HP ProLiant DL80 G9 Handleiding

HP Server ProLiant DL80 G9

Lees hieronder de đź“– handleiding in het Nederlandse voor HP ProLiant DL80 G9 (123 pagina's) in de categorie Server. Deze handleiding was nuttig voor 65 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/123
HPE ProLiant DL80 Gen9 Server
Maintenance and Service Guide
Abstract
This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware
components and software. This guide is for an experienced
service technician. Hewlett Packard Enterprise assumes that you are qualified
in the servicing of computer equipment, trained in recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 785385- 003
April 2016
Edition: 4
© Copyright 2014, 2016 Hewlett Packard Enterprise Development LP
The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services
are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting
an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
Intel® and Xeon® are trademarks of Intel Corporation in the U.S. and other countries.
Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.
Microsoft® and Windows® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
microSD is a trademark or a registered trademark of SD-3C in the United States, other countries or both.
Contents 3
Contents
Customer self repair.................................................................................................................................. 6
Parts only warranty service ...................................................................................................................................... 6
Illustrated parts catalog ........................................................................................................................... 16
Mechanical components ......................................................................................................................................... 16
System components ............................................................................................................................................... 18
Removal and replacement procedures ................................................................................................... 24
Required tools ........................................................................................................................................................ 24
Safety considerations ............................................................................................................................................. 24
Preventing electrostatic discharge............................................................................................................... 24
Symbols on equipment ................................................................................................................................ 24
Server warnings and cautions ..................................................................................................................... 25
Rack warnings ............................................................................................................................................. 25
Preparation procedures .......................................................................................................................................... 26
Remove the security bezel (optional) .......................................................................................................... 27
Power down the server ................................................................................................................................ 27
Extend the server from the rack .................................................................................................................. 27
Access the product rear panel ..................................................................................................................... 30
Remove the server from the rack ................................................................................................................ 30
Remove the PCI riser cages........................................................................................................................ 31
Non- - hot plug drive carrier....................................................................................................................................... 32
Non- - hot plug drive.................................................................................................................................................. 33
Hot- plug drive blank ............................................................................................................................................... 34
Hot- plug drive ......................................................................................................................................................... 34
Access panel .......................................................................................................................................................... 35
Air baffle ................................................................................................................................................................. 36
4- - - bay LFF non hot plug drive backplane................................................................................................................ 37
4- - bay LFF hot plug drive backplane....................................................................................................................... 38
Smart Storage Battery ............................................................................................................................................ 39
Smart Storage Battery retainer ............................................................................................................................... 40
FBWC module ........................................................................................................................................................ 41
M.2 SSD enablement kit ......................................................................................................................................... 42
Fan blank ................................................................................................................................................................ 44
Hot- swap fan .......................................................................................................................................................... 45
DIMMs .................................................................................................................................................................... 46
Memory- processor compatibility information............................................................................................... 46
Removing the DIMM .................................................................................................................................... 46
Processor blank ...................................................................................................................................................... 47
Heatsink ................................................................................................................................................................ . 48
Processor ............................................................................................................................................................... 50
Expansion board .................................................................................................................................................... 54
Primary PCI riser cage blank .................................................................................................................................. 56
Onboard low profile PCI expansion slot cover- ....................................................................................................... 58
Primary PCI riser cage ........................................................................................................................................... 58
FlexibleLOM riser cage .......................................................................................................................................... 59
GPU riser board ..................................................................................................................................................... 59
Two- slot PCIe riser board....................................................................................................................................... 60
FlexibleLOM riser board ......................................................................................................................................... 61
System battery ....................................................................................................................................................... 62
Front I/O assembly ................................................................................................................................................. 63
Thumbscrew rack ears ........................................................................................................................................... 65
Quick ..................................................................................................................- release latch rack ear assembly 66
System board ......................................................................................................................................................... 69
HPE 550 W Power Supply ..................................................................................................................................... 76


Product specificaties

Merk: HP
Categorie: Server
Model: ProLiant DL80 G9
Gewicht: 27000 g
Breedte: 434.7 mm
Diepte: 634.3 mm
Hoogte: 87.6 mm
Frequentie van processor: 1.9 GHz
Processorfamilie: Intel® Xeon® E5 v3
Processormodel: E5-2609V3
Aantal processorkernen: 6
Grafische adapter: G200eH2
Inclusief besturingssysteem: Nee
Ethernet LAN: Ja
Processor lithografie: 22 nm
Aantal USB 2.0-poorten: 1
VGA (D-Sub)poort(en): 1
Aantal Ethernet LAN (RJ-45)-poorten: 2
Netvoeding: 550 W
Intern geheugen: 8 GB
Intern geheugentype: DDR4-SDRAM
Intel® Wireless Display (Intel® WiDi): Nee
Aantal poorten USB 3.2 Gen 1 (3.1 Gen 1) Type A: 2
Processor socket: LGA 2011-v3
Stepping: M1
Systeembus: 6.4 GT/s
Processor aantal threads: 6
PCI Express slots versie: 3.0
Processor operating modes: 64-bit
Processor cache: 15 MB
Bus type: QPI
PCI Express configuraties: x4, x8, x16
Thermal Design Power (TDP): 85 W
Codenaam processor: Haswell
Maximaal aantal PCI Express-lijnen: 40
Processor cache type: Smart Cache
ECC ondersteund door processor: Ja
Processorfabrikant: Intel
Maximum intern geheugen: 128 GB
Totale opslagcapaciteit: 0 GB
Soort optische drive: Nee
Ondersteunde instructie sets: AVX 2.0
Intel® My WiFi Technology (Intel® MWT): Nee
Intel® Hyper Threading Technology (Intel® HT Technology): Nee
Intel® Turbo Boost Technology: Nee
Intel® Quick Sync Video Technology: Nee
Intel® InTru™ 3D Technology: Nee
Intel® Clear Video HD Technology (Intel® CVT HD): Nee
Intel® Insider™: Nee
Intel® Flex Memory Access: Nee
Intel® AES New Instructions (Intel® AES-NI): Ja
Enhanced Intel SpeedStep Technology: Ja
Execute Disable Bit: Ja
Idle States: Ja
Thermal Monitoring Technologies: Ja
CPU configuratie (max): 2
Intel® Enhanced Halt State: Ja
Intel® Clear Video Technology for Mobile Internet Devices (Intel® CVT for MID): Nee
Intel® VT-x with Extended Page Tables (EPT): Ja
Ingebouwde opties beschikbaar: Ja
Intel® Secure Key: Ja
Intel® 64: Ja
Intel® OS Guard: Ja
Intel® Virtualization Technology for Directed I/O (VT-d): Ja
Intel® Clear Video-technologie: Nee
Intel® Virtualization Technology (VT-x): Ja
Verpakkingsgrootte processor: 52.5 x 45 mm
Conflictvrije processor: Nee
Intel® Identity Protection Technology (Intel® IPT): Nee
Versie Intel® Identity Protection Technology: 0.00
Versie Intel® Secure Key Technology: 1.00
ARK ID processor: 81897
Intel® Trusted Execution Technology: Ja
Intel® TSX-NI: Nee
Versie Intel® TSX-NI: 0.00
Intel® Anti-Theft Technology (Intel® AT): Nee
Type behuizing: Rack (2U)
Overtollige fans ondersteuning: Ja
Maximaal intern geheugen ondersteund door processor: 768 GB
Geheugentypen ondersteund door processor: DDR4-SDRAM
Klokgeheugen-snelheden ondersteund door processor: 1600,1866,2133 MHz
Kloksnelheid geheugen: 2133 MHz
Geheugenlayout: 1 x 8 GB
Geheugenslots: 8x DIMM
Ethernet interface type: Gigabit Ethernet
Aantal geĂŻnstalleerde processoren: 1
Geheugenbandbreedte ondersteund door de processor ( max): 51 GB/s
Chipset moederbord: Intel C610
Schaalbaarheid: 2S
FSB Parity: Nee
Front-side bus processor: - MHz
Tcase: 70.9 °C
Intel® Demand Based Switching: Ja
Physical Address Extension (PAE): Ja
Geheugenkanalen ondersteund door processor: Quad
Processorserie: Intel Xeon E5-2600 v3
Grafische adapter-familie: Matrox
Intel® Dual Display Capable Technology: Nee
Intel® FDI Technology: Nee
Intel® Rapid Storage Technology: Nee
Intel® Fast Memory Access: Nee
Intel® Smart Cache: Ja
HDD omvang: - "
Maximale opslagcapaciteit: - TB
Intel® Virtualization Technology (Intel® VT): VT-d, VT-x
aantal QPI links: 2
Aantal hoofdvoedingen: 1

Heb je hulp nodig?

Als je hulp nodig hebt met HP ProLiant DL80 G9 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Server HP

Handleiding Server

Nieuwste handleidingen voor Server