M O U N T I N G A N D C O N N E C T I N G T H E D E V I C E
T E C H N I C A L D E T A I L S
Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
Power consumption Max. ca. 18 W
Environment Temperature range 0–40 °C; humidity 0–95 %; non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; mea-
sures 210 x 45 x 140 mm (W x H x D)
Number of fans One quiet fan
Interfaces
WAN: VDSL2 aVDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b
aVDSL2 vectoring as per ITU G.993.5 (G.vector)
aCompatible to VDSL2 from Deutsche Telekom
aVDSL Supervectoring as per ITU G.993.2 (Annex Q)
aCompatible to U-R2 from Deutsche Telekom (1TR112)
aADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1
aSupports just one virtual connection at a time in ATM (VPI-VCI pair)
Wi-Fi aFrequency band: 2400-2483.5 MHz (ISM) or 5150-5825 MHz (restrictions vary between
countries)
aRadio channels 2.4 GHz: Up to 13 channels, max. 3 non-overlapping (2.4-GHz band)
aRadio channels 5 GHz: Up to 26 non-overlapping channels (channels available vary
according to country regulations; DFS for automatic dynamic channel selection required)
ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically
disabled in the LCOS configuration.
USB USB 2.0 hi-speed host port for connecting USB printers (USB print server),
serial devices (COM-port server) or USB drives (FAT file system)
ISDN 1 / ISDN 2 ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS.
ISDN 2: Internal (NT) ISDN bus.
Analog 1 / Analog 2
Analog 3 / Analog 4
Use the cable of your analog devices to connect them with the analog interfaces. If necessary
use the adapters from the LANCOM Analog Adapter Set.
Config (Com) / V.24 Serial configuration interface/COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable for
optional connection of analog/GPRS modems. Supports internal COM-port server and provides
transparent asynchronous serial-data transfer via TCP.
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
DHCP), RIP-1, RIP-2, VLAN
ISDN DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD
Declaration of Conformity
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in
compliance with Directives 2014/30/EU, 2014/53/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006.
The full text of the EU Declaration of Conformity is available at the following Internet address:
www.lancom-systems.com/doc
Package content
Manual Quick Reference Guide (DE/EN); Installation Guide (DE/EN)
Cable 1 DSL cable for an IP-based line, 4.25 m
Adapters 2 TAE adapters (RJ11 - TAE)
Power adapter External power supply adapter (230 V); NEST 12 V / 2 A DC/S; barrel / bayonet (EU),
LANCOM item no. 111303
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device firmware (LCOS) is available on the device‘s
WEBconfig interface under “Extras > License information“. If the respective license demands, the source files for the
corresponding software components will be made available on a download server upon request.
i VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, flashing VPN connecting
e ISDN
Off Interface deactivated
Green, permanently D-channel active
Green, flickering ISDN data transfer
Red, flickering ISDN transfer error
Red / orange, blinking ISDN hardware error
b Online
Off WAN connection inactive
Green, permanently WAN connection active
Red, permanently WAN connection error
c DSL
Off Interface deactivated
Green, permanently DSL connection active
Green, flickering DSL data transfer
Red, flickering DSL transfer error
Red / orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
Green, blinking DSL connecting
d Analog
Off Interface deactivated
Green, permanently Interface activated
Orange, blinking Incoming call
Green, blinking Connection active
h VoIP
Off No SIP accounts defined or VCM is off
Green, permanently All defined and active SIP accounts
(outgoing) were successfully registered
Red, permanently Not all defined and active SIP accounts
were registered (possibly still in process)
Red or green,
inverse flashing
Number of currently used lines (connecting
or connected)
f ETH
Off No networking device attached
Green, permanently Connection to network device operational,
no data traffic
Green, flickering Data transmission
g WLAN
Off No Wi-Fi network defined or Wi-Fi module
deactivated. The Wi-Fi module is not
transmitting beacons.
Green, permanently At least one Wi-Fi network is defined and
Wi-Fi module activated. The Wi-Fi module
is transmitting beacons.
Green, blinking DFS scanning or other scan procedure
j Reset
Reset button Operated e.g. with a paper clip
ashort press: Restart the device
along press: Reset the device
a Power
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Red / green blinking Configuration password not set. Without a
configuration password, the configuration
data in the device is unprotected.
Red blinking Charge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
aVDSL interface
Use the supplied DSL cable for the IP-based line to connect the
VDSL interface and the provider’s telephone socket. For more
infor mation, please contact your Internet service provider.
bEthernet interfaces
Use an Ethernet cable to connect one of the interfaces ETH 1 to
ETH4 to your PC or a LAN switch.
cAnalog interfaces
Connect analog terminal devices to the analog interfaces either
directly via RJ11, or with the help of the enclosed TAE adapters.
Further adapters are optionally available.
dConfiguration interface
Use a serial configuration cable to connect the serial interface
(COM) to the serial interface of the device you want to use for
configuring / monitoring (separately available).
eISDN interfaces
ISDN 1:
Internal (NT) or external (TE) ISDN bus.
This feature is controlled by LCOS.
ISDN 2:
Internal (NT) ISDN bus.
A 100-Ohm resistor for line termination is
switchable in LCOS.
fUSB interface
You can use the USB interface to connect a USB printer or a
USB memory stick.
gPower
After connecting the cable to the device, turn the bayonet
connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
a b c d e f g
Gigabit Ethernet 10/100/1000
ISDN 1 ISDN 2
TE / NT NT
VDSL
Analog 1/3Analog 2/4
a c eb gfd ih j
LANCOM 883+ VoIP
LANCOM 883+ VoIP
Quick Reference Guide
C ud eadylo -r
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is configured to be managed by the LANCOM
Management Cloud.
4
Please observe the following when setting up the device
A Do not rest any objects on top of the device
A For devices to be operated on the desktop, please attach the
adhesive rubber footpads
AIn case of wall mounting, use the drilling template as supplied
AKeep the ventilation slots on the side of the device clear
of obstruction
ARack installation with the optional LANCOM Rack Mount
(separately available)
LANCOM 1681V
Power
VDSL
Onl ine
ETH 1
VPN
TH 3
ETH 4
Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.
LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This docu-
ment contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and / or omissions. 111906/11/21


Product specificaties

Merk: Lancom
Categorie: Niet gecategoriseerd
Model: 883+ VoIP

Heb je hulp nodig?

Als je hulp nodig hebt met Lancom 883+ VoIP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Lancom

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

MSW

MSW -HRH-600 Handleiding

5 November 2024
MSW

MSW -PCJ-302 Handleiding

5 November 2024
MSW

MSW -ETT-22 Handleiding

5 November 2024
DoorBird

DoorBird MTM56A Handleiding

5 November 2024
Hacienda

Hacienda PWB801 Handleiding

5 November 2024
Hacienda

Hacienda PWB802 Handleiding

5 November 2024
MSW

MSW -ECF1-01 Handleiding

5 November 2024
MSW

MSW -MWC-01 Handleiding

5 November 2024
MSW

MSW -TM01 Handleiding

5 November 2024