1 Welcome
Table of Contents
1 • Welcome ..............................................................2
2 • Installation Preparation ...............................3
3 • Receiver Installation ......................................4
4 • Transmitter Installation ...............................7
5 • Programming the Remote .........................8
6 • Operation ............................................................8
7 • Troubleshooting ........................................... 10
8 • Warranty ........................................................... 11
© 2010 Hunter Fan Company
Read and Save these Instructions
Caution: Risk of Electrical Shock!
All wiring must be performed in accordance with national
and local electrical codes. If you are unfamiliar with the
wiring codes, you should use a qualied electrician.
To avoid overheating and possible damage to other
equipment, do not install to control a receptacle, motor
operated appliance, or transformer-supplied appliance.
Use only to control one ceiling fan with or without a light
xture.
Ratings: 120 VAC, 60 Hz,1.0 Amp Fan Receiver Weight: 6 oz.
300 Watts incandescent light
44092-01 • 12/15/10 • Hunter Fan Company
3
2 Installation Preparation
Notes:
1. This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
2. This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from the one the
receiver is connected to.
• Consult the dealer or an experienced radio/TV technician for help.
3. For use only with electrically reversible ceiling fans rated at 1.0 amp or less,
and fan incandescent light kits rated at 300 watts or less.
4. Not for use with shaded-pole motors, Hunter 42” Low Prole fans, and
Hunter Baseball fans. Not recommended for use with the Hunter Original®.
For Hunter Original® series fans, use Hunter control model numbers 27187,
22691, or 27189.
5. Medium and Low fan speeds are determined by the control and thus may
vary from the factory settings due to normal motor variations.
6. For use with Hunter Hanging Systems (excludes Hunter Original) on at
ceilings or angled ceilings with a pitch up to 34°.
7. Not for use in applications where the fan does not have a wall switch.
Any changes or modications to this equipment not expressly
approved by Hunter Fan Company will void the user’s authority
to operate the equipment.
BEFORE YOU INSTALL THIS CONTROL:
USE THE PULL CHAIN SWITCH TO SET THE FAN SPEED
TO THE HIGH POSITION BEFORE INSTALLATION. DO
NOT USE THE PULL CHAIN TO CHANGE THE FAN SPEED
AFTER INSTALLATION, AS DAMAGE TO YOUR FAN OR
REMOTE MAY RESULT. THE SPEED OF THE FAN SHOULD
ONLY BE CHANGED BY THE HUNTER CONTROL!!


Product specificaties

Merk: Hunter
Categorie: Afstandsbediening
Model: 27209
Kleur van het product: Platina
Ingebouwd display: Nee
Gewicht: - g
LED-indicatoren: Ja
Aan/uitschakelaar: Ja
Plug and play: Ja
Maximumbereik: - m
Oplaadbaar: Nee
Input type: Drukknopen
juiste gebruik afstandsbediening: Speciaal
Batterijtechnologie: Alkaline
Type batterij: A23
Number of devices supported: 3

Heb je hulp nodig?

Als je hulp nodig hebt met Hunter 27209 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afstandsbediening Hunter

Handleiding Afstandsbediening

Nieuwste handleidingen voor Afstandsbediening

Vimar

Vimar 14172 Handleiding

1 December 2024
Vimar

Vimar 19172.B Handleiding

1 December 2024
Vimar

Vimar R14516 Handleiding

1 December 2024
Vimar

Vimar R19516.B Handleiding

1 December 2024
Vimar

Vimar R19516 Handleiding

1 December 2024
Vimar

Vimar R20516.N Handleiding

1 December 2024
Vimar

Vimar R16956 Handleiding

1 December 2024
Vimar

Vimar R20516.B Handleiding

1 December 2024
Vimar

Vimar R20516 Handleiding

1 December 2024