Klein Tools NCVT-2 Handleiding
Klein Tools
Meetapparatuur
NCVT-2
Lees hieronder de đ handleiding in het Nederlandse voor Klein Tools NCVT-2 (8 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 15 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/8
NON-CONTACT VOLTAGE TESTER
(NCVT-2) OwNERâS MANuAL
Fig. 1
Locking tab
LengĂŒeta de ïŹjaciĂłn
Languette de
verrouillage
Probe
Punta de prueba
Sonde
Body /Cuerpo/Corps
Cap /Tapa/Capuchon
Power button
BotĂłn de encendido
Interrupteur
Fig. 2
Gently push down on locking tab.
Empuje suavemente hacia abajo.
Appuyez doucement sur la languette de verrouillage.
AAAAAA
Fig. 4
While pushing down on tab, slide cap off body.
Mientras empuja hacia abajo sobre la lengĂŒeta, deslice la
tapa hasta separarla del cuerpo.
Tout en appuyant sur la languette, faites glisser le capuchon
pour le détacher du corps du détecteur.
Align channel tabs on cap with slots on
tester body (one on each side of tester).
Alinee las lengĂŒetas de canal ubicadas en la
tapa con las ranuras ubicadas en el cuerpo del
probador (una a cada lado del probador).
Alignez les languettes Ă proïŹlĂ©s sur le
capuchon avec les fentes du corps du dé-
tecteur (une de chaque cÎté du détecteur).
Slide cap onto body.
Deslice la tapa
sobre el cuerpo.
Faites glisser le capuchon
sur le corps du détecteur.
Align locking tab with cap.
Alinee la lengĂŒeta de ïŹjaciĂłn con la tapa.
Alignez la languette de verrouillage avec le capuchon.
Hold pocket-clip on cap close to tester body while sliding cap onto tester.
Sujete el clip para bolsillo ubicado en la tapa cerca del cuerpo del probador
mientras desliza la tapa sobre el probador.
Maintenez la pince-agrafe sur le capuchon à proximité du corps du détecteur
tout en faisant glisser le capuchon sur le détecteur.
Fig. 3
KLEIN TOOLS, INC.
Chicago, IL USA
© 2015
www.kleintools.com
139805 Rev. 01/15 B
DuAL RANGE
MANUAL DEL USUARIO DEL PROBADOR DE TENSIĂN
SIN CONTACTOS DE INTERVALO DUAL (NCVT-2)
DĂ©TECTEUR DE TENSION SANS CONTACT Ă
DOUBLE PLAGE (NCVT-2) - MODE DâEMPLOI
ENGLISH
SYMBOLS ON TESTER:
Warning. Risk of electric shock.
Risk of danger. Important information: It is important that users of this tester read,
understand, and follow all warnings, cautions, safety information, and instructions in this manual
before operating or servicing this tester. Failure to follow instructions could result in death or
serious injury.
Double Insulated.
Equipment is designed to protect against transients from the primary supply level.
(i.e. - electricity meter or overhead/ underground utility service).
OPERATING INSTRUCTIONS:
Modes of operation:
The NCVT-2 can operate as a dual range (NCVT-2 mode) or single range (NCVT-1 mode) tester. In
NCVT-2 mode, the tester will light a steady blue LED in the tip to indicate power-on and dual range
mode. In NCVT-1 mode, the tester will light a steady green LED in the tip to indicate power-on and
single range mode.
Turn unit on:
Press and hold the power button for œ second, then release. Listen for single-beep sound and
watch for a steady green or blue LED to illuminate in the tip of the tester. The tester is now
activated and is operational. Test on known live circuit to verify tester functionality. See Silent
mode for additional power-on options.
Turn unit off:
Press and hold the power button for œ second then release. Listen for a double-beep sound and
watch the green or blue LED turn off. The tester is now deactivated and is not operational.
System self-test:
The âpower onâ blue or green LED visually conïŹrms battery sufïŹciency, system integrity, and
operation/active mode. Always test on known live circuit to verify tester functionality prior to use.
Changing operation modes:
While the unit is powered on, press and hold the power button for 2 seconds. The power-on LED
will switch from blue to green or green to blue. The tester will start in whichever mode it was last
powered off in.
Checking for the presence of AC voltage:
Prior to use, test on known live circuit to verify tester functionality. Place tip of the tester near an
AC voltage and refer to the tables below for each mode:
NCVT-2 mode:
POWER-ON 12 TO 48 VOLTS AC 48 TO 1000 VOLTS AC
Audible
Single Beep Low-Pitched Pulsing Beeping Sound
High-Pitched Continuous Beeping Sound
Visual
Steady Blue LED
Blue LED Turns OFF and Red LED
Blinks (approx. 2-times per second).
Blue LED Turns OFF and Red LED
illuminates continuously.
NCVT-1 mode:
POWER-ON 12 TO 48 VOLTS AC 48 TO 1000 VOLTS AC
Audible
Single Beep No Sound
High-Pitched Continuous Beeping Sound
Visual
Steady Green LED Steady Green LED Green LED Turns OFF and Red LED
illuminates continuously.
In NCVT-2 mode, the tester will be more sensitive and will show voltage indication at a further
distance away from a high voltage source than in NCVT-1 mode. Use NCVT-1 mode in situations
where you expect the voltage source will be greater than 48V AC.
Low battery indication:
Scenario 1 â Powering on the tester: The âpower onâ LED in the tip of the tester changes from a
steady green or blue to a blinking green or blue and a series of beeping sounds is generated. The
tester then turns off. The unit is now deactivated and is not operational, the batteries require replace-
ment. To replace the tester batteries refer to the Maintenance section titled âBattery Replacement.â
Scenario 2 â Operating the tester: If the LED lights dim and the tone fades, the tester may require new
batteries. To replace the tester batteries refer to the Maintenance section titled âBattery Replacement.â
Auto Power Off:
After 4 minutes of non-use, the tester automatically powers off to conserve battery life. Listen for
a double-beep sound and watch the âpower onâ LED turn off. The tester is now deactivated and
is not operational.
Silent mode:
The tester can be operated with only visual indication of voltage. With the tester powered off, press
and hold the power button for 2 seconds then release.
MAINTENANCE:
Battery Replacement:
âąî Orient the tool/tester with the pocket-clip facing you.
âąî Gently depress the tab, Fig. 2, until you can slide the end-cap off the main body of the tester.
âąî Remove the batteries using caution to prevent damage or injury to the internal components.
âąî Replace with two 1.5V AAA or LR03 or NEDA 24A batteries.
âąî Place batteries into tester with the positive terminals facing the tip, Fig. 3.
âąî Carefully align and slide the end-cap to the body of the tester, Fig. 4. Push the cap until it is
fully seated (denoted by a clicking sound), Fig. 4.
âąî Note: Hold pocket-clip on cap close to tester body while sliding cap onto tester.
âąî Test on known live circuit to verify tester functionality.
CAT
IV
SPECIFICATIONS:
VOLTAGE RANGE: 12-1000 Volts AC
TESTER TYPE: Non-Contact Voltage Detector
UL CERTIFICATION
E321008 3TMV
FREQUENCY RANGE:
50-500Hz
STAN DARDS:
UL 61010-1 2
nd
edition, CAN/CSA C22.2 No.
61010-1-04, EN 61010-1 2
nd
edition, IEC
61010-1:2001 2
nd
edition, ISA-82.02.01
(IEC61010-1 MOD)
CAT IV RATED: 1000 V
DOUBLE INSULATED
POWER ON INDICATOR AND ILLUMINATOR:
Visual: High Intensity Green/Blue LED
POWER OFF & AUTO POWER OFF:
Visual: High Intensity Green LED Blinks
Audible: Double Beeping Sound
LOW BATTERY INDICATORS:
Visual: Green/Blue LED Blinks
Audible: Series of Beeping Sounds
VOLTAGE DETECTION INDICATORS:
12 VOLTS TO 48 VOLTS:
Visual: High Intensity Blinking Red LED
Audible: Low Pitched, Pulsing Beeping Sound
48 VOLTS TO 1000 VOLTS
Visual: High Intensity Continuously
Illuminated Red LED
Audible: High Pitched, Continuous
Beeping Sound
OPERATING CONDITIONS:
Temperature: 32° to 104° F (0° to 40° C)
Relative Humidity: <80%
Altitude: Up to 6,562 feet (2,000 meters) max.
Environment: Indoor Use
STORAGE CONDITIONS:
Temperature: 32° to 104° F (0° to 40° C)
Relative Humidity: <80%
Altitude: Up to 6,562 feet (2,000 meters) max.
Environment: Indoor
POLLUTION DEGREE: 2
BATTERIES: Two 1.5 volt AAA
or IEC LR03 or NEDA 24A
PATENTS: US D583,266 S
DISPOSAL: DO NOT THROW IN TRASH;
PLEASE RECYCLE.
CAT
IV
CAuTION:
âąî Do not attempt to repair this tester. It contains no serviceable parts.
âąî Do not expose the product to extremes in temperature or high humidity.
wARNINGS:
âąî It is important that users of this tester read, understand, and follow all warnings, cautions, safety
information, and instructions in this manual before operating or servicing this tester. Failure to
follow instructions could result in death or serious injury.
âąî Risk of electric shock and burn. Contact with live circuits could result in death or serious injury.
âąî Use caution with voltages above 30V AC as a shock hazard may exist.
âąî A blinking or steady red glow and an audible beep indicate voltage present. If no indication, voltage
could still be present.
âąî Never assume neutral or ground wires are de-energized. Neutrals in multi-wire branch circuits may be
energized when disconnected and must be retested before handling.
âąî The tester detect voltage if:WILL NOT
âąî the wire is shielded.
âąî the operator is not grounded or is otherwise isolated from an effective earth ground.
âąî the voltage is DC.
âąî The tester MAY NOT detect voltage if:
âąî the user is not holding the tester.
âąî the user is insulated from the tester with a glove or other materials.
âąî the wire is partially buried or in a grounded metal conduit.
âąî the tester is at a distance from the voltage source.
âąî the ïŹeld created by the voltage source is being blocked, dampened, or otherwise interfered with.
âąî the frequency of the voltage is not a perfect sine wave between 50 and 500Hz.
âąî the tester is outside of operation conditions (listed in SpeciïŹcations section).
âąî Operation may be affected by differences in socket design and insulation thickness and type.
âąî In bright light conditions, the LED visual indicators will be less visible.
âąî Do not use if "power on" LED is not illuminated.
âąî Do not use if tester appears damaged or if the tester is not operating properly. If in doubt, replace the tester.
âąî Do not apply more than the rated voltage as marked on the tester (1000 volts AC).
âąî Detection above 12V is speciïŹed under "normal" conditions as speciïŹed below. The tester may
detect at a different threshold at different conditions, or may not detect at all unless:
âąî The tip of the tester is within 0.25" of an AC voltage source radiating unimpeded.
âąî The user is holding the body of the tester with his or her bare hand.
âąî The user is standing on or connected to earth ground.
âąî The air humidity is nominal (50% relative humidity).
âąî The tester is held still.
âąî Always wear approved eye protection.
âąî Comply with local and national safety requirements.
âąî If this product is used in a manner not speciïŹed by the manufacturer, protection provided by the
product may be affected.
Cleaning Tester:
âąî Tester contains sensitive electronic components; do not submerse in liquid.
âąî Do not use alcohol, ammonia or cleaners containing solvents to clean tester.
âąî Gently wipe the tester with Klein Kleaners
Âź
(CAT. # 51425), a damp cloth or
a cloth containing a mild cleaning solution.
âąî Make sure the tester is completely dry prior to operation.
DISPOSAL:
âąî Do not throw depleted batteries away; please recycle properly.
âąî Do not throw tester away, please recycle properly.
âąî Please see or www.epa.gov www.erecycle.org for additional information.
WARRANTY: www.kleintools.com/warranty
Product specificaties
Merk: | Klein Tools |
Categorie: | Meetapparatuur |
Model: | NCVT-2 |
Heb je hulp nodig?
Als je hulp nodig hebt met Klein Tools NCVT-2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Klein Tools
13 Januari 2025
13 Januari 2025
18 November 2024
12 November 2024
24 September 2024
21 September 2024
21 September 2024
18 Juni 2024
18 Juni 2024
18 Juni 2024
Handleiding Meetapparatuur
- Meetapparatuur Bosch
- Meetapparatuur Panasonic
- Meetapparatuur DeWalt
- Meetapparatuur Fysic
- Meetapparatuur Honeywell
- Meetapparatuur Pioneer
- Meetapparatuur Topcom
- Meetapparatuur ABB
- Meetapparatuur Ade
- Meetapparatuur Aktobis
- Meetapparatuur Albrecht
- Meetapparatuur Alecto
- Meetapparatuur Amprobe
- Meetapparatuur Ansmann
- Meetapparatuur AS - Schwabe
- Meetapparatuur Basetech
- Meetapparatuur Be Cool
- Meetapparatuur Beha-Amprobe
- Meetapparatuur Benning
- Meetapparatuur Beurer
- Meetapparatuur Bresser
- Meetapparatuur Bruder Mannesmann
- Meetapparatuur Burg-Wachter
- Meetapparatuur Danfoss
- Meetapparatuur Digitus
- Meetapparatuur Duro Pro
- Meetapparatuur EBERLE
- Meetapparatuur Einhell
- Meetapparatuur Eizo
- Meetapparatuur Elgato
- Meetapparatuur Enda
- Meetapparatuur Entes
- Meetapparatuur Extech
- Meetapparatuur Finder
- Meetapparatuur Flex
- Meetapparatuur Flir
- Meetapparatuur Fluke
- Meetapparatuur Goclever
- Meetapparatuur Goobay
- Meetapparatuur Gossen Metrawatt
- Meetapparatuur Grohe
- Meetapparatuur Gude
- Meetapparatuur Hager
- Meetapparatuur Hama
- Meetapparatuur Holzmann
- Meetapparatuur Homedics
- Meetapparatuur Ideal
- Meetapparatuur IHealth
- Meetapparatuur Kern
- Meetapparatuur Kogan
- Meetapparatuur Kopp
- Meetapparatuur LaCie
- Meetapparatuur Laica
- Meetapparatuur Lanaform
- Meetapparatuur Laserliner
- Meetapparatuur Livington
- Meetapparatuur Logilink
- Meetapparatuur Maximum
- Meetapparatuur Megasat
- Meetapparatuur Megger
- Meetapparatuur Metrix
- Meetapparatuur Microlife
- Meetapparatuur Midland
- Meetapparatuur Milwaukee
- Meetapparatuur Mitsubishi
- Meetapparatuur Monacor
- Meetapparatuur Muller
- Meetapparatuur Nedis
- Meetapparatuur PCE
- Meetapparatuur PCE Instruments
- Meetapparatuur Perel
- Meetapparatuur Powerfix
- Meetapparatuur Pyle
- Meetapparatuur Reely
- Meetapparatuur RK Technology
- Meetapparatuur Rossmax
- Meetapparatuur Sanwa
- Meetapparatuur Sekonic
- Meetapparatuur Shimano
- Meetapparatuur Silvercrest
- Meetapparatuur Silverline
- Meetapparatuur Soehnle
- Meetapparatuur Steinberg
- Meetapparatuur Technics
- Meetapparatuur Techno Line
- Meetapparatuur Technoline
- Meetapparatuur TFA
- Meetapparatuur Toolland
- Meetapparatuur Trotec
- Meetapparatuur Truelife
- Meetapparatuur Uni-T
- Meetapparatuur VDO
- Meetapparatuur Velleman
- Meetapparatuur VirtuFit
- Meetapparatuur Voltcraft
- Meetapparatuur Wachendorff
- Meetapparatuur Westfalia
- Meetapparatuur Joy-it
- Meetapparatuur Omnitronic
- Meetapparatuur Oregon Scientific
- Meetapparatuur Black And Decker
- Meetapparatuur Continental Edison
- Meetapparatuur CSL
- Meetapparatuur Peak
- Meetapparatuur Cocraft
- Meetapparatuur Meec Tools
- Meetapparatuur Soler And Palau
- Meetapparatuur Sauter
- Meetapparatuur Festo
- Meetapparatuur Proficare
- Meetapparatuur Eurolite
- Meetapparatuur SIIG
- Meetapparatuur RIDGID
- Meetapparatuur REV
- Meetapparatuur MSW
- Meetapparatuur SHX
- Meetapparatuur Victron Energy
- Meetapparatuur Carrier
- Meetapparatuur Fantini Cosmi
- Meetapparatuur Vemer
- Meetapparatuur Lund
- Meetapparatuur Testo
- Meetapparatuur Circutor
- Meetapparatuur Eastron
- Meetapparatuur Stabila
- Meetapparatuur Testboy
- Meetapparatuur Hazet
- Meetapparatuur Yato
- Meetapparatuur IFM
- Meetapparatuur Wago
- Meetapparatuur GW Instek
- Meetapparatuur Kyoritsu
- Meetapparatuur Dahua Technology
- Meetapparatuur Owon
- Meetapparatuur Eltako
- Meetapparatuur Cablexpert
- Meetapparatuur Wentronic
- Meetapparatuur Comark
- Meetapparatuur Clean Air Optima
- Meetapparatuur ORNO
- Meetapparatuur Multimetrix
- Meetapparatuur Etymotic
- Meetapparatuur Hameg
- Meetapparatuur PICO
- Meetapparatuur Sonel
- Meetapparatuur YSI
- Meetapparatuur TFA Dostmann
- Meetapparatuur Werma
- Meetapparatuur Greisinger
- Meetapparatuur Testec
- Meetapparatuur Hikmicro
- Meetapparatuur Vimar
- Meetapparatuur Kreg
- Meetapparatuur Kemo
- Meetapparatuur Pancontrol
- Meetapparatuur SRS
- Meetapparatuur H-Tronic
- Meetapparatuur Ebro
- Meetapparatuur X-Rite
- Meetapparatuur Tempest
- Meetapparatuur Arya
- Meetapparatuur PeakTech
- Meetapparatuur Tru Components
- Meetapparatuur Emko
- Meetapparatuur KS Tools
- Meetapparatuur Trumeter
- Meetapparatuur Aeros
- Meetapparatuur Delta Ohm
- Meetapparatuur Aqua Master Tools
- Meetapparatuur Hanna
- Meetapparatuur Atmel
- Meetapparatuur Qualita
- Meetapparatuur MGL Avionics
- Meetapparatuur Adwa
- Meetapparatuur Chauvin Arnoux
- Meetapparatuur AREXX
- Meetapparatuur UHoo
- Meetapparatuur CEM
- Meetapparatuur Jonard Tools
- Meetapparatuur TDE Instruments
- Meetapparatuur CESYS
- Meetapparatuur Angler
- Meetapparatuur Aerospace Logic
- Meetapparatuur Zircon
- Meetapparatuur BJZ
- Meetapparatuur Johnson Level
- Meetapparatuur GMW
- Meetapparatuur SOEKS
- Meetapparatuur Rotronic
- Meetapparatuur Apollo Ultrasonic
- Meetapparatuur Softing
- Meetapparatuur Weltron
- Meetapparatuur Oscium
- Meetapparatuur Janitza
- Meetapparatuur Condtrol
- Meetapparatuur J.P. Instruments
- Meetapparatuur WeidmĂŒller
- Meetapparatuur Ermenrich
- Meetapparatuur Siglent
- Meetapparatuur INFICON
- Meetapparatuur Qubino
- Meetapparatuur Lascar Electronics
- Meetapparatuur HT Instruments
- Meetapparatuur P3 International
- Meetapparatuur Beckmann & Egle
- Meetapparatuur Seek Thermal
- Meetapparatuur Motrona
- Meetapparatuur KĂŒbler
- Meetapparatuur AkYtec
- Meetapparatuur Tempo
- Meetapparatuur Camille Bauer
- Meetapparatuur Blebox
- Meetapparatuur Seaward
- Meetapparatuur HOZO Design
- Meetapparatuur Corentium
- Meetapparatuur GQ
- Meetapparatuur Tektronix
- Meetapparatuur Dostmann Electronic
- Meetapparatuur Murideo
- Meetapparatuur SecuTech
- Meetapparatuur NetPeppers
- Meetapparatuur SensoProtect
- Meetapparatuur Water-i.d.
- Meetapparatuur ZKETECH
- Meetapparatuur LabNation
- Meetapparatuur Electronics International
- Meetapparatuur Cliff
- Meetapparatuur ClimeMET
- Meetapparatuur Fixpoint
- Meetapparatuur Stahlwille
- Meetapparatuur MASIMO
- Meetapparatuur Milesight
- Meetapparatuur Noyafa
- Meetapparatuur Stamos
- Meetapparatuur Brookhuis
- Meetapparatuur Crowcon
- Meetapparatuur Aeroqual
- Meetapparatuur Intact
- Meetapparatuur PQ Plus
- Meetapparatuur DriveTest
- Meetapparatuur Helvi
Nieuwste handleidingen voor Meetapparatuur
13 Januari 2025
13 Januari 2025
13 Januari 2025
13 Januari 2025
13 Januari 2025
9 Januari 2025
8 Januari 2025
8 Januari 2025
8 Januari 2025
8 Januari 2025