Jotul GF 520 DV IPI Handleiding

Jotul Kachel GF 520 DV IPI

Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor Jotul GF 520 DV IPI (44 pagina's) in de categorie Kachel. Deze handleiding was nuttig voor 15 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/44
1
130084_Rev A GF 520 DV IPI 11/22
Jรธtul GF 520 DV IPI
Direct Vent Gas Stove
Installation and
Operation Instructions
โ€“ Do not store or use gasoline or other
๏ฌ‚ammable vapors and liquids in the
vicinity of this or any other appliance.
โ€“ WHAT TO DO IF YOU SMELL GAS
โ€ข Do not try to light any appliance.
โ€ข Do not touch any electrical switch; do
not use any phone in your building.
โ€ข Leave the building immediately.
โ€ข Immediately call your gas supplier from a
neighborโ€™s phone. Follow the gas supplierโ€™s
instructions.
โ€ข If you cannot reach your gas supplier,
call the ๏ฌre department.
โ€“ Installation and service must be performed
by a quali๏ฌed installer, service agency or
the gas supplier.
โ€“ In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
WARNING: If the information in these
instructions is not followed exactly, a ๏ฌre
or explosion may result causing property
damage, personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or mobile
home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
OWNER: Retain this manual for future reference.
๎˜Ÿ๎˜ž๎˜๎˜œ๎˜›๎˜›๎˜š๎˜™๎˜›๎˜ž๎˜˜๎˜™๎˜—๎˜š๎˜–๎˜•๎˜™๎˜˜๎˜ž๎˜”๎˜“๎˜ž๎˜›๎˜™๎˜˜๎˜’๎˜‘๎˜™๎˜ž๎˜”๎˜๎˜™๎˜ž๎˜๎˜’๎˜›๎˜•๎˜ž๎˜๎˜œ๎˜๎˜œ๎˜›๎˜˜
๎˜Ž๎˜›๎˜“๎˜๎˜ž๎˜”๎˜๎˜™๎˜ž๎˜–๎˜Œ๎˜œ๎˜—๎˜—๎˜ž๎˜‹๎˜š๎˜™๎˜Š๎˜š๎˜•๎˜–๎˜ž๎˜œ๎˜›๎˜™๎˜œ๎˜ž๎˜š๎˜—๎˜ž๎˜‰๎˜›๎˜“๎˜‹๎˜š๎˜˜๎˜™๎˜˜๎˜ž๎˜Š๎˜š๎˜”๎˜๎˜ž๎˜”๎˜๎˜š๎˜—
๎˜œ๎˜‰๎˜‰๎˜Œ๎˜š๎˜œ๎˜•๎˜‘๎˜™๎˜ž๎˜œ๎˜•๎˜˜๎˜ž๎˜—๎˜๎˜œ๎˜Œ๎˜Œ๎˜ž๎˜๎˜™๎˜ž๎˜š๎˜•๎˜—๎˜”๎˜œ๎˜Œ๎˜Œ๎˜™๎˜˜๎˜ž๎˜Ž๎˜“๎˜›๎˜ž๎˜”๎˜๎˜™๎˜ž๎˜‰๎˜›๎˜“๎˜”๎˜™๎˜‘๎˜”๎˜š๎˜“๎˜•
๎˜“๎˜Ž๎˜ž๎˜‘๎˜๎˜š๎˜Œ๎˜˜๎˜›๎˜™๎˜•๎˜ž๎˜œ๎˜•๎˜˜๎˜ž๎˜“๎˜”๎˜๎˜™๎˜›๎˜ž๎˜œ๎˜”๎˜ˆ๎˜›๎˜š๎˜—๎˜‡๎˜ž๎˜š๎˜•๎˜˜๎˜š๎˜‹๎˜š๎˜˜๎˜’๎˜œ๎˜Œ๎˜—๎˜†
๎˜Ÿ๎˜ž๎˜๎˜œ๎˜›๎˜š๎˜™๎˜˜๎˜˜๎˜Ÿ๎˜ž๎˜๎˜œ๎˜œ
๎˜›๎˜š๎˜™๎˜˜๎˜—๎˜Ÿ๎˜–๎˜™๎˜•๎˜”๎˜˜๎˜“
๎˜—๎˜–๎˜•๎˜–๎˜”๎˜Ÿ๎˜š๎˜œ๎˜œ๎˜’๎˜ž๎˜Ÿ๎˜›๎˜‘๎˜๎˜œ๎˜๎˜•๎˜—๎˜”
๎˜๎˜’๎˜Ÿ๎˜๎˜’๎˜™๎˜›๎˜‘๎˜Ÿ๎˜Ž๎˜œ๎˜š๎˜˜๎˜˜๎˜“
๎˜“๎˜ž๎˜œ๎˜—๎˜ž๎˜๎˜œ๎˜๎˜ž๎˜’๎˜‘๎˜Ÿ๎˜œ๎˜›๎˜š๎˜™๎˜˜๎˜˜
๎˜™๎˜”๎˜๎˜๎˜œ๎˜Ÿ๎˜›๎˜’๎˜’๎˜œ๎˜—๎˜๎˜“
๎˜“๎˜™๎˜—๎˜›๎˜–๎˜”
๎˜Ÿ
Certi๏ฌed to ANSI Z21.88-2019 โ€ข CSA 2.33-2019
and CAN/CGA 2.17-M17.
Pilot-on-Demand Ignition
130084_Rev A GF 520 DV IPI 11/22
We recommend that
our gas products be
installed and serviced
by professionals who are
certi๏ฌed in the U.S. by
the National Fireplace
Instituteยฎ (NFI) as NFI
Gas Specialists.
Jรธtul GF 520 DV IPI
Suggested Tools for Installation and Service
โ€ข External regulator (for Propane only)
โ€ข Piping which complies with local code
โ€ข Manual shut-o๎˜ž valve -
T-Handle required in Massachusetts
โ€ข Sediment trap - if required by code
โ€ข Tee joint
โ€ข Pipe wrench
โ€ข Pipe sealant
โ€ข 10 mm open end wrench
โ€ข 1/2โ€, 7/16โ€ open end wrench
โ€ข Phillips head screwdriver
โ€ข Flat head screwdriver
โ€ข 1/4โ€ nut driver
โ€ข Gloves
โ€ข Safety glasses
โ€ข Torx T-20 screwdriver for
Fuel Conversion
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GAS๎˜FITTER WHEN
INSTALLED IN THE COMMONWEALTH
OF MASSACHUSETTS.
1. If there is not one already present, on each ๏ฌ‚oor
level where there are bedroom(s), a carbon
monoxide detector and alarm shall be placed
in the living area outside the bedroom(s). The
carbon monoxide detector shall comply with
NFPA 720 (Current Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery powered or
both; and
c) Shall comply with NFPA 720 (Current
Edition).
3. A Product-approved vent terminal must be
used, and if applicable, a Product-approved
air intake must be used. Installation shall be
in strict compliance with the manufacturerโ€™s
instructions. A copy of the installation
instructions must remain with the appliance or
equipment at the completion of the installation.
4. A Manual gas supply line shut-o๎˜ž valve must
be installed.
THIS OWNERโ€™S MANUAL PROVIDES INFORMATION
TO ENSURE SAFE INSTALLATION AND EFFICIENT,
DEPENDABLE OPERATION. PLEASE READ THESE
INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THE
APPLIANCE.
DO NOT ATTEMPT TO ALTER OR MODIFY THE
CONSTRUCTION OF THIS APPLIANCE OR ITS
COMPONENTS. ANY MODIFICATION OR ALTERATION
WILL VOID THE WARRANTY, CERTIFICATION AND
LISTING OF THIS APPLIANCE.
THIS APPLIANCE MUST BE INSTALLED AND MAIN๎˜
TAINED BY A QUALIFIED SERVICE TECHNICIAN OR
AGENCY.
Natural Gas / 64.19%
Propane / 65.47%
Based on CSA P.4.1-15
PLEASE NOTE:
Initial Break-in
It is normal for smoke and odor to occur during the
initial stages of operation, depending upon temperatures
generated over time. This โ€œcuringโ€ condition can be
alleviated by promoting fresh air circulation within the
immediate vicinity of the appliance. Please see page 23 for
further information.
Operation Sound
Please be aware that cast iron and steel components expand
and contract with temperature ๏ฌ‚uctuations that are often
accompanied by โ€œcreakingโ€
or โ€œpingingโ€ sounds. This is
the result of natural thermal
activity.
The blower fan will also
generate a slight hum at the
low setting and progressively
increase with the velocity of
forced air.
3
130084_Rev A GF 520 DV IPI 11/22
Jรธtul GF 520 DV IPI (POD)
Manufactured and Distributed by:
Jรธtul North America
55 Hutcherson Dr.
Gorham, Maine 04038
Certi๏ฌed Test Standards
This appliance complies with National Safety standards
and is tested and listed by
Intertek Testing Services of Middleton, Wisconsin to
ANSI Z21.88-2019 โ€ข CSA 2.33-2019, โ€œVented Gas
Fireplace Heaterโ€ and CAN/CGA 2.17-M17.
Table of Contents
1. Speci๏ฌcations ....................................... 4
2. Initial Assembly 5 ...................................
3. General Information 6 ...........................
4. Safety Information 6 .............................
5. Installation Requirements 7 ....................
Floor Protection 7 ...............................................
Clearances .....................................................7-8
Mobile Home Installation 9 .................................
6. Vent Requirements ...........................10
Vertical Termination 12 .........................................
Horizontal Termination 13-15 ..............................
7. Fuel Conversion 16-19 ............................
8. Gas Connection 20 .................................
9. Gas Pressure.......................................20
10. Accessories .........................................21
Firebox Panel Kits 21-22 .....................................
11. Burner Media Installation 23 .................
Log Set 23-24 ......................................................
12. System Check ................................... 25
13. Flame Picture Adjustment 26 ...............
14. Operation Guidelines 27 ........................
Burner Operation 28 ............................................
Features Overview 29 ..........................................
Remote Control 30-32 ......................................
15. Maintenance ...................................... 33
Annual Cleaning 33 .............................................
Glass Care & Replacement 33-35 ......................
Safety Screen Replacement 36 .........................
Battery Replacement 37 ...................................
16. Appendix ............................................38
Wiring Diagram 38 ..............................................
Illustrated Parts Lists 39-41 ................................
17. Warranty Statement .........................42
18. Lighting Instructions 43 .........................
Direct Vent Gas
Heater
๎˜Ÿ WARNING:
READ AND UNDERSTAND ALL OPERATING
INSTRUCTIONS BEFORE ATTEMPTING TO
OPERATE THIS APPLIANCE. DO NOT ALLOW
ANYONE TO OPERATE THIS APPLIANCE WHO
HAS NOT READ AND UNDERSTOOD THESE
INSTRUCTIONS.
KEEP THE REMOTE CONTROL TRANSMITTER
WHERE CHILDREN CANNOT REACH IT.
๎˜Ÿ WARNING:
SEVERE INJURY. THIS APPLIANCE CAN BE SET
TO OPERATE THERMOSTATICALLY. BE AWARE
THAT THE STOVE MAY BE VERY HOT EVEN
WHEN THE BURNER IS NOT APPARENTLY OPER-
ATING.
KEEP CHILDREN AWAY FROM THE APPLIANCE.
๎˜Ÿ WARNING:
FIRE HAZARD. CAN CAUSE SEVERE INJURY
OR DEATH. THE APPLIANCE CAN TURN ON
SUDDENLY. KEEP AWAY FROM THE APPLIANCE
BURNER WHEN OPERATING THE REMOTE
SYSTEM.


Product specificaties

Merk: Jotul
Categorie: Kachel
Model: GF 520 DV IPI

Heb je hulp nodig?

Als je hulp nodig hebt met Jotul GF 520 DV IPI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Kachel Jotul

Handleiding Kachel

Nieuwste handleidingen voor Kachel