43041-01 09/12/2011
1
Bath Ventilator with Light
Owners Manual
Halcyon
43034-01
20110908
©2011 Hunter Fan Co.
Model
81030
English Español
Página 22
43034-01 09/12/2011
2
W A R N I N G
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy/unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power
unit.
3. DO NOT install this product in a wall. This product is
designed for installation in ceilings up to a 12/12 pitch (45
degrees). Ductwork must point upward.
4. Please read specification label on product for further infor-
mation and requirements.
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and clean the
fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a
soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove
motor plate, find the single tab on the motor plate (located next to the recepta-
cle). Push up rear motor plate tab while pushing out on the side of the housing
or insert a screwdriver into the slot in the housing (next to tab) and twist screw-
driver. Gently vacuum fan, motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN
WATER.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bear-
ings are making excessive or unusual
noises, replace the motor with the exact service motor. You should replace the
impeller at the same time.
W A R N I N GC A U T I O N
1. Use this unit only in a manner intended by the manufacturer. If
you have questions, contact the manufacturer.
2. Before servicing or cleaning the unit, switch power off at ser-
vice panel and lock the service disconnecting means to prevent
power from being switched on accidentally. when the service
disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhausting
of gasses through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer’s guideline and safety standards, such as those published
by the National Fire Prevention Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall(s) or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. Install fan at least 5 feet (1.52 m) above the floor.
10. This unit must be grounded.
11. Unit must not be installed in a ceiling thermally insulated to a value
greater than R40.
!
!!
DISCONNECT ELECTRIC
POWER SUPPLY
AND LOCK OUT
SERVICE PANEL BEFORE
SERVICING UNIT
Do Not Install Above
Or Inside This Area
Cooking
Equipment
Floor
45° 4
COOKING AREA
43034-01 09/12/2011
3
x2
D
E
F
G
H
I
L
M
N
95044-01-000
95029-01-000
77481-01-000
03242-07-133
98037-06-000
74508-03-133
98025-01
75184-01-133
Q
x4
*
*
*
NOTE: Strain relief cable connector
must be installed. Not
Included.
A
B
C
Extra Screws
x2
I
3/8” Cable Connec rto
O
P
J
K
65219
66002-01
77539-01
98255-01
98047-01-199
77521-01
12
E
I
Turn off the power source.
Tools Needed.
Estimated assembly time: 30 to 60 minutes
Before Installation
Check all the parts.
If damaged, call
1-888-830-1326
for replacements.
Included.
Loosen screws.
NOTE: Remove all packing materials before installation.
43034-01 09/12/2011
4
5
4
7
G
8
F
H
E
3
6
Remove the motor/blower from the housing.
Remove the pre-loaded screw tip covers.
Remove the wiring cover screw.
Back out the pre-loaded screw tips until flush
with the side of the housing.
Remove the wiring cover.
Remove packing material.
43034-01 09/12/2011
5
9
E
10
B
C
E
A11
5/8
1/2
A12
Pop out the first wiring access slug. Use second if
needed.
Insert the strain relief into the housing and
secure with the washer.
Position the correct depth mark at the bottom edge of
the joist based on the thickness of your sheetrock.
New Construction attaching to joist
Choose Installation Option
For New Construction - attaching to joist go to step A11, page 5
For New Construction - suspended between joists go to step B11, page 8
For Existing Construction - accessible from above go to step C11, page 11
For Existing Construction - accessible only from below go to step D11,
page15
Screw pre-loaded screws into joist or framing.
43034-01 09/12/2011
6
A
3 nPi
2 nPi
Fan Motor
Light Light
Green
Black
Black
White
Black
Black
White
White Bare Copper
Ground
A14
Main Switch 1 )(AC In
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
A13
A16
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
A15
E
F
G
Install the wiring cover plate. Make sure all
wiring connections are inside the box or under
the wiring cover plate.
Connect wires as shown.
Pull wires through the strain relief.
43034-01 09/12/2011
7
A19
I
A20
Connect wiring from the motor to the wiring cover
plate.
0000
A17
0000
A18
A21
Reinstall the motor by inserting the tabs and pushing
up into position. Make sure the wires are not pinched
between the motor and the housing.
Secure the motor by tightening the 2 screws. Turn on the power source.
Test the motor. If the motor does not run, check the
plug connection.
A22
43034-01 09/12/2011
8
B11
D
E
5/8
1/2
5/8
1/2
B12
1/8" Bit
B14
B15 B16
E
B13
Slide the mounting rails into brackets.
Mark position of screws by using holes as a template.
Insert screws, leaving space between the screw
head and the joist. Screws are not provided.
New Construction suspended between joists
Position the correct depth mark at the bottom edge of
the joist based on the thickness of your sheetrock.
Drill a hole in the center of each outline.
Attach the rails onto the screws.
43034-01 09/12/2011
9
B17 B18
Connect wires as shown.
A
3 nPi
2 nPi
Fan Motor
Light Light
Green
Black
Black
White
Black
Black
White
White Bare Copper
Ground
B19
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
B21
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under the
wiring cover plate.
F
G
B20
Tighten screws. Pull wires through the strain relief.
43034-01 09/12/2011
10
B22
H
Connect wiring from the motor to the wiring cover
plate.
H
B23
Reinstall the motor by inserting the tabs and pushing
up into position. Make sure the wires are not pinched
between the motor and the housing.
B25
Turn on the power source.
ON
OFF
B26
Test the motor. If the motor does not run,
check the plug connection.
B24
I
Secure the motor by tightening the 2 screws.
B27
43034-01 09/12/2011
11
C12
D
E
EXISTING NFA
C11 NO EXISTING NFA
8”
8.5”
5/8
1/2
5/8
1/2
C13 C14
Existing Construction accessible from above
OR
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
motor housing (8”x 8.5”).
Cut out an opening for the housing.
Use the motor housing as a template to mark position.
Slide the mounting rails into brackets.
Position the correct depth mark at the bottom edge of
the joist based on the thickness of your sheetrock.
Mark position of screws by using holes as a template.
43034-01 09/12/2011
12
C15
1/8" Bit
C16
C17
C18
C19 C20
Drill a hole in the center of each outline. Insert screws, leaving space between the screw head
and the joist. Screws are not provided.
Attach the rails onto the screws. Tighten screws.
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may
need to be purchased.
Pull wires through the strain relief.
43034-01 09/12/2011
13
C21
A
3 Pin
2 Pin
Fan Motor
Light Light
Green
Black
Black
White
Black
Black
White
White Bare Copper
Ground
C22
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
C24
H
G
F
C23
Tighten the strain relief screws.
Connect wires as shown.
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under the
wiring cover plate.
Connect wiring from motor the motor
to the wiring cover plate.
43034-01 09/12/2011
14
C25
H
C26
I
C27
ON
OFF
C28
Secure the motor by tightening the 2 screws.
Reinstall the motor by inserting the tabs and pushing
up into position. Make sure the wires are not pinched
between the motor and the housing.
Turn on the power source. Test the motor. If the motor does not run,
check the plug connection.
C29
43034-01 09/12/2011
15
EXISTING NFA
D11
E
D12
D13
2
1
D14
E
D15
Existing Construction accessible only from below
Pull wires through strain relief.
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
motor housing (8”x 8.5”).
Move the housing into position above the ceiling.
Attach existing ducting to duct connector. Tape joints.
If ducting does not fit securely,
an adapter may need to be purchased.
Install the housing flush with the sheetrock and secure
by tightening the pre-loaded screws into the joist.


Product specificaties

Merk: Hunter
Categorie: Ventilator
Model: Halcyon 81030

Heb je hulp nodig?

Als je hulp nodig hebt met Hunter Halcyon 81030 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Hunter

Hunter

Hunter Bennett Handleiding

11 November 2024
Hunter

Hunter Gravity Handleiding

11 November 2024
Hunter

Hunter Minimus Handleiding

11 November 2024
Hunter

Hunter Neuron Handleiding

11 November 2024
Hunter

Hunter Rogers Handleiding

11 November 2024
Hunter

Hunter Rhinebeck Handleiding

11 November 2024
Hunter

Hunter Hardwick Handleiding

11 November 2024
Hunter

Hunter Swanson Handleiding

11 November 2024

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator

Livoo

Livoo DOM510 Handleiding

20 December 2024
Orava

Orava SF-13 Handleiding

18 December 2024
EMOS

EMOS P56PR2 Handleiding

14 December 2024
Midea

Midea FTS30-13AR Handleiding

14 December 2024
Midea

Midea FTS35-9AR Handleiding

14 December 2024
Midea

Midea FTS30-9AR Handleiding

14 December 2024