Installation
Installation Installatie
Installation IVET
ENGLISH: Connect the AC load to the AC output (OUTPUT). For safe installation it is necessary to:
• Connect both the earth (PE/GND) and the neutral (N) of the AC output of the IVET to the central grounding point
which is connected to the hull of the ship.
• Integrate a Residual Current Device (RCD) in wiring of the AC output
Refer to local applicable regulations on these issues
Connect the incoming shore power to the AC input (INPUT). Phase line to L and Neutral to N.
Do NOT connect the ground wire (PE/GND) of the shore power to the central grounding point (hull of the ship), neither
to the PE/GND connection of the output!
NEDERLANDS: Sluit de belasting aan op de AC uitgang (OUTPUT). Voor een veilige installatie dient u:
• zowel de aarde (PE/GND) als de nul (N) van de uitgang van de IVET door te verbinden met het centraal aardpunt,
welke in verbinding moet staan met de romp van het schip.
• in het uitgangscircuit van de IVET een 30mA aardlekschakelaar op te nemen.
Raadpleeg hiertoe de plaatselijk geldende richtlijnen.
Sluit de bedrading naar de walstroom aan op de AC ingang (INPUT), fase op L en nul op N.
De aardedraad (PE/GND) van de walstroom mag niet aangesloten worden op het centraal aardpunt (romp van het
schip) of de PE/GND aansluiting van de AC-uitgang!
DEUTSCH: SchlieĂźen Sie die AC-Last an den AC-Ausgang (OUTPUT) an. FĂĽr eine sichere Installation ist es
erforderlich:
• sowohl die Erde (PE/GND) und den Nullleiter (N) des AC-Ausgangs des IVET an den zentralen Erdungspunkt
anzuschlieĂźen, der mit dem Rumpf des Schiffes verbunden ist.
• ein Reststromgerät (RCD) in der Verkabelung des AC-Ausgangs zu installieren.
Nehmen Sie hinsichtlich dieser Punkte Bezug auf die örtlich anwendbaren Vorschriften.
SchlieĂźen Sie den eingehenden Landstrom an den AC-Eingang (INPUT) an, die Phasenleitung an L und den Nullleiter
an N.
SchlieĂźen Sie den Erdungsdraht (PE/GND) des Landstroms NICHT an den zentralen Erdungspunkt (Schiffsrumpf) an
und ebenfalls nicht an den PE/GND-Anschluss des Ausgangs!
FRANÇAIS : Raccorder la charge CA à la sortie CA (OUTPUT). Pour sécuriser l'installation, vous devez :
• Raccorder à la fois la terre (Mise à la terre) et le neutre (N) de la sortie CA de l’IVET au point de masse central
connecté à la coque du bateau.
• Intégrer un dispositif de courant résiduel (DCR) dans le câblage de la sortie CA.
Se référer à ce sujet aux réglementations locales en vigueur
Connecter l'alimentation quai entrante à l'entrée CA (INPUT). La ligne de phase au L et le Neutre au N.
Ne PAS connecter le fil de terre (Mise Ă  la terre) de l'alimentation quai au point de masse central (coque du bateau), ni
Ă  la connexion Mise Ă  la terre de la sortie !
Only allow changes in your electrical system to be carried out by qualified electricians!
Laat veranderingen aan uw elektrische installatie alleen door gekwalificeerde elektriciens uitvoeren!
Sie sollten Ă„nderungen Ihres Elektrosystems nur von qualifizierten Elektrikern durchfĂĽhren lassen!
Seuls des électriciens qualifiés peuvent apporter des modifications à votre système électrique !
SPECIFICATIONS
IVET w/o Cabinet (IP00) 2.5 kVA up to 22 kVA
IVET in Dakar cabinet (IP23) 2.5 kVA up to 4.5 kVA
IVET in Steel plate cabinet (IP23) 6.0 kVA up to 22 kVA
Produced according to: VDE 0550, VDE 0532
Isolation class: T 40/E
Transformer type: E-core
Input voltage: 110 – 220 – 240 Volt
Output voltage: 110 – 220 – 240 Volt
Phase: 1
Input frequency: 50 / 60Hz
Output frequency: Same as input frequency
Cooling: Natural convection
Automatic voltage selector No (optional)
Soft start included No (optional)
Circuit breaker included No Dimensions of the E-core transformer IVET without cabinet
Mastervolt International B.V, P.O.Box 22947, NL-1100 DK Amsterdam, The Netherlands. Tel.: +31-20-3422100 Email: info@mastervolt.com Web: www.mastervolt.com v2.0 060901
Installation
Installation Installatie
Installation IVET
IVET transformers without cabinet (IP00)
Part number Model Power rating Weight Dimensions h x w x d (see drawing on previous page)
85000250 IVET 2.5 2.5 kVA 22 kg / 49 lbs 330 x 200 x 160 mm / 13.0 x 7.9 x 6.3 inch
85000350 IVET 3.5 3.5 kVA 30 kg / 66 lbs 330 x 200 x 185 mm / 13.0 x 7.9 x 7.3 inch
85000450 IVET 4.5 4.5 kVA 35 kg / 77 lbs 380 x 240 x 185 mm / 15.0 x 9.4 x 7.3 inch
85000600 IVET 6.0 6.0 kVA 50 kg / 110 lbs 380 x 240 x 215 mm / 15.0 x 9.4 x 8.5 inch
85000800 IVET 8.0 8.0 kVA 59 kg / 130 lbs 430 x 280 x 210 mm / 16.9 x 11.0 x 8.3 inch
85001000 IVET 10.0 10.0 kVA 75 kg / 165 lbs 430 x 280 x 240 mm / 16.9 x 11.0 x 9.4 inch
85001300 IVET 13.0 13.0 kVA 90 kg / 198 lbs 490 x 320 x 230 mm / 19.3 x 12.6 x 9.2 inch
85001800 IVET 18.0 18.0 kVA 110 kg / 243 lbs 490 x 320 x 260 mm / 19.3 x 12.6 x 10.2 inch
85002200 IVET 22.0 22.0 kVA 130 kg / 287 lbs 490 x 320 x 290 mm / 19.3 x 12.6 x 11.4 inch
IVET transformers in cabinet IVET
Part number
w/o softstart Part number
with softstart Model Power rating Weight Dimensions H x W x D
86030250 86040250 IVET 2.5 in cabinet Dakar D2 2.5 kVA 29 kg / 64 lbs 500 x 363 x 253 mm / 19.7 x 14.3 x 10.0 inch
86030350 86040350 IVET 3.5 in cabinet Dakar D2 3.5 kVA 37 kg / 82 lbs 500 x 363 x 253 mm / 19.7 x 14.3 x 10.0 inch
86030450 86040450 IVET 4.5 in cabinet Dakar D2 4.5 kVA 44 kg / 97 lbs 500 x 363 x 253 mm / 19.7 x 14.3 x 10.0 inch
Part number Model Power rating Weight Dimensions H x W x D
86000600 IVET 6.0 in cabinet w/o softstart 6.0 kVA 72 kg / 159 lbs 520 x 520 x 500 mm / 20.5 x 20.5 x 19.7 inch
86000800 IVET 8.0 in cabinet w/o softstart 8.0 kVA 81 kg / 179 lbs 520 x 520 x 500 mm / 20.5 x 20.5 x 19.7 inch
86001000 IVET 10.0 in cabinet w/o softstart 10.0 kVA 97 kg / 214 lbs 520 x 520 x 500 mm / 20.5 x 20.5 x 19.7 inch
86001300 IVET 13.0 in cabinet w/o softstart 13.0 kVA 117 kg / 258 lbs 590 x 580 x 550 mm / 23.2 x 22.8 x 21.7 inch
86001800 IVET 18.0 in cabinet w/o softstart 18.0 kVA 137 kg / 302 lbs 590 x 580 x 550 mm / 23.2 x 22.8 x 21.7 inch
86002200 IVET 22.0 in cabinet w/o softstart 22.0 kVA 157 kg / 346 lbs 590 x 580 x 550 mm / 23.2 x 22.8 x 21.7 inch
Mastervolt International B.V, P.O.Box 22947, NL-1100 DK Amsterdam, The Netherlands. Tel.: +31-20-3422100 Email: info@mastervolt.com Web: www.mastervolt.com v2.0 060901
10
9
8
7
6
5
4
3
2
1
INPUT OUTPUT
N
L
N
L2
4
3
5
7
9
8
10
OUTPUT INPUT
16
INPUT: 110V
OUTPUT: 110V
120V
NL N L
10
9
8
7
6
5
4
3
2
1
INPUT OUTPUT
N
L
N
L2
4
3
5
7
9
8
10
OUTPUT INPUT
16
INPUT: 220V
OUTPUT: 110V
120V
NL N L
10
9
8
7
6
5
4
3
2
1
INPUT OUTPUT
N
L
N
L2
4
3
5
7
9
8
10
16
INPUT: 110V
OUTPUT: 220V
240V
NL N L
OUTPUT INPUT
10
9
8
7
6
5
4
3
2
1
INPUT OUTPUT
N
L
N
L2
4
3
5
7
9
8
10
16
INPUT: 220V
OUTPUT: 220V
240V
NL N L
OUTPUT INPUT
7
9
8
10
2
4
3
5
61


Product specificaties

Merk: Mastervolt
Categorie: Acculader
Model: IVET 6

Heb je hulp nodig?