Klein Tools CL800 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Klein Tools CL800 (48 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 61 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/48
INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 33
ESPAÑOL pg. 17
600A AC/DC Au
Digital Clamp
True RMS
Measurement
Technology
• NON-CONTACT
VOLTAGE TESTER
• LOW IMPEDANCE
• DATA & RANGE
HOLD
• AUDIBLE CONTINUITY
• DIODE TEST
• CAPACITANCE &
FREQUENCY
Ω
4007177
CL800
2
m
IP40
-14° –
1000°F
(-26° –
538°C)
2
GENERAL SPECIFICATIONS
Klein Tools CL800 is an automatically ranging true root mean square
(TRMS) digital clamp-meter that measures AC/DC current via the
clamp, measures AC/DC voltage, resistance, continuity, frequency,
capacitance, and tests diodes via test-leads, and temperature via a
thermocouple probe. It also features a Low Impedance (LoZ) mode
for identifying and eliminating ghost or stray voltages.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: ° ° ° °32 to 104 F (0 to 40 C)
• Storage Temp: ° ° ° °14 to 140 F (-10 to 60 C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefcient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 9.09" x 3.82" x 1.54" (231 x 97 x 39 mm)
• Weight: 12.5 oz. (354 g) including batteries
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-032,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-032, 61010-2-033.
IEC EN 61010-1, 61010-2-032,
61010-2-033, 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CAT IV 600V, CAT III 1000V, Class 2,
Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy (50/60 Hz)
AC Voltage
(V AC)
6.000V 1mV ±(1.5% + 5 digits)
60.00V 10mV ±(1.2% + 5 digits)
600.0V 100mV
1000V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
600mV 0.1mV ±(1.0% + 8 digits)
6.000V 1mV
±(1.0% + 3 digits)60.00V 10mV
600.0V 100mV
1000V 1V ±(1.2% + 3 digits)
Input Impedance: Frequency Range:10MΩ 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
AC Current
(A AC)
60.00A 10mA ±(2.0% + 8 digits)
600.0A 100mA ±(2.0% + 5 digits)
DC Current
(A DC)
60.00A 10mA ±(2.0% + 8 digits)
600.0A 100mA ±(2.0% + 5 digits)
Frequency Range: 50 to 60Hz
Function Range Resolution Accuracy
Resistance
600.0Ω 0.1Ω
±(1.5% + 5 digits)
6.000KΩ 1Ω
60.00kΩ 10Ω
600.0kΩ 100Ω
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 10 digits)
Maximum Input: 600V AC RMS or 600V DC
Capacitance
60.00nF 0.010nF ±(5.0% + 35 digits)
600.0nF 0.1nF
±(3.0% + 5 digits)6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF ±(5.0% + 5 digits)
6000µF 1µF
Maximum Input: 600V AC RMS or 600V DC
Temperature
(Fahrenheit)
-14° to 32°F
0.1 to 1
°F
±(2.0% + 9
°F
)
33° °F to 752
±(1.0% + 5.4
°F
)
753° °F to 1000
±(2.0% + 9
°F
)
Temperature
(Celsius)
-26° to 0°C
0.1 to 1
°C
±(2.0% + 5
°C
)
1° to 400°C
±(1.0% + 3
°C
)
401° to 538°C
±(2.0% + 5
°C
)