Maxicool CTL50H4A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Maxicool CTL50H4A (16 pagina's) in de categorie Airconditioner - Aircooler. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Please read this installation manual carefully before installing your air conditioner.
Please keep this manual in a safe place for future reference.
This manual is suitable for cooling&heating .
FOUR-WAY CASSETTE TYPE
INSTALLATION MANUAL
50/V1.1
TROUBLES AND CAUSES
CAUTION
!
These are not failures
Room air is smelly.
A bad odor comes from the air conditioner.
Smells impregnated in the wall,carpet,furniture,clothing,or furs,are coming out. A white mist
of chilled air or water is generated from the outdoor unit.
If any of the following conditions occur,stop the air conditioner immediately,set off the power
switch, and contact the dealer.
The indicator lamps flash rapidly(five times per second),you disconnect the unit with the
power and then connect the unit with the power again after two or three minutes but the
lamps still flash.
Switch operations are erratic.
The fuse is blown frequently or the circuit breaker is tripped frequently.
Foreign matter or water has fallen inside the air conditioner.
Any other unusual condition is observed.
Before you ask for service or repairs,check the following points.
(CONCERNING REMOTE
CONTROLLER)
Setting Change is impossible
Symptoms Causes Reason and Disposal
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
AUTO
Check whether the MODE
indicated on the display is
DRY
When the automatic mode is
selected ,the air conditioner
automatically selects the fan
speed
When dry operation is selected,
the air conditioner automatically
select the fan speed .The fan speed
can be selected during COOL
and FAN ONLY,and HEAT mode.
The Transmission lndicator Never Comes On
Symptoms Causes Reason and Disposal
The remote control signal is
not transmitted even when
the ON/OFF button is pushed.
Check whether the batteries
in the remote controller are
exhausted.
The remote control signal is
not transmitted,because the
power supply is off.
The Display never comes on
Symptoms Causes Reason
The TEMP.indicator does not
come on.
Check whether the MODE
indicated on the display is
FAN ONLY
The temperature cannot be
set during fan only operation.
Please narrate the manual to the customers in detail.
INSTALL MANUAL of indoor and outdoor unit must be handed over to the customers.
HAND OVER TO CUSTOMERS
29
4
1
10
13
CONTENTS
IMPORTANT SAFETY INFORMATION
TROUBLES AND CAUSES
ADJUSTING AIR FLOW DIRECTION
DISPLAY PANEL
CHARGE ADDITOINAL refrigerant
AIR PURGING
ELECTRIC WIRING
TEST RUN
REFRIGERANT PIPE INSTALLATION
OUTDOOR UNIT INSTALLATION
INSTALLATION OF PANEL
DRAINAGE PIPE INSTALLATION
PRECAUTION
REMOTE CONTROTROLLER OPERATIONS
INDOOR UNIT INSTALLATION
MAINTENANCE
FUNCTION AND OPERATION OF PANEL'S PARTS 3
5
16
18
19
20
21
22
25
26
26
28
29
Read the following " PRECAUTIONS" carefully before installation.
The caution items stated here must be followed because these important contents are related
to safety. The meaning of each indication used is as below.
Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
! This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to
properties only.
WARNING
! CAUTION
1. Injury means causing harmed, burned, electrical shocked, but not serious for hospitalization.
2. Damage of property means disrepair of property, material.
Carry out test running to confirm that no abnormality occurs after the installation. Then, expl-
ain to user the operation, care and maintenance as stated in instructions. Please remind the
customer to keep the operating instructions for future reference.
Engage dealer or specialist for installation. If installation done by user is defective, it
will cause water leakage, electrical shock or fire.
Install according to this installation instructions strictly. If installation is defective, it will
cause water leakage, electrical shock or fire.
Use the attached accessories parts and specified parts for installation. Otherwise, it will
cause the set to fall, water leakage, fire or electrical shock.
Install at a strong and firm location which is able to withstand the set's weight. If the stren-
gth is not enough or installation is not properly done, the set will drop and cause injury.
For electrical work, follow the local national wiring standard, regulation and this installa-
tion instructions. An independent circuit and single outlet must be used. If electrical circuit
capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
When carrying out piping connection, take care not to let air or other substances other
than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower
capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
Grounding is necessary. It may cause electrical shock if grounding is not perfect.
Do not install the unit at place where leakage of flammable gas may occur. In case gas
leaks and accumulates at surrounding of the unit, it may cause fire.
!WARNING
NOTE :
1
PRECAUTION
IMPORTANT SAFETY INFORMATION
CAUTION
!
Do not attempt to install this unit by yourself.This unit requires
installation by qualified persons.
DANGER
!
Do not attempt to service the unit yourself.This unit has no user
serviceable components.Opening or removing the cover will
expose you to dangerous voltage.Turn off the power supply will
not prevent potential electric shock.
DANGER
!
Never put hands or objects into the Air Outlet of indoor or outdoor
units.These units are installed with a fan running at high speed.
To touch the moving fan will cause serious injury.
DANGER
!
To avoid the risk of serious electrical shock,never sprinkle or
spill water or liquid on unit.
WARNING
!
Ventilate the room regularly while the air conditioner is in use,
especially if there is also a gas appliance in use in this room.
Failure to follow these directions may result in a loss of oxygen
in the room.
WARNING
!
To prevent electric shock,turn off the power or disconnect the
power supply plug before beginning any cleaning or other routine
maintenance.
WARNING
!
Do not use liquid cleaners or aerosol cleaners,use a soft and dry
cloth for cleaning the unit .To avoid electric shock,never attempt
to clean the units by sprinkling water.
CAUTION
!
Do not use caustic household drain cleaners in the unit.Drain
cleaners can quickly destroy the unit components(drain pan and
heat exchanger coil etc).
NOTE
!
For proper performance,operate the unit in temperature and
humidity ranges indicated in this owner s manual.lf the unit is
operated beyond these conditions,it may cause malfunctions
of the unit or dew dripping from the unit.
28


Product specificaties

Merk: Maxicool
Categorie: Airconditioner - Aircooler
Model: CTL50H4A

Heb je hulp nodig?

Als je hulp nodig hebt met Maxicool CTL50H4A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airconditioner - Aircooler Maxicool

Handleiding Airconditioner - Aircooler

Nieuwste handleidingen voor Airconditioner - Aircooler