ KM 52.2 74.8℃ ℃
11 C9 22uF/50V L5Kh KY 48.6 72.0℃ ℃
12 C15 220uF/25V UL7Kh KY 53.4 73.9℃ ℃
13 C17 220uF/25V LL3K GL 51.3 71.7℃ ℃
PASS
2 OVER LOAD BURN-IN TEST NO DAMAGE
1 HOUR ( MIN )
I/P: 230 VAC
O/P: 139% LOAD
Ta:25℃
TEST: OK
PASS
3 LOW TEMPERATURE
TURN ON TEST
TURN ON AFTER 2 HOUR
I/P: 264 VAC/100 VAC
O/P: 100% LOAD
Ta= -30 ℃
TEST: OK
PASS
4 HIGH HUMIDITY
HIGH TEMPERATURE
HIGH VOLTAGE
TURN ON TEST
AFTER 12 HOURS
IN CHAMBER ON
CONTROL 45 ℃
NO DAMAGE
I/P: 272 VAC
O/P:FULL LOAD
Ta= 45 ℃
HUMIDITY= 95 %R.H
TEST: OK
PASS
5 TEMPERATURE
COEFFICIENT
Β± 0.03 %(0~50℃) I/P: 230 VAC
O/P:FULL LOAD
Β± ℃ 0.003 %(0~50 )
PASS
6 STORAGE TEMPERATURE TEST
1. Thermal shock Temperature: -45℃~ +85℃
2. Temperature change rate :25℃ / MIN
3. Dwell time low and high temperature : 30 MIN/EACH
4. Total test cycle:5 CYCLE
5. Input/Output condition: STATIC
TEST: OK
PASS
7. THERMAL SHOCK TEST 1. Thermal shock Temperature: - 35 ℃~ + 50 ℃
2. Temperature change rate :25℃ / MIN
3. Dwell time low and high temperature : 30 MIN/EACH
4. Total test cycle:10 CYCLE
5. Input/Output condition: 230VAC/Full Load 58SEC ON/2SEC OFF
TEST: OK
PASS
8 VIBRATION TEST 1 Carton & 1 Set
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:10min/sweep cycle
(4) Acceleration:2G
(5) Test Time:1 hour in each axis (X.Y.Z)
(6) Ta:25℃
TEST: OK
PASS


Product specificaties

Merk: Mean Well
Categorie: Niet gecategoriseerd
Model: APV-12-12
Kleur van het product: Wit
Breedte: 77 mm
Diepte: 40 mm
Hoogte: 29 mm
Geluidsniveau: - dB
Temperatuur bij opslag: -40 - 80 Β°C
Stroomspanning bescherming: Over voltage, Overload
Luchtvochtigheid bij opslag: 10 - 95 procent
Mean time between failures (MTBF): 1145.7 uur
Totaal vermogen: 12 W
Efficientie: 82 procent
AC-ingangsspanning: 90 - 264 V
AC-ingangsfrequentie: 47 - 63 Hz
Bedrijfstemperatuur (T-T): -30 - 70 Β°C
Relatieve vochtigheid in bedrijf (V-V): 20 - 90 procent
Ventilator diameter: - mm
Houd-tijd: 20 ms
Voltage tolerantie: 5 procent
Toename-tijd: 30 ms

Heb je hulp nodig?

Als je hulp nodig hebt met Mean Well APV-12-12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Mean Well

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd