VAM - 10010
Spannungs- und Strommessgerät
1. ALLGEMEINE INFORMATIONEN
Dear customer,
thank you for choosing our product. In the following, we will show you how
to use this device.
Should you encounter any unexpected problems during use, please do not
hesitate to contact us.
2. TECHNICAL SPECIFICATIONS
3. WIRING
Operating voltage
Current at 3,6 V
Current at 12 V
Measuring ranges
Operating temperatures
Measurement accuracy
voltage
Dimensions
Weight
3.5 - 30 V
approx. 9 mA
approx. 15 mA
0 - 99.9 V / 0 - 9.99 A
-10 - 65 °C
± 0.5 %
48 x 29 x 22 mm
20 g
Measurement accuracy
current
± 1 %
Isolated power supply
The current sources must be
isolated. It must not be a
connection between both
circuits.
load
3.5 - 30 V for tester
load for tester
measuring line (0 - 99.9
input of current measurement
output of current measurement
isolated power supply
4. TECHNICAL DRAWING
Use with a DC-DC converter
“ground tester“ is not connected