Marmitek XM10 Diversen Handleiding

Marmitek Diversen XM10 Diversen

Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor Marmitek XM10 Diversen (11 pagina's) in de categorie Diversen. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/11
X-10 protocol for the Marmitek XM10 OEM Controller
Marmitek XM10 OEM Controller
*O.E.M Original Equipment Manufacturer
Safety Warnings
x The wiring of your electrical installation is live (230 V) and extremely dangerous. Never connect
the module when plugged into the mains. Always turn off the main switch before starting the
installation.๎€ƒ
x To prevent short circuits, this product should only be used inside and only in dry spaces. Do not
expose the components to rain or moisture. Do not use the product close to a bath, swimming
pool etc.
x Do not expose the components of your systems to extremely high temperatures or bright light
sources.
x Do not open the product: the device contains live parts. The product should only be repaired or
serviced by a qualified repairman
xIn case of improper usage or if you have opened, altered and repaired the product yourself, all
guarantees expire. Marmitek does not accept responsibility in the case of improper usage of the
product or when the product is used for purposes other than specified. Marmitek does not accept
responsibility for additional damage other than covered by the legal product responsibility.
How to implement
Two - way PLC interface for OEM applications (XM10)
The XM10 is a transmitter-receiver that plugs into a regular AC outlet and connects to the controller via a
modular RJ 11 telephone jack. Alternatively, the XM10 may be fitted inside the controller cabinet,
connected to the 230 V AC supply before the power transformer. (This would be a typical installation with
most security panels.)
It provides an opto-coupled 50 Hz. Square wave, synchronised to the zero crossing point of the AC line.
The controller generates X-10 compatible codes synchronised to this zero crossing point. The two-way
interface then couples the X-10 codes onto the AC line.
Two - Way transmission available
The two-way interface transmits and receives X-10 codes. It enables an O.E.M. to develop a system to
control X-10 Modules, and receive X-10 signals from remote sensors (P.I.R. motion detectors for example)
X-10 Code transmission
To transmit X-10 signals the controller must supply 1 ms .envelopes. to the TX input of the interface with
respect to common. These envelopes must be as close as possible to the zero crossing point of the AC
line (see timing diagrams). An opto- coupled output representing the zero crossing point of the power line
is provided for the controller to which X-10 codes are to be synchronised.
X-10 Code reception
The two-way interface uses a custom proprietary I.C. to read X-10 codes from the power line. This takes
a lot of burden off the microprocessor in the controller as it does not have to continuously monitor the
powerline and check all in coming signals (and noise) for validity. Any signals applied to the controller are
error-checked, valid X-10 codes. When a valid X-10 code is received, it is stored in the custom I.C. and
- 1 -
X-10 protocol for the Marmitek XM10 OEM Controller
applied (in envelope form) to the controller. This output is coincident with the second X-10 transmission.
(X-10 codes are always transmitted in groups of two, except for Bright and Dim.)
Data sent to the controller is valid X-10 data. The start Code (1110) can be used to alert the controller that
an X-10 Code will follow. A .1. bit from the two-way interface appears as a negative going pulse 1.1 ms
long, beginning approximately 100 ยตs after zero crossing. The controller should sample this data between
500 and 700 ยตs after zero crossing.
The L.E.D. on the two-way interface gives a visual indication that X-10 codes are being received. The
L.E.D. is illuminated when AC power is applied to the two-way interface and blinks off when X-10 codes
are received. The two-way interface will also receive the codes it transmits, therefore the L.E.D. will also
give an indication of codes being transmitted.
The ability to read X-10 codes from its own output also allows the controller to incorporate data collision
detection. If the code received differs from the code transmitted, the code can be assumed to have been
corrupted by noise ( or another transmission ) on the power line.
The line Monitor capability of the two-way interface allows the controller to ensure that the power line is
free from X-10 signals before starting a transmission. This means that in a multitransmitter system the
controller can minimise contention between transmitters. For example, if after detecting that the line is
free, a transmitter waits for a random number of power line half cycles before transmitting, the chance of
collision is reduced. A different priority can be assigned to each transmitter by including a fixed delay
before the random delay. The shorter the fixed delay, the higher the priority.
Important Safety Notice
Zero volts in this product is directly connected to one side of the AC line.
Therefore, for safety, an ISOLATING power transformer MUST be used when attempting any internal
measurements.
The power supply in the two-way interface are capacitively derived from, and directly referenced to, the
230V AC power line. Care should be taken when monitoring any internal circuitry with an oscilloscope, as
the OV reference in the two-way interface are NOT isolated from 230 volts.
X-10 Protocol
The tables in Figure 1, show the Binary Codes to be transmitted for each House. Code and Key Code.
The Start Code is Always 1110 which is a unique code and is the only code which does not follow the
truecomplement relationship on alternate half cycles.
- 2 -
X-10 protocol for the Marmitek XM10 OEM Controller
Figure 1
House Code and Key Code Tables
House Code Key Codes
H8H4H2H1D8D4D2D1D16
A0110101100
B1110211100
C0010300100
D1010410100
E0001500010
F1001610010
G0101701010
H1101811010
I0111901110
J11111011110
K00111100110
L10111210110
M00001300000
N10001410000
O01001501000
P11001611000
All units off 0 0 0 0 1
All lights on 0 0 0 1 1
On 0 0 1 0 1 (shutters open)
Off 0 0 1 1 1 (shutters close)
Dim 0 1 0 0 1 (shutters up)
Bright 0 1 0 1 1 (shutters down)
All Lights Off 0 1 1 0 1
Extended Code (1) 0 1 1 1 1 (for data/control)
Hail Request 1 0 0 0 1
Hail Acknowledge 1 0 0 1 1
Extended Code (3) 1 0 1 0 1 (for security messages)
Program 1 0 1 1 1
Extended Code (2) 1 1 0 0 1 (for meter read & dsm)
Status = on 1 1 0 1 1
Status = off 1 1 1 0 1
Status Request 1 1 1 1 1
(1) Hail Request is transmitted to see if there are any other X-10 transmitters within listening range. This
allows the O.E.M to assign a different House code if a .Hail Acknowledge. is received.
(2) In a Pre-Set Dim instruction, the D8 bit represents the Most Significant Bit of the level and H1, H2, H4
and H8 bits represent the 4 Least Significant Bits.
(3) The Extended Data code is followed by 8 bit bytes which can represent Analog data (after A to D
conversion). There should be no gaps between the Extended Data code and the actual data, and no
gaps between data bytes. The first 8 bit byte can be used to say how many bytes of data will follow. If
gaps are left between data bytes, these codes could be received by X-10 Modules causing erroneous
operation.
Extended Code is similar to Extended Data: 8 Bit bytes which follow Extended Code (with no gaps) can
represent additional codes. This allows the designer to expand beyond the 256 codes presently available.
- 3 -


Product specificaties

Merk: Marmitek
Categorie: Diversen
Model: XM10 Diversen

Heb je hulp nodig?

Als je hulp nodig hebt met Marmitek XM10 Diversen stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Diversen Marmitek

Handleiding Diversen

Nieuwste handleidingen voor Diversen