INSTRUCTION MANUAL
ENGLISH
• AUTO-RANGING
WITH DATA HOLD
• AUDIBLE
CONTINUITY
• BATTERY TEST
• PERFORMS
STANDARD AND
GFCI WIRING
FAULT TESTS
• INDICATES
A CIRCUIT'S
BREAKER IN
FIND MODE
FRANÇAIS p. 25
ESPAÑOL pg. 13
Multi-Tester DMM with
Receptacle Tester
ET270
2m
CAT III
600V
600V
40M
Ω
5001748
2
GENERAL SPECIFICATIONS
Klein Tools' ET270 is an auto-ranging digital multi-tester that measures
AC/DC voltage, resistance, continuity, and performs a battery test. It also
tests wiring conditions in standard 120V and GFCI electrical receptacles
and inspects North American GFCI devices.
• Environment:
Indoor. DO NOT expose to moisture, rain, or snow.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: ° ° ° °32 F to 104 F (0 C to 40 C)
• Storage Temp: ° ° ° °14 F to 140 F (-10 C to 60 C)
• Accuracy: Values stated at 65°F to 83°F (18°C to 28°C)
• Temp Coef cient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 6.41" × 3.13" × 1.84" (162.7 × 79.4 × 46.6 mm)
• Weight: 8.9 oz. (250 g)
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-033, 1436.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-033, 160.
IEC EN 61010-1, 61010-2-033, 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2 m)
• Safety Rating: CAT III 600V, Class 2, Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
VOLTAGE (AUTO-RANGING)
Function Range Resolution Accuracy
AC Voltage
(V AC)
400.0V 100mV ±(1.2% + 5 digits)
600V 1V ±(1.2% + 3 digits)
DC Voltage
(V DC)
4000mV 1mV ±(1.0% + 5 digits)
40.00V 10mV
±(1.0% + 3 digits)400.0V 100mV
600V 1V
Input Impedance: 10MΩ
Frequency Range: 50 to 60Hz
Maximum Input: 600V AC RMS or 600V DC
RESISTANCE (AUTO-RANGING)
Range Resolution Accuracy
400.0Ω 0.1Ω
±(1.0% + 5 digits)
4.000kΩ 1Ω
40.00kΩ 10Ω
400.0kΩ 100Ω
4.000MΩ 1kΩ ±(1.2% + 5 digits)
40.00MΩ 10kΩ ±(3.0% + 5 digits)
Maximum Input: 600V DC or 600V AC RMS
BATTERY TEST
Voltage Resolution Accuracy
9V 10mV ±(1.0% + 5 digits)
1.5V 1mV
Test Current: 9V (11~22.5mA), 1.5V (8~18mA)
OUTLET* TEST
Voltage Resolution Accuracy
30V AC - 150 V AC 1V ±(2.0% + 2 digits)
*NOTE: For North American, 120V, 50-60Hz, 3-wire receptacles only.
• Audible signal <10ΩContinuity Check:
• 3 samples per secondSampling Frequency:
• "OL" indicated on display, overload protection Overload:
600V RMS in all settings
• "-" on display indicates negative polarityPolarity:
• 3-3/4 digit, 4000 Count LCDDisplay: