BPU 0SATA 3 Hard Drive Cage-35 .5”
User’s Manual
Specicaon:
Order Informaon:
Hot Swap
5x3.5”HDD
Cooling Fan
1x80mm
Standard Drive Bays
5.25” Drive: 3
Dimension (W x H x D)
5.75 x 4.96 x 8.11 inches
Material
Aluminum Design with Conducve Dissipaon
Grooves
HDD Interface
SATA / SAS
Weight
4bs
Cable
SATA Cable Included (5pcs)
Model Number:
Color:
UPC Code:
BPU 0SATA BLACK -35 -
BPU SATA RED -350 -
BPU SATA BLUE -350 -
BPU SATA SILVER -350 -
BPU 350SATA BPL- -
(lockable handle)
Black
Red
Blue
Silver
Plasc
846813022606
846813000604
846813000598
846813000611
846813016087
Introducon:
Create more space for hard drive with hot swap capability, by using the BPU- -
350SATA HDD cage series that supports RAID 1/0/1+0/5 conguraon for high
performing data recovery or redundancy applicaon. Its aluminum construcon
translates into lighter system weight and better heat dissipaon. The 80mm fan
also help keeps hard drives at maximum performance temperature.
Features:
Aluminum Frame, Aluminum cover
Interface: Support SAS-I and SAS-II, SATA-I, SATA-II, SATA-III
High performance transfer rate: up to 6.0 GB/s for SAS & SATA hard drives
Plug & play, hot swappable
SATA 15Pin & 4Pin Power connectors
LED for P/S, HDD access, Fan sensor & Buzzer
Power Control Switch
3-stage temperature alarm sengs & reset switch for buzzer alarm
8cm cooling fan X1
Dim: 8.11(L) X 5.75(W) X 4.96(H) inch
Patent products with advanced structure design
Patent balance handle-No skew in/out problem & avoid the abrasion during
connecon
Precisely connecon on connector
Hardware Informaon: Front View
D 1 ~ D 5:- - Power Switch & HDD LED. Power On: LED indicates Blue. Purple color blinking
for HDD access.
D 6-: Reset Switch & Overheat LED. Power On: LED indicates Blue. Overheat (default 55º
C): LED indicate Red and buzzer alarms. Press the Reset Switch (D 6) to stop the alarm -
for 3 minutes.
D 7:- Fan senor LED. Fan On: LED indicates Blue. Fan O: LED indicates Red and buzzer
alarms. Press the Reset Switch (D 6) to stop the alarm. -
(If you want to switch o the “Alarm funcon”, press the Reset Switch (D 6) for more -
than 6 seconds unl 3 beeps comes out, then the “Alarm funcon” stopped.)
BPU 0SATA-35
BPU 0SATA-35
iStarUSA – Powered by iStarUSA Group
727 Phillips Drive
City of Industry, CA 91748
Tel: (888) 989 1189-
Email: sales@istarusa.com
BPU 350SATA-
Hardware Informaon: Rear View
POWER1: 4pin Power connector.
POWER2: 15pin Serial ATA Power connector.
(may use any two type of power connector)
HD1 HD5— : 7pin Serial ATA Signal connector
JP1: Temperature seng jumper (default: 55º C)
J5: FAN RPM Switch: HIGH & AUTO Oponal.
(Every me when you turn on the power, the fan runs for 10 seconds and then
stop. It will run again when temperature reaches º C40 .)
J6: HD LED Switch (default: Enable)
JP1 Jumper pin seng:
Quick Installaon Procedure:
1. Open up the handle bar from the tray; take out the HD trays from the HD
cage.
2. Secure all screws to the HD aached with HD tray.
3. Place the hard drive tray(s) with HD installed, back into the cage unit.
4. Push the handling bar into closed posion.
5. Connect all necessary data and power cable onto the rear end of cage
unit.
(Make sure that the date cables connected to the motherboard side as
well).
6. Turn on the Power of your computer and wait unl Operang System
nish loading up.
7. Turn on all necessary HD1~HD4 Power Buon(s) for each Hard Drive
installed.
Note:
For steps 6 if the operang system installed with a HD inside of HD cage, please make -
sure you do turn on the Power from the cage switches D1/D2/D3/D4 or D5.
For oponal RAID Conguraon & Setup procedure, please follow the user manual
instrucons from your SAS/SATA Controller Card or Motherboard.
Accessories:
5 SATA cables
Screws
2.5” or 3.5” Hard Drive Disk to the trays Installaon:
1. Insert 2.5” or 3.5” Hard Drive into the
HDD Tray from the cage.
2. Use the provided screws and fasten HD
into highlighted 2.5” or 3.5” holes to the
cage trays.
3. Make sure Secure with screw holes from
the Boom of 2.5” or 3.5” Hard Drive’s.
4. Aer the screw installaon, slide the HDD
Tray back to the HDD Canister Base.
5. Next, follow the Quick Installaon in next
page for the rest of the Setup.
Oponal Accessories:
iStarUSAcare:
We will help you navigate our website to nd the informaon that
you need. Go to www.istarusa.com, and click on live chat bubble
above the Search Bar
Our technicians are standing by to take your quesons. Visit
hp://istarusa.com/support/ , and you will receive a technical
support cket to help track your requests from the beginning to the
end. Or you can contact us @ 888 989 1189- -
FCC and CE Radiation Norm
FCC
This equipment has been tested and found to comply with limits for Class B digital device pursuant to Part of Federal Communications 15
Commission (FCC) rules.
CE
This equipment has been tested and found to comply with the limits of the European Council Directive on the approximation of the law of the member
states relating to electromagnetic compatibility (89/336/EEC) according to EN 55022 Class B.
FCC and CE Compliance Statement
These limits are designed to provide reasonable protection against frequency interference in residential installation. This equipment generates uses
and can radiate radio frequency energy, and if not installed or used in accordance with the instructions may cause harmful interference to radio
communication. However, there is no guarantee that interference will not occur in television reception, which can be determined by turning the
equipment off and on. The user is encouraged to try and correct the interference by one or more of the following measures: Reorient or relocate the
receiving antenna, Increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from
that to which the receiver is connected to.
CAUTION!
The Federal Communications Commission warns the user that changes or modifications to the unit not expressly approved by the party responsible
for the compliance could void the user’s authority to operate the equipment.
HD Trays
Model Number
UPC Code:
Black
Red
Blue
Silver
Plasc
BPU-HSTRAY BLACK-
BPU-HSTRAY-RED
BPU-HSTRAY BLUE-
BPU-HSTRAY SILVER-
BPU-HSTRAY
846813000635
846813000659
846813000642
846813000673
846813000628
BPU 0ATA-35
BPU 0SATA-35
BPU 0SATA-35 BPU 0SATA-35
3.5” HD Screw Holes
HD Tray: Bottom View
2.5” HD
Screw Holes
3.5” HD Screw Holes
Product specificaties
Merk: | IStarUSA |
Categorie: | Disk array |
Model: | BPU-350SATA-KL |
Kleur van het product: | Zwart |
Breedte: | 146 mm |
Diepte: | 209.5 mm |
Hoogte: | 126 mm |
Meegeleverde kabels: | SATA |
Duurzaamheidscertificaten: | RoHS |
Aantal ventilatoren: | 1 ventilator(en) |
Intern: | Ja |
Type behuizing: | Desktop |
Opslagdrives geïnstalleerd: | Nee |
Geïnstalleerde opslag-drive: | Nee |
Totale geïnstalleerde opslagcapaciteit: | - TB |
Maximaal ondersteunde opslagcapaciteit: | - TB |
Opslag schijf-interface: | Serial ATA, Serial ATA II, Serial ATA III |
Opslag schijfgrootte: | 2.5/3.5 " |
Soorten RAID: | JBOD |
Overdrachtssnelheid: | 6 Gbit/s |
Aantal storage drives ondersteund: | 5 |
Hot-swap drive bays: | Ja |
Ondersteunde types opslag-drives: | HDD & SSD |
Host-poorten: | 5 |
SATA-hostpoort: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met IStarUSA BPU-350SATA-KL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Disk array IStarUSA
16 April 2024
16 April 2024
16 April 2024
16 April 2024
16 April 2024
16 April 2024
16 April 2024
16 April 2024
16 April 2024
16 April 2024
Handleiding Disk array
- Disk array HP
- Disk array Buffalo
- Disk array D-Link
- Disk array Dell
- Disk array Fantec
- Disk array Fujitsu
- Disk array Hitachi
- Disk array Icy Box
- Disk array LaCie
- Disk array Netgear
- Disk array QNAP
- Disk array Seagate
- Disk array Sharkoon
- Disk array Synology
- Disk array Western Digital
- Disk array Vantec
- Disk array IoSafe
- Disk array SilverStone
- Disk array AIC
- Disk array Addonics
- Disk array Intel
- Disk array Supermicro
- Disk array G-Technology
- Disk array Tandberg Data
- Disk array Areca
- Disk array Icy Dock
- Disk array HGST
- Disk array Sonnet
- Disk array CRU
- Disk array Promise Technology
- Disk array OWC
- Disk array Raidsonic
- Disk array Rocstor
- Disk array Infortrend
- Disk array Glyph
- Disk array IDIS
- Disk array Enhance
Nieuwste handleidingen voor Disk array
18 November 2024
16 November 2024
25 Juli 2024
25 Juli 2024
25 April 2024
25 April 2024
25 April 2024
8 April 2024
25 Maart 2024
25 Maart 2024