Masport Clunes Handleiding

Masport Heater Clunes

Lees hieronder de 📖 handleiding in het Nederlandse voor Masport Clunes (17 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/17
WOOD FIRE
OWNERS MANUAL
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. For assistance or additional information consult an authorized technician, or your Wood Fire Dealer.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this appliance. Installation and service must be performed by authorized personnel.
INSTALLATION OF YOUR WOODFIRE: Please refer to the Installation Manual and Installation
Specification Sheets specific for your model.
PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE.
Manufactured in New Zealand by: Distributed in Australia by:
GLEN DIMPLEX NEW ZEALAND LIMITED GLEN DIMPLEX AUSTRALIA PTY LIMITED
P.O.Box 58473, Botany, Manukau - 2163 1340 Ferntree Gully Road, Scoresby, Victoria 3179
Ph: 0800 666 2824 Ph: 1 300 554 155
Fax: 09 274 8472 Fax: 1 800 058 900
Email: sales@glendimplex.co.nz Email: sales@glendimplex.com.au
Web: www.glendimplex.co.nz Web: www.glendimplex.com.au
1
st
Feb 2018 Part No.593286
1
CONTENTS
OPERATING INSTRUCTIONS
FOR ALL MODELS
PAGE
INTRODUCTION 2
BASIC INFORMATION 3
LIGHTING UP 4
OPERATING HINTS 5
SAFETY 6
MAINTENANCE 7
BEFORE EACH HEATING SEASON 9
FAN WIRING DIAGRAMS 10
PROBLEM SOLVING 12
WARRANTY REGISTRATION FORM 14
WARRANTY TERMS & CONDITIONS 16
THIS MANUAL CONTAINS IMPORTANT INFORMATION.
PLEASE KEEP IT IN A SAFE PLACE FOR FUTURE REFERENCE.
2
INTRODUCTION
In the interests of your safety, all building regulatory Authorities in Australia and New
Zealand require any wood fire installation to comply with Installation Standard AS/NZS
2918. They may also have local requirements in addition to those in the Standard.
Check with your local Building Authority before commencing installation, to find
if you will require a Permit and whether there are extra requirements
.
All our
Wood fires have been tested to ensure that they will meet the appropriate safety
Standard requirements if the instructions in this book and additional instructions supplied
with the fire are followed. As the safety and emissions performance can be affected by
altering the appliance, no modifications are allowed without written permission from the
manufacturer.
Wood fire models covered by this manual have been tested to demonstrate compliance
with current general emission requirements in Australia and New Zealand, but some
areas have stricter limits. Only some of the models meet those limits, so check before
installing a particular model. In areas covered by stricter emission regulations:
(I) If a water-heating device is permitted, it must be factory fitted or be a genuine
accessory retrofitted strictly in accordance with the instructions supplied by Glen Dimplex
New Zealand Ltd or Glen Dimplex Australia Pty Ltd.
(II) Coal must not be used as a fuel unless it is a multi fuel fire.
(III) Wood fuel must have a moisture content of less than 25%.
WE RECOMMEND THAT THE INSTALLATI ON OF YOUR WOODFIRE BE
CARRIED OUT BY A QUALIFIED SPECIALIST INSTALLER.
WARNING: IF ANY ELECTRICAL WORK IS REQUIRED, IT MUST BE CARRIED OUT BY A
LICENSED ELECTRICIAN.
WARNING: IN SOME REGIONS POWER POINTS ARE NOT PERMISSIBLE WITHIN THE
FLOOR PROTECTOR AREA; PLEASE CHECK WITH YOUR LOCAL AUTHORITY.
WARNING: FOR APPLIANCES WITH WATER HEATING DEVICES: DO NOT CONNECT
TO AN UNVENTED HOT WATER SYSTEM. INSTALL IN ACCORDANCE WITH AS
3500.4.1 OR NZS 4603 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT
BUILDING CODE/S.
WARNING: IN NEW ZEALAND, FAN & WATER HEATING DEVICE CAN BE INSTALLED
ONLY FOR RURAL APPLICATION EXCEPT, INSERT MODEL MASPORT LE4000
PROVINCIAL, WHICH IS TESTED WITH FAN & FAN MUST BE INSTALLED BY A
REGISTERED ELECTRICIAN. INSERT MODEL I3000 WET, WHICH IS TESTED WITH
WATER HEATING DEVICE. BOTH THESE MODELS ARE AUTHORIZED BY ECAN.
WARNING: TO AVOID THE RISK OF ELECTRIC SHOCK OR CONTACT WITH MOVING
PARTS, ONLY THE MANUFACTURER AUTHORIZED SERVICE AGENTS OR
SIMILARLY QUALIFIED PERSONS SHOULD REMOVE THE BOTTOM PANELS
WHICH ALLOW ACCESS TO FANS.
WARNING: THE APPLIANCE AND FLUE SYSTEM MUST BE INSTALLED IN
ACCORDANCE WITH AS/NZS 2918:2001 AND THE APPROPRIATE REQUIREMENTS
OF THE LOCAL AUTHORITY BUILDING CODE OR CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD
SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED
BY THE REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE
IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING ‘TESTED TO
AS/NZS 4013’. ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITNG BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN
BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013.
CAUTION: Please ensure that only components approved by Glen Dimplex are used for the
installation, as substitutes may adversely affect performance and might nullify
compliance with the requirements of AS/NZS 2918.
CAUTION: Mixing of appliance or flue system components from different sources or
modifying the dimensional specification of components may result in hazardous
conditions. Where such action is considered, the manufacturer should be consulted in the
first instance.
CAUTION: Cracked/broken components e.g. door glass, makes the installation unsafe.


Product specificaties

Merk: Masport
Categorie: Heater
Model: Clunes

Heb je hulp nodig?

Als je hulp nodig hebt met Masport Clunes stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Masport

Handleiding Heater

Nieuwste handleidingen voor Heater