Kospel HPM2.Z-8 Handleiding
Kospel
Warmtepomp
HPM2.Z-8
Lees hieronder de 📖 handleiding in het Nederlandse voor Kospel HPM2.Z-8 (48 pagina's) in de categorie Warmtepomp. Deze handleiding was nuttig voor 48 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/48
Installation and Operating Instructions
Master copy of the Instructions
Heat Pump
HPMI2 - 8
HPMI2 - 12
HPMI2 - 16
HPMO2 - 8 HPMO2 - 12 HPMO2 - 16/23
2
This device may be used by children aged 8 years and over and
by persons with reduced physical, sensory or mental abilities
or lack of experience and knowledge, if they are supervised
or have been instructed concerning the safe use of the device
and have understood the resulting hazards. Children must not
play with the device. Cleaning and maintenance of the device
may not be carried out by children without supervision.
The HPM2.Z heat pump is a hermetically
sealed unit and it contains îž½uorinated
greenhouse gases.
WARNING
Do not use any agents to speed up the defrosting or cleaning
process other than those recommended by the Manufacturer.
Store the device in a room without any constantly operating
sources of ignition (for example: an open îž½ame, an operating
gas device or an operating electric heater). Do not puncture
or burn the device. Note that refrigerants may be odourless.
The device is to be installed, operated and stored in a room with
adequate space and cubic area (see the table).
NOTE: The Manufacturer may provide relevant examples or additional information on refrigerant’s odour.
This equipment is intended for use by qualiîž¼ed or trained users
in shops, light industry and on farms, or for use at home by
those who have no specialist knowledge.
3
EN-115B_f.1420
1. Familiarisation with the contents of this manual will enable the device to be installed and operated correctly, ensuring its
long-lasting and reliable operation.
2. The device must be installed in compliance with national installation regulations.
3. An electrical installation that is operational and carried out in accordance with PN-IEC 60364.
4. Considering its intended use, the device may only be installed and operated in closed heating systems in accordance with
EN 12828, taking into account the relevant installation, service and operating instructions.
â– Work on the refrigeration circuit must only be carried out by authorised specialists.
â– Initial commissioning is to be carried out by an Authorised Installer or a designated authorised person.
5. Unsuitable ambient conditions may cause damage to the installation and jeopardise operational safety (avoid air pollution
by halogenated alkanes contained e.g. in paints, solvents and cleaning agents, avoid constant high air humidity e.g. due to
frequent drying of laundry).
6. The installation of the device and the electrical and plumbing work must be carried out by a specialised service company
and the instructions for the assembly and use of the product must be strictly observed.
7. All installation work must be carried out with the electricity and water supply being cut off.
8. Sparks may occur due to an electrostatic discharge, which can ignite the leaking refrigerant (R32). Touch earthed objects,
e.g. heating or water pipes, to dissipate static charges before carrying out work.
9. Hot surfaces may cause burns.
10. Direct contact with the liquid and gaseous refrigerant may cause serious damage to health.
11. The electrical installation must be îž¼tted with residual current protective devices and means to ensure that the equipment
is disconnected from the power source, where the distance between the contacts of all the poles is not less than 3mm.
12. The heat pump is a surge-sensitive device and the electrical installation must therefore include surge protection devices.
13. There is a hazard of scalding in the event of an open îž½ame.
14. R32 is the refrigerant used; this is an air displacing, colourless, odourless gas that forms a îž½ammable mixture with air.
Conditions for safe and reliable operation
Description of the device
The HPM2.Z heat pump is an device designed for heating/cooling a building and heating tap water.
The unit consists of two modules:
- The outdoor HPMO2 module: a compressor heat pump.
The working principle of the unit is to capture heat from the environment and to transfer it to the heating circuit in the
building. The low-temperature heat of the air is transferred through an evaporator to the heat pump system îž¼lled with
a refrigerant, which turns into a gas as it evaporates. From the evaporator, the gas is drawn in by the compressor, which
raises its temperature during its compression and directs it to the condenser. In the condenser, heat is transferred to the
refrigerant, which îž¼lls the central heating system, and the cooled liquid îž½ows through the expansion valve and returns to the
evaporator, after which the whole process starts again. In the case of cooling, this cycle is reversed and the heat is extracted
from the building and discharged outside.
- The indoor HPMI2 module: a hydraulic module equipped with a controller for the entire system.
The working principle of the unit is based on the demand-dependent capacity control of the heat pump compressor with an
activation of the electrical auxiliary heater via the controller of the indoor module. The indoor module controller regulates
the heating output according to a pre-set heating curve. If the heat pump is not able to cover the building’s heating demand
on its own, the controller automatically activates the electrical auxiliary heater which, together with the heat pump produces
the desired heating medium temperature.
Product specificaties
Merk: | Kospel |
Categorie: | Warmtepomp |
Model: | HPM2.Z-8 |
Heb je hulp nodig?
Als je hulp nodig hebt met Kospel HPM2.Z-8 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Warmtepomp Kospel
29 November 2023
29 November 2023
29 November 2023
29 November 2023
29 November 2023
29 November 2023
Handleiding Warmtepomp
- Warmtepomp Electrolux
- Warmtepomp Bosch
- Warmtepomp Samsung
- Warmtepomp LG
- Warmtepomp AEG
- Warmtepomp ATAG
- Warmtepomp Grundig
- Warmtepomp Inventum
- Warmtepomp Junkers
- Warmtepomp Miele
- Warmtepomp Nefit
- Warmtepomp Remeha
- Warmtepomp Siemens
- Warmtepomp Vaillant
- Warmtepomp Alpha Innotec
- Warmtepomp Arcelik
- Warmtepomp Astralpool
- Warmtepomp Atlantic
- Warmtepomp AWB
- Warmtepomp Azuro
- Warmtepomp Balay
- Warmtepomp Blaupunkt
- Warmtepomp Daikin
- Warmtepomp Danfoss
- Warmtepomp De Dietrich
- Warmtepomp Dimplex
- Warmtepomp Elco
- Warmtepomp Fairland
- Warmtepomp Ferroli
- Warmtepomp Fisher And Paykel
- Warmtepomp Flojet
- Warmtepomp Fujitsu
- Warmtepomp Harmopool
- Warmtepomp Hisense
- Warmtepomp Hotpoint
- Warmtepomp Hydro-Pro
- Warmtepomp Itho-Daalderop
- Warmtepomp Maxicool
- Warmtepomp Midea
- Warmtepomp Mitsubishi
- Warmtepomp Nibe
- Warmtepomp Qlima
- Warmtepomp REMKO
- Warmtepomp Stiebel Eltron
- Warmtepomp Techneco
- Warmtepomp Thermor
- Warmtepomp Viessmann
- Warmtepomp Vivax
- Warmtepomp Westinghouse
- Warmtepomp Wita
- Warmtepomp Zodiac
- Warmtepomp Olimpia Splendid
- Warmtepomp Wilfa
- Warmtepomp Orima
- Warmtepomp Tesy
- Warmtepomp Baxi
- Warmtepomp Carrier
- Warmtepomp Armstrong
- Warmtepomp Calorex
- Warmtepomp JANDY
- Warmtepomp MRCOOL
- Warmtepomp Grundfos
- Warmtepomp Wilo
- Warmtepomp Waterco
Nieuwste handleidingen voor Warmtepomp
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
7 November 2024
7 November 2024
7 November 2024
5 November 2024