Automatic switch 180° 1.10 m
Light Management
Standard automatic switch 180° 1.10 m
Art.-No.: ..1180..
Universal automatic switch 180° 1.10 m
Art.-No.: ..1180-1..
Operationsmanual
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Do not press on the sensor window. Device can be damaged.
The device is not suitable for use as a burglar alarm or other alarm.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
picture 1
(1) Flush-mounted insert
(2) Frame
(3) Motion detector cover
(4) Cover plate / slide switch
1/14
32540233
J:0082540233 26.07.2010
Automatic switch standard
picture 2: Automatic switch standard
Automatic switch universal
picture 3: Automatic switch universal
(5) Adjuster, sensitivity
(6) Adjuster, brightness
(7) Operating mode switch
(8) Adjuster, run-on time
3 Function
Intended use
- Automatic switching of lighting depending on the heat motion and ambient brightness.
- Operation with concealed insert for dimming, switching or extension insert, 3-wire
- Interior mounting on flush-mounted insert at a height of 1.1 m.
2/14
32540233
J:0082540233 26.07.2010
Light Management
Automatic switch 180° 1.10 m
Product characteristics
Automatic switch standard
- Sensitivity and brightness threshold settable
- Manual switch-on possible via extension insert, 2-wire, or installation button
- 18 lens segments in 2 recording levels
- Extension of the detection area in combination with the 3-wire extension insert
- Detection area can be limited using cover plate
i Dimming inserts can only execute switching functions.
Automatic switch universal
- Run-on time, sensitivity and brightness threshold settable
- Teach function to save the current brightness as the new brightness threshold.
- Operating mode switch for Automatic operation, Continuous on or Continuous off
- Short-time operation, e.g. to control acoustic signal encoders
- Manual switch-on possible via extension insert, 2-wire, or installation button
- With the dimmer insert, it is possible to change the brightness using a 2-wire extension
insert
- Switch-on brightness can be saved with the dimmer insert
- With the dimmer insert, the dim-down function is possible at the end of the run-on time
- 18 lens segments in 2 recording levels
- Extension of the detection area in combination with the 3-wire extension insert
- Detection area can be limited using cover plate
- High protection against ambient light
Automatic operation
The controller detects heat motions of people, animals and objects.
- The light is switched on if a person enters the monitored detection area and the brightness
is below the set threshold.
Each detected movement restarts the run-on time.
- The light is switched off if no more movement is detected in the detection area and the run-
on time has elapsed.
Light oscillations e.g. due to the cooling of bulbs are prevented via interlock times in the
automatic switch. No switching commands are performed during the interlock.
Automatic switch standard approx. 3 seconds
Automatic switch universal: 0.2 to 3 seconds, dynamic.
Automatic switch universal: The day/night and night/day switch-over is performed only after the
brightness is above or below the threshold for approx. 10 seconds. This prevents the motion
detector from switching to Night mode is there is brief shadow or to Day mode if there is brief
light.
Behaviour in case of mains failure for automatic switch standard
- Less than 0.2 seconds: the old switching position is restored after mains return.
- 0.2 seconds to approx. 1 seconds: when the power returns, the lighting is switched on
again for the run-on time.
- Longer than 1 second: when the power returns, the motion detector carries out a self test
for approx. 60 seconds. The lighting is switched on during the self test. Then the lighting
switches off for the length of the run-on time.
Behaviour in case of mains failure for automatic switch universal
- Less than 0.2 seconds: the old switching position is restored after mains return.
- 0.2 seconds to approx. 2 seconds: when the power returns, the lighting is switched on
again for the run-on time.
- Longer than 2 seconds: when the power returns, the motion detector carries out a self test
for approx. 90 seconds. The lighting is switched on during the self test. Then the lighting
switches off briefly, and then on again for the length of the run-on time.
i In the Continuous on and Continuous off operating modes, the light is switched on or off
after the self-test.
i A power failure of longer than 2 seconds causes the loss of the switch-on brightness and
the brightness threshold saved via the Teach function.
3/14
32540233
J:0082540233 26.07.2010
Light Management
Automatic switch 180° 1.10 m


Product specificaties

Merk: Jung
Categorie: Niet gecategoriseerd
Model: LS539WWLEDLW-12

Heb je hulp nodig?

Als je hulp nodig hebt met Jung LS539WWLEDLW-12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Jung

Jung

Jung MAAL1133 Handleiding

14 December 2024
Jung

Jung MAGCR1193 Handleiding

10 December 2024
Jung

Jung LCZ982BF Handleiding

10 December 2024
Jung

Jung LCZ983BF Handleiding

10 December 2024
Jung

Jung WS10T Handleiding

10 December 2024
Jung

Jung MAAL1193 Handleiding

10 December 2024
Jung

Jung LCZ981BF Handleiding

10 December 2024
Jung

Jung ABAS1561.07 Handleiding

10 December 2024
Jung

Jung MALS1193 Handleiding

10 December 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd