INSTRUCTION๎˜MANUAL
KEW MATE 2000A/2001A
DIGITAL MULTIMETER
WITH
AC/DC CLAMP SENSOR
KYORITSU ELECTRICAL INSTRUMENTS
WORKS, LTD.
๏ผ‘๏ผŽSAFETY WARNINGS
This๎˜instrument๎˜has๎˜been๎˜designed๎˜and๎˜tested๎˜according๎˜to๎˜IEC๎˜Publication๎˜61010:๎˜
Safety๎˜ Requirements๎˜for๎˜ Electronic๎˜Measuring๎˜ Apparatus.๎˜ ๎˜This๎˜ instruction๎˜manual๎˜
contains๎˜warnings๎˜ and๎˜safety๎˜ rules๎˜ which๎˜must๎˜ be๎˜observed๎˜ by๎˜the๎˜ user๎˜to๎˜ ensure๎˜
safe๎˜operation๎˜ of๎˜the๎˜ instrument๎˜and๎˜ to๎˜retain๎˜ it๎˜in๎˜safe๎˜ condition.๎˜๎˜ Therefore,๎˜read๎˜
through๎˜these๎˜operating๎˜instructions๎˜before๎˜starting๎˜using๎˜the๎˜instrument.
๎˜
WARNING
โ—
๎˜Read๎˜ through๎˜ and๎˜ understand๎˜ instructions๎˜ contained๎˜ in๎˜ this๎˜ manual๎˜ before๎˜
starting๎˜using๎˜the๎˜instrument.๎˜๎˜
โ—
๎˜Save๎˜and๎˜keep๎˜the๎˜manual๎˜handy๎˜to๎˜enable๎˜quick๎˜reference๎˜whenever๎˜necessary.๎˜
โ—
๎˜Be๎˜ sure๎˜ to๎˜ use๎˜ the๎˜ instrument๎˜ only๎˜ in๎˜ its๎˜ intended๎˜ applications๎˜ and๎˜ to๎˜ follow๎˜
measurement๎˜procedures๎˜described๎˜in๎˜the๎˜manual.๎˜
โ—
๎˜Be๎˜sure๎˜to๎˜understand๎˜and๎˜follow๎˜all๎˜safety๎˜instructions๎˜contained๎˜in๎˜the๎˜manual.
The๎˜instrument๎˜is๎˜to๎˜be๎˜used๎˜only๎˜in๎˜its๎˜intended๎˜applications.
Understand๎˜and๎˜follow๎˜all๎˜the๎˜safety๎˜instructions๎˜contained๎˜in๎˜the๎˜manual.
Failure๎˜ to๎˜ follow๎˜ the๎˜ instructions๎˜ may๎˜ cause๎˜ injury,๎˜ instrument๎˜ damage๎˜ and/or๎˜
damage๎˜ to๎˜ equipment๎˜ under๎˜ test.๎˜ Kyoritsu๎˜ is๎˜ by๎˜ no๎˜ means๎˜ liable๎˜ for๎˜ any๎˜ damage๎˜
resulting๎˜from๎˜the๎˜instrument๎˜in๎˜contradiction๎˜to๎˜this๎˜cautionary๎˜note.
Failure๎˜ to๎˜ follow๎˜ the๎˜ above๎˜ instructions๎˜ may๎˜ cause๎˜ injury,๎˜ damage๎˜ to๎˜ the๎˜ instrument๎˜
and/or๎˜damage๎˜to๎˜equipment๎˜under๎˜test.
The๎˜ symbol๎˜ ๎˜ indicated๎˜ on๎˜ the๎˜ instrument๎˜ means๎˜ that๎˜ the๎˜ user๎˜must๎˜ refer๎˜ to๎˜ related๎˜
parts๎˜of๎˜the๎˜manual๎˜for๎˜safe๎˜operation๎˜of๎˜ the๎˜instrument.๎˜๎˜Be๎˜sure๎˜to๎˜ carefully๎˜read๎˜the๎˜
instructions๎˜following๎˜each๎˜ ๎˜symbol๎˜in๎˜this๎˜manual.
DANGER
๎˜๎˜๎˜
is๎˜reserved๎˜for๎˜conditions๎˜and๎˜actions๎˜that๎˜are๎˜likely๎˜to๎˜cause๎˜serious๎˜or๎˜fatal๎˜injury.
WARNING
๎˜
is๎˜reserved๎˜for๎˜conditions๎˜and๎˜actions๎˜that๎˜can๎˜cause๎˜serious๎˜or๎˜fatal๎˜injury.
CAUTION
๎˜
๎˜๎˜is๎˜reserved๎˜for๎˜conditions๎˜and๎˜actions๎˜that๎˜can๎˜cause๎˜minor๎˜injury๎˜or๎˜instrument๎˜damage.
Following๎˜ symbols๎˜ are๎˜ used๎˜ on๎˜ the๎˜ instrument๎˜ and๎˜ in๎˜ the๎˜ instruction๎˜ manual.๎˜ Attention๎˜
should๎˜be๎˜paid๎˜to๎˜each๎˜symbol๎˜to๎˜ensure๎˜your๎˜safety.
Refer๎˜to๎˜the๎˜instructions๎˜in๎˜the๎˜manual.
This๎˜symbol๎˜is๎˜marked๎˜where๎˜the๎˜user๎˜must๎˜refer๎˜to๎˜the๎˜instruction๎˜manual๎˜so๎˜as๎˜not๎˜
to๎˜cause๎˜personal๎˜injury๎˜or๎˜instrument๎˜damage.
Indicates๎˜an๎˜instrument๎˜with๎˜double๎˜or๎˜reinforced๎˜insulation.
Indicates๎˜that๎˜this๎˜instrument๎˜can๎˜clamp๎˜on๎˜bare๎˜conductors๎˜when๎˜measuring
a๎˜voltage๎˜corresponding๎˜ to๎˜ the๎˜applicable๎˜Measurement๎˜category,๎˜which๎˜ is๎˜marked๎˜
next๎˜to๎˜this๎˜symbol
๏ผŽ
Indicates๎˜AC๎˜(Alternating๎˜Current)
๏ผŽ
Indicates๎˜DC๎˜(Direct๎˜Current).
Indicates๎˜AC๎˜and๎˜DC.
DANGER
โ—
๎˜Never๎˜ make๎˜ measurement๎˜ on๎˜ circuits๎˜ with๎˜ a๎˜ maximum๎˜ voltage๎˜ difference๎˜ of๎˜
600VAC/DC๎˜ or๎˜ greater๎˜ between๎˜ conductors๎˜ (300VAC/DC๎˜ or๎˜ greater๎˜ between๎˜ a๎˜
conductor๎˜and๎˜ground).๎˜
โ—
๎˜Do๎˜ not๎˜ attempt๎˜ to๎˜ make๎˜ measurement๎˜ in๎˜ the๎˜ presence๎˜ of๎˜ flammable๎˜ gasses.๎˜๎˜
Otherwise,๎˜ the๎˜ use๎˜ of๎˜ the๎˜ instrument๎˜ may๎˜ cause๎˜ sparking,๎˜ which๎˜ leads๎˜ to๎˜ an๎˜
explosion.๎˜๎˜
โ—
๎˜Never๎˜attempt๎˜to๎˜use๎˜the๎˜instrument๎˜if๎˜its๎˜surface๎˜or๎˜your๎˜hand๎˜is๎˜wet.๎˜๎˜
โ—
Do๎˜not๎˜exceed๎˜the๎˜maximum๎˜allowable๎˜input๎˜of๎˜measuring๎˜ranges.
โ—
๎˜Never๎˜open๎˜the๎˜battery๎˜compartment๎˜cover๎˜while๎˜making๎˜measurement.
โ—
๎˜Never๎˜ try๎˜ to๎˜ make๎˜ measurement๎˜ if๎˜ any๎˜ abnormal๎˜ conditions,๎˜ such๎˜ as๎˜ broken๎˜
Transformer๎˜jaws๎˜or๎˜case๎˜is๎˜noted.
โ—
๎˜The๎˜ instrument๎˜ is๎˜ to๎˜ be๎˜ used๎˜ only๎˜ in๎˜ its๎˜ intended๎˜ applications๎˜ or๎˜ conditions.๎˜
Otherwise,๎˜ safety๎˜ functions๎˜ equipped๎˜ with๎˜ the๎˜ instrument๎˜ doesn
๎ขŸ
t๎˜ work,๎˜ and๎˜
instrument๎˜damage๎˜or๎˜serious๎˜personal๎˜injury๎˜may๎˜be๎˜caused.
WARNING
โ—
๎˜Never๎˜ attempt๎˜ to๎˜ make๎˜ any๎˜ measurement,๎˜ if๎˜ any๎˜ abnormal๎˜ conditions๎˜ are๎˜ noted,๎˜
such๎˜as๎˜broken๎˜case,๎˜cracked๎˜test๎˜leads๎˜and๎˜exposed๎˜metal๎˜parts.๎˜๎˜๎˜
โ—
๎˜Do๎˜not๎˜turn๎˜the๎˜Function๎˜Selector๎˜Switch๎˜ while๎˜the๎˜test๎˜leads๎˜are๎˜connected๎˜to๎˜ the๎˜
circuit๎˜under๎˜test.๎˜
โ—
๎˜Do๎˜ not๎˜install๎˜ substitute๎˜ parts๎˜ or๎˜make๎˜ any๎˜ modification๎˜to๎˜ the๎˜ instrument.๎˜ ๎˜Return๎˜
the๎˜instrument๎˜to๎˜Kyoritsu๎˜or๎˜your๎˜distributor๎˜for๎˜repair๎˜or๎˜re-calibration.
โ—
๎˜Do๎˜not๎˜try๎˜to๎˜replace๎˜the๎˜batteries๎˜if๎˜the๎˜surface๎˜of๎˜the๎˜instrument๎˜is๎˜wet.๎˜
โ—
๎˜Always๎˜ disconnect๎˜the๎˜ clamp๎˜sensor๎˜ and๎˜the๎˜ test๎˜leads๎˜ from๎˜ the๎˜circuit๎˜ under๎˜test๎˜
and๎˜ switch๎˜ off๎˜ the๎˜ instrument๎˜ before๎˜ opening๎˜ the๎˜ battery๎˜ compartment๎˜ cover๎˜ for๎˜
battery๎˜replacement.
โ—
๎˜Stop๎˜using๎˜the๎˜test๎˜lead๎˜if๎˜the๎˜outer๎˜jacket๎˜ is๎˜damaged๎˜and๎˜the๎˜inner๎˜metal๎˜or๎˜color๎˜
jacket๎˜is๎˜exposed.
CAUTION
โ—
๎˜Make๎˜sure๎˜that๎˜the๎˜Function๎˜Selector๎˜Switch๎˜is๎˜set๎˜to๎˜an๎˜appropriate๎˜position๎˜before๎˜
making๎˜measurement.
โ—
๎˜Always๎˜ make๎˜ sure๎˜ to๎˜ place๎˜ the๎˜ test๎˜ leads๎˜ in๎˜ the๎˜ test๎˜ lead๎˜ holder๎˜ before๎˜ making๎˜
current๎˜measurement.๎˜
โ—
Do๎˜not๎˜expose๎˜the๎˜instrument๎˜to๎˜the๎˜direct๎˜sun,๎˜extreme๎˜temperatures๎˜or๎˜dew๎˜fall.๎˜๎˜
โ—
๎˜Be๎˜sure๎˜ to๎˜set๎˜ the๎˜Function๎˜Selector๎˜ Switch๎˜to๎˜the๎˜ "OFF"๎˜position๎˜ after๎˜use.๎˜When๎˜
the๎˜ instrument๎˜ will๎˜ not๎˜ be๎˜ used๎˜for๎˜ a๎˜ long๎˜ period๎˜ of๎˜ time,๎˜ place๎˜ it๎˜ in๎˜ storage๎˜ after๎˜
removing๎˜the๎˜batteries.
โ—
๎˜Use๎˜a๎˜damp๎˜cloth๎˜ and๎˜detergent๎˜for๎˜cleaning๎˜ the๎˜instrument.๎˜๎˜Do๎˜ not๎˜use๎˜abrasives๎˜
or๎˜solvents.
โ—
Keep๎˜your๎˜fingers๎˜and๎˜hands๎˜behind๎˜the๎˜protective๎˜fingerguard๎˜during๎˜measurement.
Measurement Category:
๎˜๎˜๎˜๎˜To๎˜ ensure๎˜ safe๎˜ operation๎˜ of๎˜ measuring๎˜ instruments,๎˜ IEC๎˜ 61010๎˜ establishes๎˜ safety๎˜
standards๎˜for๎˜various๎˜electrical๎˜environments,๎˜categorized๎˜as๎˜O๎˜to๎˜CAT๎˜IV,๎˜and๎˜called๎˜
measurement๎˜ categories.๎˜ Higher-numbered๎˜ categories๎˜ correspond๎˜ to๎˜ electrical๎˜
environments๎˜ with๎˜ greater๎˜ momentary๎˜ energy,๎˜ so๎˜ a๎˜ measuring๎˜ instrument๎˜ designed๎˜
for๎˜ CAT๎˜ III๎˜ environments๎˜ can๎˜ endure๎˜ greater๎˜ momentary๎˜ energy๎˜ than๎˜ one๎˜ designed๎˜
for๎˜CAT๎˜II.
๎˜๎˜๎˜O๎˜ :๎˜๎˜Circuits๎˜which๎˜are๎˜not๎˜directly๎˜connected๎˜to๎˜the๎˜mains๎˜power๎˜supply.๎˜
๎˜๎˜๎˜CAT๎˜II๎˜ :๎˜๎˜Electrical๎˜circuits๎˜ of๎˜equipment๎˜connected๎˜ to๎˜an๎˜AC๎˜electrical๎˜ outlet๎˜ by๎˜a๎˜
power๎˜cord.
๎˜๎˜๎˜CAT๎˜III๎˜ :๎˜๎˜Primary๎˜ electrical๎˜ circuits๎˜ of๎˜ the๎˜ equipment๎˜ connected๎˜ directly๎˜ to๎˜ the๎˜
distribution๎˜panel,๎˜and๎˜feeders๎˜from๎˜the๎˜distribution๎˜panel๎˜to๎˜outlets.
๎˜๎˜๎˜CAT๎˜IV๎˜ :๎˜๎˜The๎˜circuit๎˜from๎˜the๎˜service๎˜drop๎˜to๎˜the๎˜service๎˜entrance,๎˜and๎˜to๎˜the๎˜power๎˜
meter๎˜and๎˜primary๎˜over-current๎˜protection๎˜device๎˜(distribution๎˜panel).
๏ผ’๏ผŽFEATURES
โ—
๎˜Permits๎˜ AC/DC๎˜ current๎˜ measurement๎˜ up๎˜ to๎˜ 60A๎˜ using๎˜ a๎˜ clamp๎˜ sensor๎˜ that๎˜ comes๎˜๎˜
standard๎˜with๎˜the๎˜instrument
โ—
Clamp๎˜sensor๎˜for๎˜ease๎˜of๎˜use๎˜in๎˜crowded๎˜cable๎˜areas๎˜and๎˜other๎˜tight๎˜places
โ—
๎˜Permits๎˜current๎˜measurement๎˜with๎˜an๎˜open๎˜current-clamp๎˜sensor๎˜that๎˜does๎˜not๎˜require๎˜
opening๎˜and๎˜closing๎˜operations๎˜by๎˜the๎˜user
โ—
Auto-power-save๎˜function
โ—
Buzzer๎˜for๎˜easy๎˜continuity๎˜checking
โ—
Data๎˜hold๎˜function๎˜to๎˜freeze๎˜the๎˜readings
โ—
LCD๎˜with๎˜a๎˜3400๎˜count๎˜full๎˜scale๎˜bar๎˜graph
โ—
Shock๎˜absorbing๎˜holster๎˜for๎˜ease๎˜of๎˜storage
โ—
๎˜Designed๎˜ to๎˜ international๎˜ safety๎˜ standard๎˜ IEC61010-1:๎˜ measurement๎˜ category๎˜
CAT๎˜
โ…ข
,๎˜300V๎˜and๎˜pollution๎˜degree๎˜2.
O: Device which is
not directly
connected to the
mains power supply
๏ผ“๏ผŽSPECIFICATIONS
โ—
Measuring๎˜Ranges๎˜and๎˜Accuracy๎˜(at๎˜23
โ„ƒยฑ
5
โ„ƒ
,๎˜relative๎˜humidity75%๎˜or๎˜less)
โ€ป
Electromagnetic
โ€ƒ
RF๎˜field๎˜๎˜
โ‰ฆ
๎˜1๎˜V/m
๎˜ compatibility
โ€ƒโ€ƒ
๎˜๎˜๎˜
ACV/DCV/OHMS/FREQUENCY๎˜total๎˜accuracy๎˜=๎˜specified๎˜accuracy
๎˜ (IEC๎˜61000-4-3)๎˜๎˜๎˜๎˜
ACA/DCA
โ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒ
๎˜
โ€ƒโ€ƒ
๎˜ total๎˜accuracy๎˜=๎˜specified๎˜accuracy+5dgt
โ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒ
๎˜
โ€ƒ
๎˜RF๎˜ transmitters๎˜ such๎˜ as๎˜ mobile๎˜ telephones๎˜ may๎˜ not๎˜ be๎˜ used๎˜ in๎˜ close๎˜
proximity.
โ—
Safety๎˜Standard๎˜ IEC๎˜61010-1
๎˜ ๎˜ ๎˜ measurement๎˜CAT๎˜
โ…ข
,๎˜300V,๎˜pollution๎˜degree๎˜2
๎˜ ๎˜ ๎˜ measurement๎˜CAT๎˜
โ…ก
,๎˜600V,๎˜pollution๎˜degree๎˜2
๎˜ ๎˜ ๎˜ IEC๎˜61010-031
๎˜ ๎˜ ๎˜ IEC๎˜61010-2-032,๎˜IEC๎˜61010-2-033
๎˜ ๎˜ ๎˜ IEC๎˜61326-1๎˜(EMC),๎˜EN๎˜50581๎˜(RoHS)
โ—
Operating๎˜System๎˜ Dual๎˜integration
โ—
Display๎˜ ๎˜ ๎˜Liquid๎˜ crystal๎˜ display๎˜ with๎˜ maximum๎˜ reading๎˜ of๎˜ 3399๎˜ as๎˜
well๎˜as๎˜units๎˜and๎˜annunciators
๎˜ ๎˜ ๎˜ Bar๎˜graph๎˜with๎˜maximum๎˜points๎˜of๎˜33
โ—
Over๎˜Input๎˜Indication๎˜ "OL"๎˜on๎˜the๎˜LCD๎˜(
ฮฉ
๎˜ranges๎˜only)
โ—
Auto-ranging๎˜Operation๎˜ ๎˜Shifts๎˜ to๎˜the๎˜ next๎˜higher๎˜ range๎˜ when๎˜bar๎˜ graph๎˜increases๎˜
to๎˜33๎˜points
๎˜ ๎˜ ๎˜ ๎˜Shifts๎˜ to๎˜the๎˜ next๎˜ lower๎˜range๎˜ when๎˜ bar๎˜graph๎˜ decreases๎˜
to๎˜3๎˜points
โ—
Sample๎˜Rate๎˜๎˜Numeric๎˜reading:๎˜about๎˜400ms,๎˜
๎˜ ๎˜ ๎˜ bar๎˜graph:๎˜about๎˜20ms
MODEL
2000A
2001A
Range
๎˜60A
100A
AC๎˜Current๎˜
โ€ƒ
๎˜A
โ€ƒ
๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜
DC๎˜Current๎˜
โ€ƒ
๎˜A๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜
AC๎˜Voltage
โ€ƒ
๎˜V
โ€ƒ
Input๎˜impedance:๎˜10M
ฮฉ
DC๎˜Voltage
โ€ƒ
๎˜V๎˜๎˜Input๎˜impedance:๎˜10M
ฮฉ
Measuring๎˜Range
0-60.0A
0-100.0A
Accuracy
๎˜
ยฑ
2.0%rdg
ยฑ
5dgt(50/60Hz)
๎˜
ยฑ
2.0%rdg
ยฑ
5dgt(50/60Hz)
MODEL
2000A
2001A
Range
๎˜60A
100A
Measuring๎˜Range
0-
ยฑ
60.0A
0-
ยฑ
100.0A
Accuracy
ยฑ
2.0
๏ผ…
rdg
ยฑ
5dgt
ยฑ
2.0
๏ผ…
rdg
ยฑ
5dgt
Range
๎˜3.4V
๎˜34V
๎˜340V
๎˜600V
Measuring๎˜Range
๎˜0-600V
(Auto-ranging)
Accuracy
ยฑ
1.5%rdg
ยฑ
5dgt(50-400Hz)
Range
๎˜340mV
๎˜3.4V
๎˜34V
๎˜340V
๎˜600V
Measuring๎˜Range
0-
ยฑ
600V
(Auto-ranging)
Accuracy
ยฑ
1.5%rdg
ยฑ
4dgt
Resistance๎˜
ฮฉ๏ผ
๎˜
Range
๎˜340
ฮฉ
๎˜3.4k
ฮฉ
๎˜34k
ฮฉ
๎˜340k
ฮฉ
๎˜3.4M
ฮฉ
๎˜34M
ฮฉ
Measuring๎˜Range
0-33.99M
ฮฉ
๎˜(Auto-ranging)
Accuracy
ยฑ
1.0%rdg
ยฑ
3dgt
Buzzer๎˜beeps๎˜below๎˜30
ยฑ
10
ฮฉ
๏ผˆ
Continuity๎˜buzzer๎˜works๎˜on๎˜340
ฮฉ
๎˜range๎˜
only
๏ผ‰
ยฑ
5%rdg
ยฑ
5dgt
ยฑ
15%rdg
ยฑ
5dgt
Frequency
โ€ƒ
Hz๎˜
Range
Current
Voltage
Measuring๎˜Range
0-3.399kHz
3.4kHz-10kHz
๎˜(Auto-ranging)
0-3.399kHz
3.4kHz-33.99kHz
34kHz-300kHz
๎˜(Auto-ranging)
Accuracy
ยฑ
0.1%rdg
ยฑ
1dgt
ยฑ
0.1%rdg
ยฑ
1dgt
โ—
Location๎˜for๎˜use๎˜ ๎˜Indoor๎˜use,๎˜Altitude๎˜up๎˜to๎˜2000m
โ—
Accuracy-insured๎˜ 23
โ„ƒยฑ
5
โ„ƒ
,๎˜relative๎˜humidity๎˜75%๎˜or๎˜less๎˜
โ€ƒ
Temperature๎˜and๎˜ (without๎˜condensation)
โ€ƒ
Humidity๎˜Ranges
โ—
Operating๎˜Temperature๎˜ 0-40
โ„ƒ
,๎˜relative๎˜humidity๎˜85%๎˜or๎˜less๎˜
โ€ƒ
and๎˜Humidity๎˜Range๎˜๎˜ (without๎˜condensation)
โ€ƒโ€ƒโ€ƒ
โ—
Storage๎˜Temperature๎˜ -20-60
โ„ƒ
,๎˜relative๎˜humidity๎˜85%๎˜or๎˜less
โ€ƒ
and๎˜Humidity๎˜Range๎˜๎˜ ๎˜(without๎˜condensation)
โ—
Source๎˜ ๎˜ Two๎˜1.5VDC๎˜R03๎˜(UM-4)๎˜batteries
โ—
Current๎˜Consumption๎˜ Approx.๎˜10mA
โ—
Power-save๎˜Function๎˜ ๎˜Shifts๎˜ to๎˜the๎˜power-save๎˜ state๎˜about๎˜ 10๎˜minutes๎˜after๎˜ the๎˜
last๎˜switch๎˜operation
๎˜ ๎˜ ๎˜ ๎˜(current๎˜consumption:๎˜approx.๎˜10
ฮผ
A)
โ€ƒโ€ƒโ€ƒ
โ—
Overload๎˜Protection๎˜ AC/DC๎˜current๎˜ranges:๎˜๎˜MODEL2000A๎˜ AC/DC๎˜ 72A๎˜ for๎˜
10๎˜seconds
โ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒ
๎˜ ๎˜AC/DC๎˜current๎˜ranges:๎˜๎˜MODEL2001A๎˜ AC/DC๎˜
120
A๎˜ for๎˜
10๎˜seconds
โ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒ
๎˜ ๎˜AC/DC๎˜voltage๎˜ranges:๎˜AC/DC๎˜720V๎˜for๎˜10๎˜seconds
๎˜ ๎˜ ๎˜ Resistance๎˜ranges:๎˜AC/DC๎˜720V๎˜for๎˜10๎˜seconds
๎˜ ๎˜ ๎˜ Frequency๎˜ranges:๎˜AC/DC๎˜720V๎˜for๎˜10๎˜seconds
โ—
Withstand๎˜Voltage๎˜ ๎˜AC3470V๎˜ for๎˜ 5๎˜ sec.๎˜ between๎˜ electrical๎˜ circuit๎˜ and๎˜
housing๎˜case
โ—
Insulation๎˜Resistance๎˜ ๎˜10M
ฮฉ
๎˜or๎˜greater๎˜at๎˜1000V๎˜between๎˜electrical๎˜circuit๎˜and๎˜
housing๎˜case
โ—
Conductor๎˜Size๎˜ MODEL2000A๎˜Approx.๎˜
โ€ƒ
6mm๎˜diameter๎˜max.
โ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒ
๎˜ ๎˜MODEL2001A๎˜Approx.๎˜10mm๎˜diameter๎˜max.๎˜
โ—
Dimensions๎˜ ๎˜ MODEL2000A๎˜128(L)
ร—
87(W)
ร—
24(D)mm
โ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒ
๎˜ ๎˜MODEL2001A๎˜128(L)
ร—
92(W)
ร—
27(D)mm๎˜
โ—
Weight๎˜ ๎˜ MODEL2000A๎˜Approx.๎˜210g
โ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒโ€ƒ
๎˜ ๎˜MODEL2001A๎˜Approx.๎˜220g
โ—
Accessories๎˜๎˜ Two๎˜R03๎˜(UM-4)๎˜batteries
๎˜ ๎˜ ๎˜ Instruction๎˜Manual
๏ผ”๏ผŽINSTRUMENT LAYOUT
Data Hold Button
MODEL2001 MODEL2000
Range Hold Button
Digital Multimeter
Function Selector Switch
Holster
Test Lead
LCD Display
AC/DC Clamp Sensor
Barrier Protective ๏ฌngerguard
DCA
Zero Adjust
Knob
๏ผ•๏ผŽPREPARATIONS FOR MEASUREMENT
๏ผˆ
1
๏ผ‰
Checking๎˜battery๎˜voltage
Set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜any๎˜position๎˜other๎˜than๎˜the๎˜OFF๎˜position.๎˜
๎˜If๎˜the๎˜marks๎˜on๎˜the๎˜ display๎˜is๎˜clearly๎˜legible๎˜without๎˜ symbol๎˜
"BATT"
๎˜showing,๎˜battery๎˜
voltage๎˜ is๎˜ OK.๎˜ If๎˜ the๎˜ display๎˜ blanks๎˜ or๎˜
"BATT"
๎˜ is๎˜ indicated,๎˜ replace๎˜ the๎˜ batteries๎˜
according๎˜to๎˜section๎˜
8: Battery Replacement
.
NOTE
When๎˜the๎˜instrument๎˜is๎˜left๎˜powered๎˜on,๎˜the๎˜auto-power-save๎˜function๎˜automatically๎˜
shut๎˜the๎˜power๎˜off;๎˜The๎˜display๎˜blanks๎˜even๎˜if๎˜the๎˜Function๎˜Selector๎˜Switch๎˜is๎˜set๎˜to๎˜
a๎˜ position๎˜ other๎˜than๎˜ the๎˜ OFF๎˜ position๎˜ in๎˜ this๎˜state.๎˜ ๎˜ To๎˜ power๎˜ on๎˜ the๎˜instrument,๎˜
turn๎˜the๎˜Function๎˜Selector๎˜Switch๎˜or๎˜press๎˜the๎˜Data๎˜Hold๎˜Button.๎˜๎˜If๎˜the๎˜display๎˜still๎˜
blanks,๎˜the๎˜batteries๎˜are๎˜exhausted.๎˜๎˜Replace๎˜the๎˜batteries.
๏ผˆ
2
๏ผ‰
Make๎˜sure๎˜that๎˜the๎˜Function๎˜Selector๎˜Switch๎˜is๎˜set๎˜to๎˜the๎˜appropriate๎˜range.
๎˜
Also๎˜ make๎˜ sure๎˜ that๎˜ data๎˜ hold๎˜ function๎˜ is๎˜ not๎˜ enabled.๎˜ ๎˜ If๎˜ inappropriate๎˜ range๎˜ is๎˜
selected,๎˜desired๎˜measurement๎˜cannot๎˜be๎˜made.
๏ผˆ
3
๏ผ‰
Install๎˜Test๎˜Lead๎˜to๎˜the๎˜Holster๎˜on๎˜the๎˜side๎˜of๎˜body
๎˜
It๎˜is๎˜ possible๎˜to๎˜ measure๎˜with๎˜seeing๎˜ the๎˜LCD๎˜ Display๎˜keep๎˜
Test๎˜Lead๎˜installing๎˜to๎˜the๎˜Holster.
AC๏ผDC
Battery Voltage Warning
Auto Range
Data Hold
Unit
Bar Graph
Buzzer
Manual
Range
Wind the lead around the folder.
Test Leads
AC/DC Clamp Sensor
๏ผ–๏ผŽHOW TO MAKE MEASUREMENT
6-1 Current
Measurement
DANGER
โ—
๎˜In๎˜order๎˜to๎˜avoid๎˜possible๎˜shock๎˜hazard,๎˜never๎˜make๎˜measurement๎˜on๎˜circuits๎˜with๎˜a๎˜
maximum๎˜ voltage๎˜ difference๎˜ of๎˜ 600VAC/DC๎˜ or๎˜ greater๎˜ between๎˜ conductors๎˜
(300VAC/DC๎˜or๎˜greater๎˜between๎˜a๎˜conductor๎˜and๎˜ground).๎˜
โ—
๎˜Do๎˜ not๎˜make๎˜ measurement๎˜with๎˜ the๎˜test๎˜ leads๎˜connected๎˜ to๎˜ the๎˜circuit๎˜ under๎˜test.๎˜
Never๎˜make๎˜measurement๎˜with๎˜the๎˜battery๎˜compartment๎˜cover๎˜removed.
โ—
Keep๎˜your๎˜fingers๎˜and๎˜hands๎˜behind๎˜the๎˜barrier๎˜during๎˜measurement.
โ€ƒ CAUTION
โ—
๎˜When๎˜handling๎˜the๎˜clamp๎˜sensor,๎˜exercise๎˜caution๎˜not๎˜to๎˜apply๎˜excessive๎˜shocks๎˜or๎˜
vibration๎˜to๎˜the๎˜sensor.๎˜
โ—
๎˜
M
aximum๎˜ measurable๎˜ conductor๎˜ size๎˜ is๎˜ MODEL2000A๎˜ 6mm๎˜ /๎˜ MODEL2001A๎˜
10mm๎˜in๎˜diameter.
โ€ƒ
6-1-1๎˜DC๎˜Current๎˜Measurement
(1)The๎˜Function๎˜Selector๎˜Swith๎˜to๎˜the๎˜"
โ€ƒ
๎˜A"๎˜position.
โ€ƒ
("DC"๎˜and๎˜"AUTO"๎˜marks๎˜are๎˜shown๎˜on๎˜the๎˜top๎˜of๎˜the๎˜display.)
(2)๎˜Turn๎˜the๎˜0(Zero)๎˜ADJ๎˜knob๎˜to๎˜set๎˜the๎˜reading๎˜of๎˜the๎˜multimeter๎˜to๎˜zero.๎˜(If๎˜this๎˜zero๎˜
adjustment๎˜is๎˜made๎˜incorrectly,๎˜measurement๎˜errors๎˜will๎˜result.)๎˜
(3)๎˜๎˜Adjust๎˜one๎˜of๎˜the๎˜conductors๎˜to๎˜the๎˜center๎˜of๎˜the๎˜clamp๎˜sensor's๎˜arrow.๎˜
โ€ƒ
๎˜(๎˜ When๎˜ the๎˜ position๎˜ of๎˜ the๎˜ conductor๎˜ is๎˜ not๎˜ at๎˜ the๎˜ center๎˜ of๎˜ the๎˜ arrow,๎˜ the๎˜ error๎˜
occurs.)
๎˜๎˜๎˜๎˜๎˜Measured๎˜value๎˜is๎˜shown๎˜on๎˜the๎˜display.
Note:๎˜๎˜When๎˜current๎˜flows๎˜from๎˜the๎˜upside๎˜to๎˜the๎˜underside๎˜of๎˜the๎˜instrument,๎˜the๎˜polarity๎˜
of๎˜the๎˜reading๎˜is๎˜positive๎˜(+).๎˜๎˜Otherwise,๎˜the๎˜polarity๎˜of๎˜the๎˜reading๎˜is๎˜negative๎˜(-).๎˜
โ€ƒ
6-1-2๎˜AC๎˜Current๎˜Measurement
(1)Set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜"
โ€ƒ
๎˜A."
โ€ƒ
("AC"๎˜and๎˜"AUTO"๎˜marks๎˜are๎˜shown๎˜on๎˜the๎˜top๎˜of๎˜the๎˜LCD.)
(2)๎˜Adjust๎˜one๎˜of๎˜the๎˜conductors๎˜to๎˜the๎˜center๎˜of๎˜the๎˜clamp๎˜sensor's๎˜arrow.
โ€ƒ
๎˜๎˜(๎˜ When๎˜ the๎˜ position๎˜ of๎˜ the๎˜ conductor๎˜ is๎˜ not๎˜ at๎˜ the๎˜ center๎˜ of๎˜ the๎˜ arrow,๎˜ the๎˜ error๎˜
occurs.)
๎˜๎˜๎˜๎˜๎˜Measured๎˜value๎˜is๎˜shown๎˜on๎˜the๎˜display.
Note:๎˜๎˜Unlike๎˜ DC๎˜ current๎˜measurement,๎˜ zero๎˜ adjustment๎˜ is๎˜not๎˜ necessary.๎˜ ๎˜ There๎˜ is๎˜not๎˜
polarity๎˜indication๎˜either.
6-2 Voltage Measurement
DANGER
โ—
๎˜In๎˜order๎˜to๎˜avoid๎˜possible๎˜shock๎˜hazard,๎˜never๎˜make๎˜measurement๎˜on๎˜circuits๎˜with๎˜a๎˜
maximum๎˜ voltage๎˜ difference๎˜ of๎˜ 600VAC/DC๎˜ or๎˜ greater๎˜ between๎˜ conductors๎˜
(300VAC/DC๎˜or๎˜greater๎˜between๎˜a๎˜conductor๎˜and๎˜ground).๎˜
โ—
๎˜Do๎˜not๎˜make๎˜measurement๎˜with๎˜the๎˜battery๎˜compartment๎˜cover๎˜removed.
โ—
Keep๎˜your๎˜fingers๎˜and๎˜hands๎˜behind๎˜the๎˜protective๎˜fingerguard๎˜during๎˜measurement.
โ€ƒ
6-2-1๎˜DC๎˜Voltage๎˜Measurement
(1)Set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜"
โ€ƒ
๎˜V."
โ€ƒ
๎˜
๏ผˆ
"DC"๎˜and๎˜"AUTO"๎˜marks๎˜are๎˜shown๎˜on๎˜the๎˜top๎˜of๎˜the๎˜LCD.
๏ผ‰
(2)๎˜Connect๎˜the๎˜ red๎˜test๎˜ lead๎˜to๎˜ the๎˜positive๎˜ (+)๎˜side๎˜of๎˜ the๎˜circuit๎˜ under๎˜test๎˜ and๎˜the๎˜
black๎˜ test๎˜lead๎˜ to๎˜ the๎˜negative๎˜ (-)๎˜ side.๎˜๎˜ Measured๎˜ voltage๎˜ value๎˜is๎˜ shown๎˜ on๎˜the๎˜
display.
โ€ƒ
๎˜When๎˜the๎˜connection๎˜is๎˜reversed,๎˜"-"๎˜is๎˜shown๎˜on๎˜the๎˜display.
Conductor
MODEL2000A MODEL2001A
Adjust a
conductor to
the center of
the arrow.
Correct Wrong
โ€ƒ
6-2-2๎˜AC๎˜Voltage๎˜Measurement
(1)Set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜"
โ€ƒ
๎˜V."
โ€ƒ
๎˜
๏ผˆ
"AC"๎˜and๎˜"AUTO"๎˜marks๎˜are๎˜shown๎˜on๎˜the๎˜LCD.
๏ผ‰
(2)๎˜Connect๎˜the๎˜test๎˜leads๎˜to๎˜the๎˜circuit๎˜under๎˜test.
โ€ƒ
๎˜Measured๎˜voltage๎˜value๎˜is๎˜shown๎˜on๎˜the๎˜display.
6-3 Resistance Measurement
DANGER
โ—
๎˜Never๎˜make๎˜measurement๎˜on๎˜circuits๎˜that๎˜are๎˜live.๎˜
โ—
๎˜Never๎˜make๎˜measurement๎˜with๎˜the๎˜battery๎˜compartment๎˜cover๎˜removed.๎˜
โ—
Keep๎˜your๎˜fingers๎˜and๎˜hands๎˜behind๎˜the๎˜protective๎˜fingerguard๎˜during๎˜measurement.
(1)Set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜"
ฮฉ๏ผ
๎˜
โ€ƒ
."
(2)๎˜Check๎˜ that๎˜the๎˜ display๎˜shows๎˜ over-range.๎˜Short๎˜ the๎˜ test๎˜leads๎˜ and๎˜check๎˜ that๎˜the๎˜
buzzer๎˜beeps๎˜and๎˜the๎˜display๎˜reads๎˜zero.
(3)๎˜Connect๎˜ the๎˜ test๎˜ leads๎˜ to๎˜ the๎˜ circuit๎˜ under๎˜ test.๎˜ Measured๎˜ resistance๎˜ value๎˜ is๎˜
shown๎˜on๎˜the๎˜display.๎˜ ๎˜When๎˜the๎˜ measured๎˜value๎˜ is๎˜below๎˜about๎˜ 30
ฮฉ
,๎˜the๎˜buzzer๎˜
beeps.
Note:๎˜๎˜When๎˜ the๎˜ test๎˜ leads๎˜ are๎˜ shorted,๎˜ the๎˜ display๎˜ may๎˜ read๎˜ a๎˜ small๎˜ resistance๎˜ value.๎˜๎˜
This๎˜is๎˜the๎˜resistance๎˜of๎˜the๎˜test๎˜leads.๎˜๎˜
๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜If๎˜there๎˜is๎˜an๎˜open๎˜in๎˜either๎˜of๎˜the๎˜test๎˜leads,๎˜"OL"๎˜is๎˜shown๎˜on๎˜the๎˜display.๎˜
๎˜๎˜๎˜๎˜๎˜
โ€ƒ
๎˜On๎˜the๎˜340
ฮฉ
๎˜range,๎˜"
โ€ƒ
๎˜"๎˜is๎˜shown๎˜on๎˜the๎˜left๎˜side๎˜of๎˜the๎˜LCD.
6-4 Frequency Measurement
DANGER
โ—
๎˜๎˜In๎˜order๎˜to๎˜avoid๎˜possible๎˜shock๎˜hazard,๎˜never๎˜make๎˜measurement๎˜on๎˜circuits๎˜with๎˜a๎˜
maximum๎˜ voltage๎˜ difference๎˜ of๎˜ 600VAC/DC๎˜ or๎˜ greater๎˜ between๎˜ conductors๎˜
(300VAC/DC๎˜or๎˜greater๎˜between๎˜a๎˜conductor๎˜and๎˜ground).๎˜
โ—
๎˜๎˜Do๎˜ not๎˜make๎˜ measurement๎˜with๎˜ the๎˜test๎˜ leads๎˜ connected๎˜to๎˜ the๎˜circuit๎˜ under๎˜test.๎˜
Never๎˜make๎˜measurement๎˜with๎˜the๎˜battery๎˜compartment๎˜cover๎˜removed.
โ—
๎˜๎˜Do๎˜not๎˜make๎˜current๎˜measurement๎˜with๎˜the๎˜test๎˜leads๎˜connected๎˜to๎˜the๎˜circuit๎˜under๎˜
test.
โ—
Keep๎˜your๎˜fingers๎˜and๎˜hands๎˜behind๎˜the๎˜protective๎˜fingerguard๎˜during๎˜measurement.
(1)Set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜"Hz."
(2)๎˜Measuring๎˜frequency๎˜of๎˜current:
โ€ƒโ€ƒ
๎˜Adjust๎˜one๎˜of๎˜the๎˜conductors๎˜to๎˜the๎˜center๎˜of๎˜the๎˜clamp๎˜sensor's๎˜arrow.๎˜Measured๎˜
value๎˜is๎˜shown๎˜on๎˜the๎˜display.
โ€ƒโ€ƒ
Measuring๎˜frequency๎˜of๎˜voltage:
โ€ƒโ€ƒ
๎˜Connect๎˜the๎˜test๎˜leads๎˜to๎˜the๎˜circuit๎˜under๎˜test.๎˜๎˜Measured๎˜frequency๎˜is๎˜shown๎˜on๎˜
the๎˜display.
Note:๎˜๎˜Measuring๎˜range๎˜ of๎˜current๎˜ frequency๎˜is๎˜0-10kHz๎˜ with๎˜minimum๎˜ measurable๎˜input๎˜
of๎˜MODEL2000A๎˜15A
๏ผˆ
Typ
๏ผ‰
/MODEL2001A๎˜25A
๏ผˆ
Typ
๏ผ‰
.๎˜
๎˜๎˜๎˜๎˜๎˜
โ€ƒ
๎˜Measuring๎˜range๎˜of๎˜voltage๎˜frequency๎˜is๎˜0-300kHz๎˜with๎˜minimum๎˜measurable๎˜input๎˜
of๎˜30V
๏ผˆ
Typ
๏ผ‰
.
๎˜๎˜๎˜
โ€ƒ
๎˜When๎˜measuring๎˜ frequency,๎˜do๎˜not๎˜ attach๎˜the๎˜ clamp๎˜sensor๎˜ and๎˜the๎˜test๎˜ leads๎˜to๎˜
the๎˜circuit๎˜under๎˜test๎˜simultaneously.
Prohibition
๏ผ—๏ผŽOTHER FUNCTIONS
7-1๎˜๎˜Auto-Power-Save๎˜Function๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜๎˜
NOTE
A๎˜small๎˜amount๎˜ of๎˜current๎˜is๎˜ consumed๎˜even๎˜ in๎˜the๎˜ power-save๎˜state.๎˜๎˜ Make๎˜sure๎˜
to๎˜set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜the๎˜OFF๎˜position๎˜when๎˜the๎˜instrument๎˜is๎˜not๎˜
used.
This๎˜ function๎˜ helps๎˜ to๎˜ avoid๎˜ unwanted๎˜ exhaustion๎˜ of๎˜ the๎˜ batteries๎˜ because๎˜ of๎˜
leaving๎˜ the๎˜ instrument๎˜ powered๎˜ on๎˜ and๎˜ extend๎˜ battery๎˜ life.๎˜ ๎˜ The๎˜ instrument๎˜
automatically๎˜ shifts๎˜ to๎˜ the๎˜ power-save๎˜ state๎˜ about๎˜ 10๎˜ minutes๎˜ after๎˜ the๎˜ last๎˜
Function๎˜Selector๎˜Switch๎˜or๎˜other๎˜switch๎˜operation.๎˜๎˜
To๎˜ return๎˜to๎˜ the๎˜ normal๎˜ state:๎˜ ๎˜Turn๎˜ the๎˜ Function๎˜ Selector๎˜Switch๎˜ or๎˜ press๎˜ the๎˜
Data๎˜ Hold๎˜ Button๎˜ twice๎˜ to๎˜ exit๎˜ the๎˜ power-save๎˜ state๎˜ and๎˜ enable๎˜ measurement๎˜
functions.
7-2๎˜Data๎˜Hold๎˜Function
This๎˜ is๎˜ a๎˜ function๎˜ to๎˜ freeze๎˜ a๎˜ measured๎˜ value๎˜ on๎˜ the๎˜ display.๎˜ ๎˜ Press๎˜ the๎˜ Data๎˜
Hold๎˜Button๎˜once๎˜to๎˜hold๎˜the๎˜current๎˜reading.๎˜๎˜In๎˜this๎˜data๎˜hold๎˜state,๎˜the๎˜reading๎˜
is๎˜held๎˜even๎˜if๎˜input๎˜varies.๎˜๎˜"H"๎˜ and๎˜"
โ€ƒ
๎˜"๎˜marks๎˜are๎˜shown๎˜on๎˜the๎˜LCD๎˜ instead๎˜
of๎˜"AUTO"๎˜mark.๎˜๎˜
To๎˜exit๎˜the๎˜data๎˜hold๎˜state,๎˜press๎˜the๎˜Data๎˜Hold๎˜Button๎˜again.
7-3๎˜Range๎˜Hold๎˜Function
The๎˜ instrument๎˜ defaults๎˜ to๎˜ auto-ranging๎˜ ("AUTO"๎˜ is๎˜ shown๎˜ on๎˜ the๎˜ LCD).๎˜๎˜
Pressing๎˜ the๎˜Range๎˜ Hold๎˜Button๎˜ enables๎˜ manual๎˜selection๎˜ among๎˜measurement๎˜
ranges
๏ผˆ
"
โ€ƒ
๎˜"๎˜mark๎˜is๎˜shown๎˜on๎˜the๎˜LCD๎˜instead๎˜of๎˜"AUTO"๎˜mark
๏ผ‰
Press๎˜the๎˜Range๎˜Hold๎˜Button๎˜to๎˜select๎˜a๎˜higher๎˜range.๎˜
โ€ƒ
To๎˜ switch๎˜ from๎˜ manual๎˜ range๎˜ selection๎˜ to๎˜ auto-ranging,๎˜ press๎˜ down๎˜ the๎˜ Range๎˜
Hold๎˜ Button๎˜ for๎˜ about๎˜ one๎˜ seconds,๎˜ or๎˜ turn๎˜ the๎˜ Function๎˜ Selector๎˜ Switch๎˜ to๎˜
another๎˜position๎˜before๎˜setting๎˜it๎˜back๎˜to๎˜the๎˜current๎˜range.๎˜
๏ผ˜๏ผŽBATTERY REPLACEMENT
WARNING
โ—
๎˜In๎˜ order๎˜ to๎˜avoid๎˜ possible๎˜ shock๎˜ hazard,๎˜always๎˜ disconnect๎˜ the๎˜ test๎˜leads๎˜ from๎˜
the๎˜circuit๎˜ under๎˜test๎˜ and๎˜set๎˜the๎˜ Function๎˜Selector๎˜ Switch๎˜to๎˜ the๎˜OFF๎˜position๎˜
before๎˜trying๎˜to๎˜replace๎˜the๎˜batteries.
โ€ƒ CAUTION
โ—
๎˜Do๎˜not๎˜mix๎˜new๎˜and๎˜old๎˜batteries.๎˜
โ—
๎˜Install๎˜ batteries๎˜ in๎˜ the๎˜ orientation๎˜ as๎˜ shown๎˜ inside๎˜ the๎˜ battery๎˜ compartment,๎˜
observing๎˜correct๎˜polarity.
When๎˜the๎˜battery๎˜voltage๎˜warning๎˜mark๎˜"BATT"๎˜is๎˜shown๎˜on๎˜the๎˜top๎˜left๎˜corner๎˜of๎˜the๎˜
LCD,๎˜ replace๎˜ the๎˜ batteries.๎˜ ๎˜ Note๎˜ that๎˜ the๎˜ display๎˜ blanks๎˜ and๎˜ "BATT"๎˜ mark๎˜ is๎˜ not๎˜
shown๎˜if๎˜the๎˜batteries๎˜are๎˜completely๎˜exhausted.
โ€ƒ
(1)๎˜Set๎˜the๎˜Function๎˜Selector๎˜Switch๎˜to๎˜"OFF."
โ€ƒ
(2)๎˜Remove๎˜the๎˜instrument๎˜from๎˜the๎˜holster.
โ€ƒ
(3)๎˜Loosen๎˜ the๎˜ battery-compartment-cover-fixing๎˜ screw๎˜ on๎˜ the๎˜ lower๎˜ back๎˜ of๎˜ the๎˜
instrument.๎˜
โ€ƒ
(4)๎˜Replace๎˜the๎˜batteries๎˜with๎˜two๎˜new๎˜R03๎˜(UM-4)๎˜1.5V๎˜batteries.
โ€ƒ
(5)๎˜Put๎˜the๎˜battery๎˜compartment๎˜cover๎˜back๎˜in๎˜place๎˜and๎˜tighten๎˜the๎˜screw.
Screw
Battery
Compartment
Cover
Batteries
92-2318A6-18
DISTRIBUTOR
Kyoritsu๎˜ reserves๎˜ the๎˜ rights๎˜ to๎˜ change๎˜ sp ecifications๎˜ or๎˜
designs๎˜ described๎˜ in๎˜ this๎˜ manual๎˜ without๎˜ notice๎˜ and๎˜ without๎˜
obligations.
Test๎˜ Lead๎˜ Cap
๏ผš
Test๎˜ leads๎˜ can๎˜ be๎˜ used๎˜ under๎˜ the๎˜ CAT.II๎˜ and๎˜ III๎˜ environments๎˜ by๎˜
attaching๎˜ a๎˜ Protective๎˜ cap๎˜ as๎˜ illustrated๎˜ below.๎˜ Use๎˜ of๎˜ our๎˜ Protective๎˜ cap๎˜ offers๎˜
different๎˜lengths๎˜suitable๎˜for๎˜the๎˜test๎˜environments.
Barrer
Protective๎˜fingerguard
๏ผš
๎˜It๎˜ is๎˜ a๎˜ part๎˜ providing๎˜ protection๎˜ against๎˜ electrical๎˜ shock๎˜ and๎˜
ensuring๎˜the๎˜minimum๎˜required๎˜air๎˜and๎˜creepage๎˜distances.
Protective Cap
Exposed metal part
Uncapped condition for CAT.II environment
Capped condition for CAT.III environments
This๎˜ instrument๎˜ satisfies๎˜ the๎˜ marking๎˜ requirement๎˜ defined๎˜ in๎˜ the๎˜ WEEE๎˜
Directive.๎˜ This๎˜ symbol๎˜ indicates๎˜ separate๎˜ collection๎˜ for๎˜ electrical๎˜ and๎˜
electronic๎˜equipment.
This๎˜marking๎˜means๎˜they๎˜shall๎˜be๎˜sorted๎˜out๎˜and๎˜collected๎˜as๎˜ordained๎˜in๎˜
DIRECTIVE.
This๎˜ directive๎˜ is๎˜ valid๎˜ only๎˜ in๎˜ the๎˜ EU.๎˜ When๎˜ you๎˜ remove๎˜ batteries๎˜ from๎˜
this๎˜product๎˜and๎˜dispose๎˜them,๎˜discard๎˜them๎˜in๎˜accordance๎˜with๎˜domestic๎˜
law๎˜concerning๎˜disposal.๎˜Take๎˜a๎˜right๎˜action๎˜on๎˜waste๎˜batteries,๎˜because๎˜
the๎˜collection๎˜system๎˜in๎˜the๎˜EU๎˜on๎˜waste๎˜batteries๎˜are๎˜regulated.


Product specificaties

Merk: Kyoritsu
Categorie: Multimeter
Model: KEW Mate 2000A

Heb je hulp nodig?

Als je hulp nodig hebt met Kyoritsu KEW Mate 2000A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Kyoritsu

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter