Installation Instructions
Inductive sensor
IME non flush
704288 / 00 09 / 2007
UK
UK
UK
UK
UK
2
Function and features
This sensor detects metals without contact and indicates their presence by provi-
ding a switched signal. The nominal sensing range (Sn) can be seen in the type
designation on the type label on the unit; operating distance (Sa) 0 ... 0,81 x Sn;
(values based on standard measurement with mild steel; a shorter sensing range
for other metals).
Installation
Screw the proximity switch to a firm
base. If there is high mechanical stress,
ensure that it cannot work loose (fig. 1).
Non-flush installation.
Open space in front of the sensing
face when mounted in metal: fig. 2
and 3.
Minimum distance when several
sensors of the same type are
mounted: fig. 4 and 5.
•
•
9mm
3 x Sna2 x a2 x a
8 x Sn
2 x aa a
2 3
4 5
1
3
UK
Electrical connection
Disconnect power before connecting the sensor. Open the sensor (fig. 6);
connect cable in accordance with the instructions on the type label.
Note: insert a miniature fuse according to the technical data sheet, if specified.
Recommendation: check the unit for reliable function after a short cirucit.
Programming of the output function:
Units which are not programmed by means of connections are provided in N.O.
Open the wire link for programming the N.C. function (fig. 7A).
Aufkle er (B)b
sti ker (B)c
a c auto oll nt (B)
7A
Aufkle er (A)b
sti ker (A)c
a c auto oll nt (A)
Alignment of the sensing face
Remove the sensor cube (fig. 7); align sensing face and re-insert the sensor cube.
When the sensor is mounted on a metal surface, the face of the cube marked by a
sticker (A) must point to this metal surface.
When the sensor has been screwed together, position the marking sticker
provided on the outer surface of the sensor unit so that the sensing face is
marked.
Operation
Check the safe functioning of the sensor: The LED is lit when the supply voltage
is applied.
The operation of the sensor is maintenance free. For perfect functioning make
sure that:
the sensing face and the open space are kept free of metal deposits and
foreign bodies, particularly for installation with the sensing face facing upwards.
EMC: The unit conforms to the requirements of EN 60947-5-2.
•
•
6 7


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: IM5038

Heb je hulp nodig?

Als je hulp nodig hebt met IFM IM5038 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM TAD981 Handleiding

26 November 2024
IFM

IFM TAD961 Handleiding

26 November 2024
IFM

IFM TAD091 Handleiding

26 November 2024
IFM

IFM TAD181 Handleiding

26 November 2024
IFM

IFM MK5344 Handleiding

15 November 2024
IFM

IFM OL5029 Handleiding

15 November 2024
IFM

IFM EVC284 Handleiding

15 November 2024
IFM

IFM OB5022 Handleiding

15 November 2024
IFM

IFM AL4302 Handleiding

15 November 2024
IFM

IFM AC1006 Handleiding

12 November 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd