JANDY iQPUMP01 Handleiding
Lees hieronder de đ handleiding in het Nederlandse voor JANDY iQPUMP01 (6 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 54 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/6
iQPUMP01
Pump Interface
Quick Start Guide
Control Panel
Auto
Quick Clean
OFF
SVC
Timed Stop
Timed Run
LAN
WANWi-Fi to Phone
iQPUMP01 Interface
This Quick Start Guide is to help you quickly install your
system. Be sure to read all WARNINGS before installation
WARNING
To prevent risk of electrical shock which can result in severe injury or death, ENSURE that the
iQPUMP01 and Pump are OFF and power to the pump is disconnected before proceeding with
installation.
WARNING
To reduce the risk of electric shock, fire or injury, service should only be attempted by a qualified pool
service professional.
This button controls the operational mode of the pump. Push
the button to toggle between Auto and Quick Clean mode. Auto
operates the pump with the settings designated by the app. Quick
Clean will override normal operation and run the pump for 30*
minutes at 3,450* RPM.
This button is used to activate or manually end a direct Wi-Fi to
Phone connection. When ON, you can connect your smart device
directly to the iQPUMP01. When OFF, the iQPUMP01 will attempt to
connect to the pool ownerâs router / internet connection.
* Factory default settings - these settings can be changed in the app.
This button controls the Service Modes for the pump. Timed Stop
will keep the pump OFF for 3* hours. Timed Run turns the pump
ON to run for 3* hours at 2,750* RPM.
Helpful Hints
Invite Codes are used to allow access for other users to control the
iQPUMP01 from their own iAquaLink app
Global Pump Settings: min & max speeds, freeze protect, and other
modes such as Quick Clean, Timed Run, and Timed Stop, are only available
when directly connected to the iQPUMP01 via a connection.Wi-Fi to Phone
Master Users are, in most cases, the pool owner. A Master User can
send invitations to other iAquaLink app users to allow them to control
the pump. To claim Master User of the pump, you must be connected to
the iQPUMP01 via a Wi-Fi to Phone connection. To create or send invite
codes, the master user and the iQPUMP01 must both be connected to the
internet. After claiming âMaster Userâ, end the âWi-Fi to Phoneâ session
by pressing the button to turn the âWi-Fi to Phoneâ LED off. Also ensure
the WEB (or WAN) LED is on before creating or sending an invite code.
Wi-Fi to Phone is technology inside the iQPUMP that transmits a wireless
signal directly to a Wi-Fi enabled device without using an internet
connection. The signal is activated when the Wi-Fi to phone button is
pushed. It will time out after 15 minutes of inactivity or it can also be
manualy deactivated by pushing the Wi-Fi to Phone button while it is on.
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualiïŹ ed in pool equipment by the jurisdiction in which the product will be installed where such state or
local requirements exist, the maintainer must be a professional with sufïŹ cient experience in pool equipment
installation and maintenance so that all of the instructions in this manual can be followed exactly. Before
installing this product, read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage, personal injury, or death.
Improper installation and/or operation will void the warranty. Improper installation and/or operation can create
unwanted electrical hazard which can cause serious injury, property damage, or death. Turn off all circuit
breakers required in order to prevent the possibility of electric shock.
www.ZodiacPoolSystems.com
USA: 1-800-822-7933 | CANADA: 1-888-647-4004 | AUSTRALIA: 1800-688-552
Inviting Other Users
The iQPUMP01 allows user to be the âMaster User.â The Master User can send one
invitations to other iAquaLinkâą users, granting other iAquaLink account holders to
control your pump. In general, only the pool owner should be the Master User.
5.1 In the settings menu, the Master User (only) has the ability to âCreate Invite
Codeâ.
NOTE: If the âCreate Invite Codeâ button is not in the settings menu, then you are
not recognized as the âMaster Userâ. To become the Master User, connect
directly to the iQPUMP01, then proceed to the settings menu, click the
Claim Master User button, and follow the on-screen directions to become
the Master User.
5.2 Write down the code displayed or click on the code to copy the code to the
clipboard of your device.
5.3 Paste the invite code into an email or text message to the individuals that
you would like to have access to the pump.
5.4 In order for invitees to utilize the code, they will ïŹ rst need to download the
iAquaLink app. After logging in or creating a new account, use the invite
code to add the device by pressing the + or ( ) from the âMy Systemsâ
screen.
5
ZODIAC Âź is a registered trademark of Zodiac International, S.A.S.U., used under license.
All trademarks referenced herein are the property of their respective owners.
©2015 Zodiac Pool Systems, Inc. H0509400 Rev E
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
Zodiac Pool Systems Canada, Inc.
2115 South Service Road West, Unit 3 Oakville (ON) L6L 5W2
+ 1 (888) 647-4004 | www.ZodiacPoolSystems.ca
Before Installation
1.1 Before heading to the job site, install the latest version of the iAquaLinkâą app
from the AppleÂź App StoreÂź or from Google PlayÂź. The app is required to
install the iQPUMP01. Internet access will be needed if you want to connect
the iQPUMP01 to the internet, however it is not required to operate the pump.
1.2 Using the newest version of the iAqualink app installed on your mobile device,
log in to your account, or create a new account following the
on-screen instructions.
Wiring the iQPUMP01 Interface
Mount the iQPUMP01 Interface, using the two (2) screws provided, as high as
possible, and a minimum of 10ft. (3m) from any electric motor. Always mount the
device with the antenna on the right side, pointing up towards the sky.
2.1 Remove power from the pump by turning OFF any breaker which may supply
power to the pump.
2.2 Remove the motor drive service cover.
2.3 Feed the cable from the iQPUMP01 through the RS485 cable ïŹ tting on the
pump and connect to the red RS485 connector by attaching the wires as
follows: 1-red, 2-black, 3-yellow, and 4-green.
2.4 Tighten the RS485 Cable Fitting to secure the cable. Make sure that no other
RS485 connections exist. The iQPUMP01 must be the only connected device.
2.5 Slide DIP switches 1 and 2 UP, so they are in the ON position and slide
switches 3 and 4 DOWN, so they are in the OFF position. If you have a
5-position switch, the 5th switch should be in the ON position.
2.6
Plug the RS-485 connector into the pump and reattach the motor drive service
cover.
2.7 Restore power to the pump.
Connecting the iQPUMP01 to the Internet
Connecting the pump to the internet is highly recommended, but not required
to install the iQPUMP01, or ensure daily scheduled operation. Connecting the
iQPUMP01 to the Internet allows anytime, anywhere remote control of the pump.
4.1 If you want to be able to control the pump through the Internet,
click the âAdd to My Systemsâ button.
4.2 From the Pump Management screen, touch Settings ( for
Android users). From the settings screen select the âWi-Fi
Settingsâ button. Select the pool ownerâs Wi-Fi network and
enter the network password.
4.3 Push the âWi-Fi to Phoneâ button on the iQPUMP01. Ensure the
âWi-Fi to Phoneâ LED turns off.
4.4 After a few seconds the orange LAN LED will illuminate
indicating connection to the router. Moments later, the green
WAN (or WEB) LED light will illuminate, indicating connection
to the Internet and the iAquaLink server.
4.5 Now that the iQPUMP01 is connected to the Internet, you can
reconnect to the pump through the Web. From the menu, go
to My Devices, then select the pump named VSPUMP-_ _ _.
Rename the pump from the settings screen. This step can only
be done when connected through the Web. You are now ready
to create invites for other users to have basic acess to control
the pump.
NOTE: You can only create invites when you are the master
user. See step 3.7 and section 5 to claim master user.
iQPUMP01 Setup Using Wi-Fi to Phone
After restoring power to the pump, the Auto LED on the iQPUMP01 should turn on.
3.1 Log in to your iAqualink app on your smart device.
3.2 From the iAquaLink app menu, select âMy Systemsâ, then
âConnect Using Wi-Fi to Phoneâ.
3.3 Push the âWi-Fi to Phoneâ button on the iQPUMP01. ConïŹ rm
that the âWi-Fi to Phoneâ LED is illuminated on the iQPUMP01.
3.4 Go to Wi-Fi settings on your mobile device and select the
Wi-Fi network named âVSPump -_ _ _â. The last 3 digits of
the network name will be the same as the last 3 digits of the
iQPUMP01 device number (found on the white label on the side
of the iQPUMP01)
3.5 Return to the iAquaLink app. The app will say âSearching...â
and in a few moments will switch to the Pump Management
screen.
1
2
4
3
4-Position
DIP Switch 5
D
Power Wiring
Ports
Motor Drive
Service Cover
2 - BLACK
3 - YELLOW
1 - RED
4 - GREEN
RS485
Cable (22 AWG)
WARNING
To prevent risk of electrical shock which can result in severe injury or death, ENSURE that the
iQPUMP01 and Pump are OFF and power to the pump is disconnected before proceeding with
installation.
WARNING
Installing the iQPUMP01 requires internal access to the pump drive containing high voltage wiring.
To
reduce the risk of electric shock, fire or injury,
only licensed electricians, or a qualified pool professional
should attempt this installation.
WARNING
To reduce the risk of electric shock, fire or injury,
the pump must be plumbed in and bonded. All high
voltage wiring must be completed before installing the iQPUMP01.
3.6 From the Pump Management screen, you can stop the pump,
begin a custom speed cycle, or return the pump to âAutoâ
mode. If these options are not available, the iQPUMP01 may be
in a service mode. A service mode can be ended by pushing the
physical Auto / Quick Clean button on the iQPUMP01.
3.7 From the Pump Management Screen, touch âSettingsâ ( for
Android users) button to set up the time zone, edit schedules,
min & max speeds, freeze protect, and all other modes such as
Quick Clean, Timed Run, Timed Stop, etc. Push âClaim Master
Userâ to become the Master User of the pump. As the Master
User, you can create invite codes to allow others to control the
pump.
iQPUMP01
Interface de la pompe
Guide de démarrage rapide
Panneau de commande
Auto
Quick Clean
OFF
SVC
Timed Stop
Timed Run
LAN
WANWi-Fi to Phone
iQPUMP01 Interface
Ce guide de dĂ©marrage rapide facilite lâinstallation du systĂšme.
Assurez-vous de lire tous les AVERTISSEMENTS avant lâinstallation
AVERTISSEMENT
Pour éviter tout risque de décharge électrique pouvant entraßner des blessures graves, voire
mortelles, assurez-vous que lâinterface iQPUMP01 et la pompe sont hors tension et que
lâalimentation de la pompe est dĂ©branchĂ©e avant dâeffectuer lâinstallation .
AVERTISSEMENT
Pour rĂ©duire les risques de dĂ©charge Ă©lectrique, dâincendie ou dâaccidents, lâentretien doit ĂȘtre fait
uniquement par un technicien qualifiĂ©, spĂ©cialisĂ© dans lâentretien des piscines.
Ce bouton commande le mode de fonctionnement de la pompe. Appuyer sur
le bouton pour passer du mode Auto (automatique) Ă celui de Quick Clean
(nettoyage rapide). Le mode Auto (automatique) commande le fonctionnement
de la pompe Ă lâaide des paramĂštres dĂ©signĂ©s par lâapplication. Le mode Quick
Clean (nettoyage rapide) annule le fonctionnement normal et fait fonctionner la
pompe pendant 30* minutes Ă 3 450* T/M.
Ce bouton est utilisé pour activer ou interrompre manuellement la connexion
Wi-Fi directe Ă un tĂ©lĂ©phone. Au moment de la mise sous tension, lâappareil
intelligent peut ĂȘtre connectĂ© directement Ă lâinterface iQPUMP01. Au moment
de la mise hors tension, lâinterface iQPUMP01 essaiera de se connecter au
routeur du propriétaire de la piscine/à la connexion Internet.
* Les rĂ©glages dâusine par dĂ©faut â ces paramĂštres peuvent ĂȘtre modiïŹ Ă©s depuis lâapplication.
Ce bouton commande les modes dâentretien de la pompe. La fonctionnalitĂ©
Timed Stop (temps dâarrĂȘt) maintiendra la pompe hors tension pendant
3* heures. La fonctionnalité Timed Run (temps de fonctionnement) fait
fonctionner la pompe pendant 3* heures Ă 2 750* T/M.
Conseils pratiques
Les codes dâinvitation sont utilisĂ©s pour permettre Ă dâautres utilisateurs de
commander lâinterface iQPUMP01 depuis leur propre application iAquaLink.
ParamÚtres généraux de la pompe : les modes vitesses min et max, protection
contre le gel et autres comme le nettoyage rapide, le temps de fonctionnement et le
temps dâarrĂȘt ne sont disponibles que lorsque la pompe est connectĂ©e directement
Ă lâinterface iQPUMP01 par le biais dâune connexion Wi-Fi Ă tĂ©lĂ©phone.
Les utilisateurs principaux sont, dans la plupart des cas, les propriétaires de
la piscine. Un utilisateur principal peut transmettre une invitation Ă dâautres
utilisateurs de lâapplication iAquaLink pour leur permettre de commander
la pompe. Pour rĂ©clamer les droits dâUtilisateur principal de la pompe, vous
devez ĂȘtre connectĂ© Ă lâinterface iQPUMP01 par le biais dâune connexion Wi-
Fi Ă tĂ©lĂ©phone. Pour crĂ©er ou transmettre les codes dâinvitation, lâappareil de
lâUtilisateur principal et lâinterface iQPUMP01 doivent ĂȘtre tous deux connectĂ©s Ă
lâInternet. AprĂšs la rĂ©clamation des droits dâ« Utilisateur principal », interrompre
la session de connexion « Wi-Fi to Phone » (Wi-Fi à téléphone) en appuyant
sur le bouton pour éteindre la DEL « Wi-Fi to Phone » (Wi-Fi à téléphone).
Sâassurer Ă©galement que la DEL WEB (ou WAN) est allumĂ©e avant de crĂ©er ou de
transmettre un code dâinvitation.
La fonctionnalité (Wi-Fi à téléphone) est une technologie à « Wi-Fi to Phone »
lâintĂ©rieur de lâinterface iQPUMP qui transmet un signal sans ïŹ l directement Ă
un appareil Wi-Fi compatible sans utiliser une connexion Internet. Le signal est
activé lorsque le bouton Wi-Fi to Phone (Wi-Fi à téléphone) est enfoncé. Il sera
interrompu aprĂšs 15 minutes dâinactivitĂ© ou il peut Ă©galement ĂȘtre dĂ©sactivĂ©
manuellement en appuyant sur le bouton Wi-Fi to Phone (Wi-Fi à téléphone) alors
quâil est activĂ©. AVERTISSEMENT
POUR VOTRE SĂCURITĂ â Ce produit doit ĂȘtre installĂ© et entretenu par un entrepreneur qui est autorisĂ© et spĂ©cialisĂ©
dans lâentretien dâĂ©quipement de piscine par le territoire de compĂ©tence dans lequel le produit sera installĂ© oĂč de telles
exigences dâĂtat ou locales existent. Le spĂ©cialiste dans lâentretien dâĂ©quipement de piscine doit avoir une expĂ©rience
sufïŹ sante en matiĂšre dâinstallation et dâentretien dâĂ©quipement de piscine de sorte que toutes les instructions dĂ©crites
dans le prĂ©sent manuel puissent ĂȘtre suivies Ă la lettre. Avant dâinstaller ce produit, priĂšre de lire et de respecter toutes
les consignes de mise en garde et les instructions comprises avec ce produit. Le non-respect des mises en garde et
des instructions pourrait causer des dommages matĂ©riels, des blessures ou mĂȘme la mort. Lâinstallation ou lâutilisation
inappropriĂ©e annulera la garantie. Lâinstallation ou lâutilisation inappropriĂ©e peuvent crĂ©er un danger Ă©lectrique
indésirable, lequel peut entraßner des blessures graves, des dommages matériels ou la mort. Désactiver tous les
disjoncteurs pour éviter la possibilité de décharge électrique.
www.ZodiacPoolSystems.com
Ă.-U. : +1-800-822-7933 | CANADA : +1-888-647-4004 | AUSTRALIE : +1-800-688-552
Invitation Ă dâautres utilisateurs
Lâinterface iQPUMP01 permet Ă utilisateur dâĂȘtre lâ« Utilisateur principal ». LâUtilisateur un
principal peut transmettre une invitation Ă dâautres utilisateurs de lâiAquaLinkâą, leur
accordant lâaccĂšs Ă lâiAquaLink pour commander la pompe. En gĂ©nĂ©ral, seul le propriĂ©taire
de la piscine doit ĂȘtre lâUtilisateur principal.
5.1 Depuis le menu Settings (paramĂštres), seul lâUtilisateur principal peut crĂ©er un
code dâinvitation.
REMARQUE : Si le bouton « Create Invite Code » (crĂ©er un code dâinvitation) nâest pas dans
le menu Settings (paramĂštres), vous nâĂȘtes pas reconnu comme un Utilisateur principal.
Pour devenir lâUtilisateur principal, connectez-vous directement Ă lâinterface iQPUMP01,
puis passez au menu des paramÚtres, cliquez sur le bouton Claim Master User (réclamer
les droits dâUtilisateur principal) et suivez les instructions depuis lâĂ©cran pour devenir
lâUtilisateur principal.
5.2 Notez le code afïŹ chĂ© ou cliquez sur le code pour copier le code dans le presse-
papiers de votre appareil.
5.3 Collez le code dâinvitation dans un courriel ou textez le message aux personnes Ă
qui vous souhaitez donner lâaccĂšs Ă la pompe.
5.4 Pour que les invitĂ©s puissent utiliser le code, ils doivent tout dâabord tĂ©lĂ©charger
lâapplication iAquaLink. AprĂšs une ouverture de session ou la crĂ©ation dâun nouveau
compte, utilisez le code dâinvitation pour ajouter lâappareil en appuyant sur les
touches + ou ( ) depuis lâĂ©cran « My Systems » (mes systĂšmes).
5
ZODIAC Ÿ est une marque déposée de Zodiac International, S.A.S.U., utilisée sous licence.
Toutes les marques de commerce mentionnées dans le présent document sont la propriété de leurs propriétaires respectifs.
© 2015 Zodiac Pool Systems, Inc. H0509500 Rév. C
Zodiac Pool Systems, Inc.
2620, Commerce Way, Vista, CA 92081
+1-800-822-7933 | www.ZodiacPoolSystems.com
Zodiac Pool Systems Canada, Inc.
2115, South Service Road West, Unité 3 Oakville, ON L6L 5W2
+ 1-888-647-4004 | www.ZodiacPoolSystems.ca
Product specificaties
Merk: | JANDY |
Categorie: | Pomp |
Model: | iQPUMP01 |
Heb je hulp nodig?
Als je hulp nodig hebt met JANDY iQPUMP01 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp JANDY
8 Juli 2023
7 Juli 2023
6 Juli 2023
6 Juli 2023
5 Juli 2023
2 Juli 2023
1 Juli 2023
29 Juni 2023
29 Juni 2023
29 Juni 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Gardenline
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Technaxx
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Aerotec
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp ZĂ©fal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
4 December 2024
4 December 2024
30 November 2024
30 November 2024
23 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024