2
Remarks for safe use in hazardous areas
Functions and features
• Use in hazardous areas according to the classification
II 1G / 2G
(group II, category 1G / 2G, apparatus for gas atmosphere).
The requirements of the standards EN 60079-0:2009, EN 60079-11:2012,
EN 60079-26:2007+Corr.2009 are met.
EC type examination certificate
PTB 01 ATEX 2191
• Use in hazardous areas according to the classification
II 1D
(group II, category 1D, apparatus for dust atmosphere).
The requirements of the standards IEC 60079-0:2011 and EN 60079-11:2012 are met.
EC type examination certificate
BVS 04 ATEX E153
The requirements of the standards IEC 60079-0:2011+Corr.2012+Corr.2013 and
IEC 60079-11:2011+Corr.2012 are met.
IECEx certificate
IECEx BVS 06.0003
• Marking
ATEX classification Marking Ta in °C Applies to type
II 1G Ex ia IIC T6 Ga
Ta -20...70 °C
NT****
NE****
NF****
II 1D Ex ia IIIC T 90°C Da
II 1G Ex ia IIC T5 Ga
Ta -20...80 °C
II 1D Ex ia IIIC T 100°C Da
II 1G Ex ia IIB T6 Ga
Ta -20...70 °C
NG****
NI****
NN****
NS****
II 2G Ex ia IIC T6 Gb
II 1D Ex ia IIIC T 90°C Da
II 1G Ex ia IIB T5 Ga
Ta -20...80 °C
II 2G Ex ia IIC T5 Gb
II 1D Ex ia IIIC T100°C Da
3
UK
Installation / Set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of types of protection, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (see "Marking" above and marking on the unit) is suitable
for the application.
• Connection only to intrinsically safe certified circuits or evaluation amplifiers which do not
exceed the following maximum values of the units:
Ui = 15 V, Ii = 50 mA, Pi = 120 mW
• Permissible operating temperature of the application (referred to the maximum permissible
power of 120 mW):
according to marking
• Maximum effective internal inductance (Li) and capacitance (Ci):
Article no. Internal inductance (total) in HμInternal capacitance (total)
in nF
NE5001 70 80
NE5012 87 83
NF5001 340 140
NF5002 340 140
NF5003 130 140
NF5004 130 140
NF5008 134 141
NF5010 134 141
NF5012 344 141
NF5023 147 143
NF5030 134 141
NG5001 45 145
NG5002 45 145
NG5003 50 155
NG5004 50 155
NG5010 58 157
NG5011 53 147
NG5016 62 157
NG5019 49 146
NG5021 54 156


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: NG5004

Heb je hulp nodig?

Als je hulp nodig hebt met IFM NG5004 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM MK5344 Handleiding

15 November 2024
IFM

IFM OL5029 Handleiding

15 November 2024
IFM

IFM EVC284 Handleiding

15 November 2024
IFM

IFM OB5022 Handleiding

15 November 2024
IFM

IFM AL4302 Handleiding

15 November 2024
IFM

IFM AC1006 Handleiding

12 November 2024
IFM

IFM AC1345 Handleiding

12 November 2024
IFM

IFM CR3122 Handleiding

12 November 2024
IFM

IFM DV1531 Handleiding

12 November 2024
IFM

IFM DV1501 Handleiding

12 November 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd