HP ProLiant BL465c G7 Handleiding

HP Server ProLiant BL465c G7

Lees hieronder de 📖 handleiding in het Nederlandse voor HP ProLiant BL465c G7 (98 pagina's) in de categorie Server. Deze handleiding was nuttig voor 52 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/98
HP ProLiant BL465c G7 Server Blade
User Guide
Part Number 594691-001
June 2010 (First Edition)
© Copyright 2010 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft, Windows, Windows Server, and Windows NT are U.S. registered trademarks of Microsoft Corporation.
Intel and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
AMD Athlon is a trademark of Advanced Micro Devices.
Intended audience
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Contents
Component identification ............................................................................................................... 6
Front panel components ................................................................................................................................ 6
Front panel LEDs .......................................................................................................................................... 6
SAS and SATA hard drive LEDs ..................................................................................................................... 7
SAS and SATA hard drive LED combinations .................................................................................................. 7
System board components 8 ............................................................................................................................
DIMM slot identification ...................................................................................................................... 9
Mezzanine connector definitions ....................................................................................................... 10
System maintenance switch ............................................................................................................... 10
System maintenance switch procedures .............................................................................................. 10
HP c-Class Blade SUV Cable ....................................................................................................................... 11
Operations................................................................................................................................. 13
Power up the server blade ........................................................................................................................... 13
Power down the server blade ...................................................................................................................... 13
Remove the server blade ............................................................................................................................. 14
Remove the access panel ............................................................................................................................ 15
Install the access panel ............................................................................................................................... 15
Setup ......................................................................................................................................... 16
Overview .................................................................................................................................................. 16
Installing server blade options .....................................................................................................................16
Installing interconnect modules ....................................................................................................................16
Interconnect bay numbering and device mapping ................................................................................ 16
Connecting to the network........................................................................................................................... 18
Installing a server blade .............................................................................................................................. 18
Completing the configuration....................................................................................................................... 20
Hardware options installation ....................................................................................................... 21
Introduction ............................................................................................................................................... 21
Memory option .......................................................................................................................................... 21
Single-, dual , and quad- -rank DIMMs ................................................................................................. 21
Memory subsystem architecture ......................................................................................................... 22
DIMM identification .......................................................................................................................... 22
Advanced ECC memory configuration ................................................................................................ 23
DIMM installation guidelines ............................................................................................................. 23
DIMM population order .................................................................................................................... 23
Installing DIMMs .............................................................................................................................. 24
Hot-plug SAS or SATA hard drive option ...................................................................................................... 25
Mezzanine card option .............................................................................................................................. 28
Processor option......................................................................................................................................... 29
HP Trusted Platform Module option ..............................................................................................................36
Installing the Trusted Platform Module board ....................................................................................... 36
Retaining the recovery key/password ................................................................................................. 37
Enabling the Trusted Platform Module ................................................................................................. 38
Cabling ..................................................................................................................................... 39
Hot-plug SAS/SATA hard drive cabling ........................................................................................................ 39


Product specificaties

Merk: HP
Categorie: Server
Model: ProLiant BL465c G7
Breedte: 55.6 mm
Diepte: 509.5 mm
Hoogte: 181.7 mm
Processorfamilie: AMD
Ethernet LAN: Ja
Aantal Ethernet LAN (RJ-45)-poorten: 2
Netvoeding: - W
Ethernet LAN, data-overdrachtsnelheden: 10,100,1000,10000 Mbit/s
Processor socket: Socket G34
ECC: Ja
Ethernet interface type: 10 Gigabit Ethernet,Fast Ethernet,Gigabit Ethernet
Chipset moederbord: AMD SR5690
Ondersteunde opslagstationinterfaces: Serial Attached SCSI (SAS),Serial ATA
LAN controller: HP NC551i
Soorten RAID: 0,1
Compatibele processors: AMD Opteron
Aantal ondersteunde processoren: 2
Maximum UDIMM geheugen: 512 GB
Aantal DIMM sloten: 16
Ondersteunende RDIMM klok snelheden: 1066,1333,1600 MHz
Aantal storage drives ondersteund: 2
Opslagschijf afmetingen ondersteund: 2.5 "
Ondersteunde geheugen types: DDR3-SDRAM
Hot-swap HDD bays: Ja
Moederbord southbridge: AMD SP5100
AMD Opteron series: 6100,6200