Operating instructions
Diffuse reflection sensor
with background suppression
OGH
701166 / 03 09 / 2005
UK
UK
UK
UK
UK
2
Function and features
The diffuse reflection sensor detects objects and materials without contact and
indicates their presence by a switched signal.
Range (r): see type label (value referred to white paper 200mm x 200mm).
Electrical connection
Isolate power, then connect the unit (see page 5 or type label).
Core colours (for sensors with cable connection): BN = brown, BU = blue, BK =
black.
Programming of the output function (light-on or dark-on) by wiring (see page 5 or
type label).
Installation
21
Pushbutton
LEDs red, green, yellow
Align the photocell and fasten it to a mounting bracket.
Maximum range is only possible with precise alignment.
1:
2:
Isolate power, then connect the unit (see page 5 or type label).
3
UK
Setting of the sensitivity with stationary objects
1
Activate the programming mode of the unit without object.
Press for about 2s until the red LED flashes.
The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
If in addition the red LED is lit, the reflection of the background is too intensive (e.g.
reflecting surface). Angle the unit in the horizontal plane until the red LED goes out.
If you continue with step 3 although the red LED is lit, programming is interrupted.
The unit then passes into the operating mode with the setting being unchanged.
2
Setting without object.
Press once.
The yellow and green LEDs go out for approx. 1s, then flash again alternately.
3
Setting with object.
Press once.
The yellow and green LEDs go out for approx. 1s, then the green LED is on.
The unit is in the operating mode.
Programming is only possible if you keep to this order (first background, then
object).


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: OG5054

Heb je hulp nodig?

Als je hulp nodig hebt met IFM OG5054 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM MK5344 Handleiding

15 November 2024
IFM

IFM OL5029 Handleiding

15 November 2024
IFM

IFM EVC284 Handleiding

15 November 2024
IFM

IFM OB5022 Handleiding

15 November 2024
IFM

IFM AL4302 Handleiding

15 November 2024
IFM

IFM AC1006 Handleiding

12 November 2024
IFM

IFM AC1345 Handleiding

12 November 2024
IFM

IFM CR3122 Handleiding

12 November 2024
IFM

IFM DV1531 Handleiding

12 November 2024
IFM

IFM DV1501 Handleiding

12 November 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd