Kelvinator KSV70CRC Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Kelvinator KSV70CRC (18 pagina's) in de categorie Airconditioner - Aircooler. Deze handleiding was nuttig voor 25 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/18
Inverter Split
Room Air Conditioner
User Manual
KSV26CRC, KSV26HRC, KSV35CRC,
KSV35HRC, KSV53HRC, KSV62HRC,
KSV70CRC, KSV70HRC, KSV80HRC
Refrigerant R410A
i Contents Kelvinator Air Conditioning
Congratulations and thank you for choosing our Inverter
split-type room air conditioner. We are sure you willnd
your new air conditioner a pleasure to use. Before you use
the air conditioner, we recommend that you read through
the entire user manual, which provides the description of
the air conditioner and its functions.
To avoid the risks that are always present when you use an
electrical appliance, it is important that the air conditioner
is installed correctly and that you read the safety instructions
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not
damaged. If in doubt, do not use the air conditioner but
contact your local Electrolux Customer Care Centre.
environmental tip
Information on disposal for users
Most of the packing materials are recyclable.
Please dispose of those materials through your local
recycling depot or by placing them in appropriate
collection containers.
If you wish to discard this air conditioner, please contact
your local authorities and ask for the correct method
of disposal.
caution
The air conditioner is not intended for use by young
children or inrmed persons without supervision.
Young children should be supervised to ensure that
they do not play with the air conditioner.
Contact an authorised installer for installation of this unit.
Contact an authorised service technician for repair or
maintenance of this unit.
If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only.
Installation work must be performed in accordance
with the national wiring Standards by authorised
personnel only.
Conditions of use
This appliance is intended to be useed in household and
similar applications such as:
Staff kitchen areas in shops, offices and other working
environments
Farm houses
By clients in hotels, motels, and other residential
type environments
Bed and breakfast type environments
Contents ............................................................................. i
Quickstart guide ............................................................... ii
Parts identification ........................................................... iii
Safety precautions ............................................................1
Warning .........................................................................................1
Caution ..........................................................................................1
Using the remote control ............................................................ 2
Features of the remote control .........................................3
Clock button .................................................................................4
Light button 4 ..................................................................................
Turbo button.................................................................................4
X-Fan button .................................................................................4
Time On/Off buttons 4 ...................................................................
Swing buttons ...............................................................................4
I Feel button 5 .................................................................................
Quiet button ................................................................................. 5
Sleep button ................................................................................. 5
Changing batteries ...........................................................6
Emergency operation........................................................6
Care and cleaning .............................................................7
Operation tips ................................................................... 8
Troubleshooting ................................................................ 9
Installation checklist ........................................................ 12
Important notes
Contact an authorised installer for installation of this unit.
Contact an authorised service technician for repair or
maintenance of this unit.
The socket oulet required to supply power must be
connected and commissioned by a licenced contractor.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person
responsible for their safety.
Young children should be supervised to ensure that they
do not play with the air conditioner.
If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only.
Installation work must be performed in accordance with
the national wiring standards and the electricity suppliers
service rules by authorised personnel only.
If the system is to be moved to another location or
disposed of, only a suitably qualied person is permitted
to undertake such work.
Take care not to catch ngers on the fan blade when
adjusting vertical louvres.
This air conditioner uses R410A refrigerant (Conrm
before installation).
Congratulations Contents
Quickstart guide
ii Quickstart guide Kelvinator Air Conditioning
2
1
3
4
6
7
5
8
9
Optional operations
6. Press the SLEEP button (6) to select the sleep mode.
7. The TIMER ON and TIMER OFF buttons (7) can be used
to set automatic start and stop for the air conditioner,
(see detailed instructions for more information)
8. The light button (8) can be used to swith on or off the
display on the front panel of the indoor unit.
9. Press TURBO button, can realize the ON and OFF of
TURBO function.
Special functions
This function indicates that moisture on evaporator of indoor
unit will be blowed after the unit is stopped to avoid mould.
X-FAN (Air Purge)
When the X-fan function is on, the fan will continue to run
for 10 minutes at low speed after the off button is pressed in
order to purge the air conditioner of all moisture to avoid the
growth of mould.
About AUTO RUN
When AUTO RUN mode is selected, the set temperature will
not be displayed on the LCD, the unit will be in accordance
with the room temperature automatically to select the
suitable running method and to make ambient comfortable.
Turbo function
The Turbo function operates a higher than normal fan speed
to allow for rapid heating or cooling.
Remote lock
Press SWING-V and ION-FILTER buttons simultaneously to
lock or unlock the keyboard. If the remote control is locked,
the icon will be displayed on it, in which case, press any
button, the mark will flicker three times. If the keyboard
is unlocked, the mark will disappear.
Switch between Centigrade and Farenheit
With the air conditinioner switched off, press the SWING-H
and ION-FILTER buttons simultaneously to switch between
°C and °F .
Energy saving
Press ION-FILTER and CLOCK simultaneously to start or stop
enegry saving funtion. The remote control display will show
“SE” when this function is active.
Low heat mode
In heating mode, pressing ION-FILTER and CLOCK
simultaneously will put the air conditioner into a low heat
mode that will operate to a temperature of 8°C. Repeat the
operation to quit the function.
General operation
1. Once power is connected, press the ON/OFF button (1)
and the air conditioner will start to run.
Note: When the power is connected the main louver will
close automatically
2. Press the mode button (2) to select the desired runnng
mode (heating, cooling, fan only or dehumidify).
3. Pressing or button (3) to select the desired
temperature. (It is unnecessary to set the temperature
in AUTO MODE.)
4. Pressing the fan button (4) will allow you to select from
6 different fan speeds from high to low, including an
AUTO setting.
5. The swing buttons (5) will allow you to select horizontal
(H) or vertical (V) swing of the air guding louvers.
Cool
Dry
Heat
Set temp
Power
The icons displayed on the indoor unit:


Product specificaties

Merk: Kelvinator
Categorie: Airconditioner - Aircooler
Model: KSV70CRC

Heb je hulp nodig?

Als je hulp nodig hebt met Kelvinator KSV70CRC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airconditioner - Aircooler Kelvinator

Handleiding Airconditioner - Aircooler