Livex Lighting Jefferson 5082-04 Handleiding

Livex Lighting Verlichting Jefferson 5082-04

Lees hieronder de đź“– handleiding in het Nederlandse voor Livex Lighting Jefferson 5082-04 (1 pagina's) in de categorie Verlichting. Deze handleiding was nuttig voor 6 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
ASSEMBLING &
INSTALLATION INSTRUCTIONS
PRODUCT# JEFFERSON SERIES
FOR CEILING MOUNT FIXTURE
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
Fig.1
Junction Box
Single bar
(GND)
A
Screw Box
D
B
C
E
F
H
G
MOUNTING THE FIXTURE (Fig.1)
1. Shut off the power at the circuit breaker box. Remove old
fixture and all hardware from Junction Box.
2. Carefully unpack your new fixture and lay out all the parts
on a clear area. Take care not to lose any small parts
necessary for installation.
3. Thread the two mounting screws about 1/4” into the
pre-drilled holes in the single bar spaced the same distance
apart as the holes in the fixture canopy (A).
4. Install the single bar to the Junction Box with the two
Junction Box Screws as shown. The side of the single bar
marked "GND" must face out.
5. While holding the column assembly towards the ceiling,
connect the electrical wires as Shown in Fig.2, making
sure that all wire nuts are secured. You may have to wrap
the connections with electrical tape. If your outlet has a
ground wire (green or bare copper), connect the fixture
ground wire to it. Otherwise connect fixture’s ground wire
directly to the Mounting strap with the green screw
provided. After wires are connected, tuck them carefully
inside the Junction Box.
6. Attach the pipe nipple(C) to top coupling of the lamp
holder(F) and lock it until tight. Attach the canopy(A)
onto the pipe nipple(C) and lock it until tight.
7. Place the candle sleeve (E) onto the lamp holder(F).
8. Install the light bulbs in accordance with the fixture
specifications NOTE: DO NOT EXCEED THE
SPECIFIED WATTAGE!
9. Attach the bell glass(H) insert to the big ring(G). While
holding the big ring(G) and canopy(A), hooked by the hook
at both of the pipe(D).
10. Attach the canopy(A) to the Junction box, aligning screws
on single bar with mounting holes in canopy and lock it
securely with ball nut (B).
Your installation is now complete Return power
to the junction box and test the fixture.
Fig.2
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE
WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE
WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES
White
Bare
Green or
WIRES
HOUSE


Product specificaties

Merk: Livex Lighting
Categorie: Verlichting
Model: Jefferson 5082-04

Heb je hulp nodig?

Als je hulp nodig hebt met Livex Lighting Jefferson 5082-04 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verlichting Livex Lighting

Handleiding Verlichting

Nieuwste handleidingen voor Verlichting