Klein Tools CL220 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Klein Tools CL220 (44 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 81 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/44
INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 29
ESPAÑOL pg. 15
400A AC Auto
Digital Clamp
• NON-CONTACT
VOLTAGE TESTIN
• AUTO-RANGING
• DATA HOLD
• RANGE HOLD
• TEMPERATURE
• AUDIBLE CONTI
600V
400A
20M
Ω
5001748
CL220
-40° –
1832°F
-40° –
1000°C
2m
True RM
Measuremen
Technology
CAT III
600V
2
GENERAL SPECIFICATIONS
Klein Tools CL220 is an automatically ranging, true root-mean-
square (TRMS) digital clamp-meter that measures AC current via the
clamp, AC/DC voltage, resistance and continuity via test-leads, and
temperature via a thermocouple probe.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <95% non-condensing
• Operating Temp: ° ° ° °32 to 122 F (0 to 50 C)
• Storage Temp: ° ° ° °14 to 122 F (-10 to 50 C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefcient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 8.46" x 3.54" x 1.50" (215 x 90 x 38 mm)
• Weight: 11.04 oz. (313 g) including batteries
• Calibration: Accurate for one year
• Auto Power-Off (APO): After approx. 10 minutes of inactivity
• Standards: IEC EN 61010-1, 61010-2-032, 61010-2-033.
IEC EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1,
61010-2-032,61010-2-033;
Certified to CSA STD.C22.2 NO. 61010-1,
61010-2-032,61010-2-033.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CATIII 600V, Class 2, Double insulation
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
AC Voltage
(V AC)
200.0mV 0.1mV ±(2.5% + 10 digits)
2.000V 1mV
±(2.0% + 5 digits)
20.00V 10mV
200.0V 100mV
600V 1V
DC Voltage
(V DC)
200.0mV 0.1mV ±(1.0% + 8 digits)
2.000V 1mV
±(1.0% + 3 digits)
20.00V 10mV
200.0V 100mV
600V 1V
Input Impedance: 10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
2.000A 1mA ±(2.5% + 30 digits)
20.00A 10mA
±(2.0% + 10 digits)200.0A 100mA
400A 1A
Frequency Range: 50 to 60Hz
Resistance
200.0Ω 0.1Ω ±(1.2% + 5 digits)
2.000KΩ 1Ω
±(1.2% + 3 digits)
20.00kΩ 10Ω
200.0kΩ 100Ω
2.000MΩ 1kΩ
20.00MΩ 10kΩ ±(2.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
°F
-40° to 10°F
1
°F
±(1.2% + 7 digits)
11° to 1832°F
±(1.2% + 6 digits)
Temperature
°C
-40° to -12°C
1
°C ±(1.2% + 4 digits)
-11° to -1000°C
±(1.2% + 3 digits)
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
• Audible signal <10Ω, max current 1.5mAContinuity Check:
• 3 samples per secondSampling Frequency:
• "OL" indicated on displayOverload:
• "-" on display indicates negative polarityPolarity:
• 3 ½ digit, 2000 Count LCDDisplay:


Product specificaties

Merk: Klein Tools
Categorie: Meetapparatuur
Model: CL220

Heb je hulp nodig?

Als je hulp nodig hebt met Klein Tools CL220 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Klein Tools

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur