IFM JD2120 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor IFM JD2120 (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 29 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
Installation instructions
Inclination sensor JD
80294704/00 05/2020
1 Preliminary note
You will find the device manual, technical data, approvals, accessories and further
information at www.ifm.com.
2 Safety instructions
The device described is a subcomponent for integration into a system.
- The manufacturer is responsible for the safety of the system.
- The system manufacturer undertakes to perform a risk assessment and to
create a documentation in accordance with legal and normative requirements
to be provided to the operator and user of the system. This documentation
must contain all necessary information and safety instructions for the operator,
the user and, if applicable, for any service personnel authorised by the
manufacturer of the system.
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
Only use the product for its intended purpose (→ 3 Function and features).
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, programming, configuration, operation
and maintenance of the product must be carried out by personnel qualified and
authorised for the respective activity.
Protect units and cables against damage.
3 Functions and features
Dynamic MEMS inclinometers sense and measure the angle of tilt (inclination/
slope/elevation) of an object.
JD1xxx: 1-axis sensor with angular range 0...360° (vertical installation).
JD2xxx: 2-axis sensor with angular range ±90° (horizontal installation).
4 Installation
Choose a level mounting surface.
Fix the unit using 4 screws, tightening torque 1.5...2.5 Nm.
Recommendation:
M6 screws or ¼” UNC screws
Adjust M12 connectors precisely and screw them fully into the unit, tightening
torque 1.5 Nm.
5 Electrical connection
The inclinometer is connected via a 5-pin M12 connector.
Pin configuration
4
2 1
3
5
1: CAN _GND
2: Supply voltage 24 V DC (+U
B
)
3: GND
4: CAN_H High bus cable
5: CAN_L Low bus cable
M12 connector CAN-In
3
1 2
4
5
1: CAN _GND
2: Supply voltage 24 V DC (+U
B
)
3: GND
4: CAN_H High bus cable
5: CAN_L Low bus cable
M12 socket CAN-Out
5.1 Bus termination
The sensor has a terminating resistor that can be enabled (120 Ω). Depending on
the interface, this resistor can be activated via the software (default: deactivated).


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: JD2120

Heb je hulp nodig?

Als je hulp nodig hebt met IFM JD2120 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM MK5344 Handleiding

15 November 2024
IFM

IFM OL5029 Handleiding

15 November 2024
IFM

IFM EVC284 Handleiding

15 November 2024
IFM

IFM OB5022 Handleiding

15 November 2024
IFM

IFM AL4302 Handleiding

15 November 2024
IFM

IFM AC1006 Handleiding

12 November 2024
IFM

IFM AC1345 Handleiding

12 November 2024
IFM

IFM CR3122 Handleiding

12 November 2024
IFM

IFM DV1531 Handleiding

12 November 2024
IFM

IFM DV1501 Handleiding

12 November 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd