Joy-it VAM-10010 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Joy-it VAM-10010 (4 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
VAM - 10010
Spannungs- und Strommessgerät
1. ALLGEMEINE INFORMATIONEN
Dear customer,
thank you for choosing our product. In the following, we will show you how
to use this device.
Should you encounter any unexpected problems during use, please do not
hesitate to contact us.
2. TECHNICAL SPECIFICATIONS
3. WIRING
Operating voltage
Current at 3,6 V
Current at 12 V
Measuring ranges
Operating temperatures
Measurement accuracy
voltage
Dimensions
Weight
3.5 - 30 V
approx. 9 mA
approx. 15 mA
0 - 99.9 V / 0 - 9.99 A
-10 - 65 °C
± 0.5 %
48 x 29 x 22 mm
20 g
Measurement accuracy
current
± 1 %
Isolated power supply
The current sources must be
isolated. It must not be a
connection between both
circuits.
load
3.5 - 30 V for tester
load for tester
measuring line (0 - 99.9
input of current measurement
output of current measurement
isolated power supply
4. TECHNICAL DRAWING
Use with a DC-DC converter
“ground tester“ is not connected


Product specificaties

Merk: Joy-it
Categorie: Meetapparatuur
Model: VAM-10010

Heb je hulp nodig?

Als je hulp nodig hebt met Joy-it VAM-10010 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Joy-it

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur