JANDY VSSHP220AUT Handleiding

JANDY Pomp VSSHP220AUT

Lees hieronder de 📖 handleiding in het Nederlandse voor JANDY VSSHP220AUT (84 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/84
ePumpâ„¢ Series
Pumps
ENGLISH | FRANÇAIS | ESPAÑOL
WARNING
INSTALLATION AND
OPERATION MANUAL
H0365700 RevE
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool
equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The
maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that
all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning
notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in
property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper
installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage,
or death.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/operator of this
equipment.
Table of Contents
Section 1. IMPORTANT SAFETY INSTRUCTIONS 3
1.1 Safety Instructions 3 ................................
1.2 Pool Pump Suction Entrapment
Prevention Guidelines 5 ..........................
Section 2. General Description 6 .............................
2.1 Introduction ........................................... 6
2.2 Description ............................................ 6
Section 3. Installation Information 7 .......................
3.1 Plumbing ............................................... 7
3.2 Electrical Installation 9 .............................
3.3 ePump Dip Switch Settings .................. 11
3.4 Pressure Testing ................................... 11
3.5 Conducting Pressure Test..................... 13
3.6 Auxiliary Load Operation 13 ......................
Section 4. Operation 15 ..............................................
4.1 Start-up ................................................. 15
Section 5. Service and Maintenance 15 ....................
5.1 Routine Maintenance 15 ............................
5.2 Winterizing the Pump 16 ...........................
Section 6. Troubleshooting and Repair 17 ...............
6.1 Troubleshooting .................................... 17
6.2 Service Technician Maintenance .......... 19
Section 7. Product Speciîš¿cations and Technical
Data 24 .......................................................
7.1 Replacement Parts List and Exploded
View 24 ......................................................
7.2 Performance Curves 26 .............................
7.3 Physical and Operational
Speciîš¿cations ....................................... 26
7.4 Replacement Motor Guide 27 ....................
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
NOTES:
EQUIPMENT INFORMATION RECORD
Page 2
Jandy® Pro Series ePump™ Series Pump | Installation and Operation Manual
ENGLISH
Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS
INJURY OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not
use this pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets. Drain covers must be certiîš¿ed to the latest
published edition of ANSI/ASME A112.19.8, or its successor standard ANSI/APSP-16.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide,
or full ow) valve position with the pump running.
WARNING
Jandy Pro Series Pumps are powered by a high-voltage electric motor and must be installed by a
licensed or certiîš¿ed electrician or a qualiîš¿ed swimming pool service technician.
WARNING
Due to the potential risk of îš¿re, electric shock, or injuries to persons, Jandy Pro Series Pumps must be
installed in accordance with the National Electrical Code ® (NEC®), all local electrical and safety codes, and
the Occupational Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National
Fire Protection Association, 470 Atlantic Ave., Boston, MA 02210, or from your local government inspection
agency.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property damage.
WARNING
• Do not connect system to an unregulated city water system or other external source of pressurized
water producing pressures greater than 35 PSI.
• Trapped air in the system can cause the lter lid to be blown off, which can result in death, serious
personal injury, or property damage. Be sure all air is out of the system before operating.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a branch
circuit that is protected by a ground-fault circuit-interrupter (GFCI). Contact a qualiîš¿ed electrician if you
cannot verify that the circuit is protected by a GFCI. Make sure such a GFCI should be provided by
the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI
should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate
in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button
being pushed, a ground current is owing, indicating the possibility of electrical shock. Do not use the
device. Disconnect the device and have the problem corrected by a qualiîš¿ed service representative
before using.
Page 3
ENGLISH
Jandy
®
Pro Series ePumpâ„¢ Series Pump | Installation and Operation Manual


Product specificaties

Merk: JANDY
Categorie: Pomp
Model: VSSHP220AUT

Heb je hulp nodig?

Als je hulp nodig hebt met JANDY VSSHP220AUT stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp JANDY

Handleiding Pomp

Nieuwste handleidingen voor Pomp

Sauermann

Sauermann Omega Handleiding

13 November 2024
Sauermann

Sauermann Delta Handleiding

12 November 2024
Testo

Testo 565i Handleiding

12 November 2024
Simpson

Simpson SCP71008 Handleiding

11 November 2024
MSW

MSW -OP-56-DC Handleiding

5 November 2024
MSW

MSW -FM-N-53 Handleiding

4 November 2024
MSW

MSW -AOP40S Handleiding

15 Oktober 2024
MSW

MSW -MN34M Handleiding

15 Oktober 2024
MSW

MSW -MN34 Handleiding

15 Oktober 2024