Makita JR3061T Handleiding


Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor Makita JR3061T (8 pagina's) in de categorie Zaagmachine. Deze handleiding was nuttig voor 39 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
INSTRUCTION MANUAL
Recipro Saw
JR3061T
ENGLISH: Original instructions
DOUBLE INSULATION
Read before use.
2 ENGLISH
SPECIFICATIONS
Model: JR3061T
Length of stroke 32 mm
Strokes per minute 0 - 3,000 min-1
Max. cutting capacities Pipe
(with 300 mm blade)
130 mm
Wood
(with 305 mm blade)
255 mm
Overall length 487 mm
Net weight 3.8 kg
Safety class /II
โ€ข๎€ƒ Due๎€ƒto๎€ƒour๎€ƒcontinuing๎€ƒprogram๎€ƒof๎€ƒresearch๎€ƒand๎€ƒdevelopment,๎€ƒthe๎€ƒspeci๎‚ฟcations๎€ƒherein๎€ƒare๎€ƒsubject๎€ƒto๎€ƒchange๎€ƒ
without notice.
โ€ข๎€ƒ Speci๎‚ฟcations๎€ƒmay๎€ƒdiffer๎€ƒfrom๎€ƒcountry๎€ƒto๎€ƒcountry.
โ€ข Weight according to EPTA-Procedure 01/2014
Symbols
The followings show the symbols used for the equip-
ment. Be sure that you understand their meaning before
use.
Read instruction manual.
DOUBLE INSULATION
Only for EU countries
Do not dispose of electric equipment
together with household waste material! In
observance of the European Directive, on
Waste Electric and Electronic Equipment
and its implementation in accordance with
national law, electric equipment that have
reached the end of their life must be col-
lected separately and returned to an envi-
ronmentally compatible recycling facility.
Intended use
The tool is intended for sawing wood, plastic, metal and
building materials with a strong impact. It is suitable for
straight and curved cutting.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
Noise
The typical A-weighted noise level determined accord-
ing to EN62841-2-11:
Sound pressure level (LpA) : 88 dB(A)
Sound power level (LWA) : 99 dB (A)
Uncertainty (K) : 3 dB(A)
NOTE: The declared noise emission value(s) has
been measured in accordance with a standard test
method and may be used for comparing one tool with
another.
NOTE: The declared noise emission value(s)
may also be used in a preliminary assessment of
exposure.
WARNING: Wear ear protection.
WARNING: The noise emission during actual
use of the power tool can differ from the declared
value(s) depending on the ways in which the
tool is used especially what kind of workpiece is
processed.
WARNING: Be sure to identify safety mea-
sures to protect the operator that are based on an
estimation of exposure in the actual conditions of
use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
Vibration
The vibration total value (tri-axial vector sum) deter-
mined according to EN62841-2-11:
Work mode: cutting boards
Vibration emission (a
h,B ) : 18.5 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: cutting wooden beams
Vibration emission (a
h,WB) 16.5 m/s2
Uncertainty (K) : 2.0 m/s
2
NOTE: The declared vibration total value(s) has been
measured in accordance with a standard test method
and may be used for comparing one tool with another.
NOTE: The declared vibration total value(s) may also
be used in a preliminary assessment of exposure.
3 ENGLISH
WARNING:
The vibration emission during actual
use of the power tool can differ from the declared val-
ue(s) depending on the ways in which the tool is used
especially what kind of workpiece is processed.
WARNING:
Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (tak-
ing account of all parts of the operating cycle such
as the times when the tool is switched off and when
it is running idle in addition to the trigger time).
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING:
Read all safety warnings, instruc-
tions, illustrations and speci๎‚ฟcations provided with this
power tool. Failure to follow all instructions listed below
may๎€ƒresult๎€ƒin๎€ƒelectric๎€ƒshock,๎€ƒ๎‚ฟre๎€ƒand/or๎€ƒserious๎€ƒinjury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1. Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
2. Do not operate power tools in explosive atmo-
spheres, such as in the presence of ๎ƒ€ammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
3. Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.
Electrical safety
1. Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodi๎‚ฟed๎€ƒplugs๎€ƒand๎€ƒmatching๎€ƒoutlets๎€ƒwill๎€ƒ
reduce risk of electric shock.
2. Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of elec-
tric shock if your body is earthed or grounded.
3. Do not expose power tools to rain or wet con-
ditions. Water entering a power tool will increase
the risk of electric shock.
4. Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled cords
increase the risk of electric shock.
5. When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
6. If operating a power tool in a damp location
is unavoidable, use a residual current device
(RCD) protected supply. Use of an RCD reduces
the risk of electric shock.
7. Use of power supply via an RCD with a rated
residual current of 30 mA or less is always
recommended.
8.
Power tools can produce electromagnetic ๎‚ฟelds
(EMF) that are not harmful to the user. However,
users of pacemakers and other similar medical
devices should contact the maker of their device and/
or doctor for advice before operating this power tool.
9. Do not touch the power plug with wet hands.
10. If the cord is damaged, have it replaced by the
manufacturer or his agent in order to avoid a
safety hazard.
Personal safety
1. Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or
under the in๎ƒ€uence of drugs, alcohol or med-
ication. A moment of inattention while operating
power๎€ƒtools๎€ƒmay๎€ƒresult๎€ƒin๎€ƒserious๎€ƒpersonal๎€ƒinjury.
2. Use personal protective equipment. Always
wear eye protection. Protective equipment such
as a dust mask, non-skid safety shoes, hard hat or
hearing protection used for appropriate conditions
will๎€ƒreduce๎€ƒpersonal๎€ƒinjuries.
3. Prevent unintentional starting. Ensure the
switch is in the off-position before connecting
to power source and/or battery pack, picking
up or carrying the tool. Carrying power tools with
your๎€ƒ๎‚ฟnger๎€ƒon๎€ƒthe๎€ƒswitch๎€ƒor๎€ƒenergising๎€ƒpower๎€ƒtools๎€ƒ
that have the switch on invites accidents.
4. Remove any adjusting key or wrench before
turning the power tool on. A wrench or a key left
attached to a rotating part of the power tool may
result๎€ƒin๎€ƒpersonal๎€ƒinjury.
5. Do not overreach. Keep proper footing and
balance at all times. This enables better control
of the power tool in unexpected situations.
6. Dress properly. Do not wear loose clothing or
jewellery. Keep your hair and clothing away
from moving parts.๎€ƒLoose๎€ƒclothes,๎€ƒjewellery๎€ƒor๎€ƒ
long hair can be caught in moving parts.
7. If devices are provided for the connection of
dust extraction and collection facilities, ensure
these are connected and properly used. Use of
dust collection can reduce dust-related hazards.
8.
Do not let familiarity gained from frequent use
of tools allow you to become complacent and
ignore tool safety principles. A careless action can
cause๎€ƒsevere๎€ƒinjury๎€ƒwithin๎€ƒa๎€ƒfraction๎€ƒof๎€ƒa๎€ƒsecond.
9. Always wear protective goggles to protect
your eyes from injury when using power tools.
The goggles must comply with ANSI Z87.1 in
the USA, EN 166 in Europe, or AS/NZS 1336
in Australia/New Zealand. In Australia/New
Zealand, it is legally required to wear a face
shield to protect your face, too.


Product specificaties

Merk: Makita
Categorie: Zaagmachine
Model: JR3061T

Heb je hulp nodig?

Als je hulp nodig hebt met Makita JR3061T stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Zaagmachine Makita

Handleiding Zaagmachine

Nieuwste handleidingen voor Zaagmachine