Honeywell CS92A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell CS92A (26 pagina's) in de categorie Temperatuurregeling. Deze handleiding was nuttig voor 70 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/26
User Guide
Y9120W Sundial RF2 Pack 4
How to use:
ST9120C Wireless Enabled Timer
CS92A Wireless Cylinder Thermostat
Honeywell Control Systems Ltd.
Arlington Business Park,
Bracknell
Berkshire
RG12 1EB
Technical Help Desk: 08457 678999
www.honeywelluk.com
50047645-002 A
Š 2011 Honeywell International Inc.
System Components
Energy Efciency and the Environment
Home energy use is responsible for more than Âź of the total UK carbon emissions
which contribute to climate change. Heating and hot water systems based on
boilers account for of this gure, so it is important to understand how your
controls can help to maximize energy efciency while maintaining your comfort.
Your Timer should be used in conjunction with appropriate temperature controls. In
order to save energy the following general points should be observed:
1. Ensure your system contains a room thermostat (where appropriate) and a hot
water thermostat, and that it is set to an appropriate temperature level, typically
20°C
2. Programme your heating (and hot water) to be off when you are not in the
house. If you are concerned about possible frost damage to any exposed pipe
work, it is advisable to fit a frost protection system – your installer can advise
you about this.
3. Think about how you use your domestic hot water – if you have a storage
system, it is not necessary to have this switched on all the time, even when you
are in the house.
4. Consider the heat up times required for your central heating. Every home
responds differently when the heating is switched on. Adjust the start time so
that you are not cold when you get up in the morning. A shorter heat up time is
required for other heating periods.
5. In the evening, when the house is up to temperature, it is often possible to
switch off the heating up to an hour before you go to bed, without any noticeable
reduction in comfort.
PLEASE RESPECT YOUR ENVIRONMENT!
Take care to dispose of this product and any
packaging or literature in an appropriate way
This document is to be left with the user
and forms part of a Home Information Pack
WHAT IS A PROGRAMMER?
...an Explanation for Householders (as recommended by the Energy Savings Trust)
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and
domestic hot water on and off at the same time, while others allow the domestic hot water and heating
to come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On
some programmers you must also set whether you want the heating and hot water to run continuously,
run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently
off. The time on the programmer must be correct. Some types have to be
adjusted in spring and autumn at the changes between Greenwich Mean
Time and British Summer Time. You may be able to temporarily adjust the
heating programme, for example, ‘Override’, ‘Advance’, or ‘Boost’. These
are explained in the manufacturer’s instructions. The heating will not work
if the room thermostat has switched the heating off. And, if you have a hot-
water cylinder, the water heating will not work if the cylinder thermostat
detects that the hot water has reached the correct temperature.
WHAT IS A CYLINDER THERMOSTAT?
...an explanation for Householders (as recommended by the Energy Savings Trust)
A cylinder thermostat switches on and off the heat supply from the boiler to the hot water cylinder.
It works by sensing the temperature of the water inside the cylinder, switching on the water heating
when the temperature falls below the thermostat setting, and switching it off once this set temperature
has been reached.
Turning a cylinder thermostat to a higher setting will not make the water heat up any faster. How quickly
the water heats up depends on the design of the heating system, for example, the size of boiler and
the heat exchanger inside the cylinder.
The water heating will not work if a time-switch or programmer has switched it off. And the cylinder
thermostat will not always switch the boiler off, because the boiler sometimes needs to heat the
radiators.
Cylinder thermostats are usually tted between one quarter and one third of the way up the cylinder.
The cylinder thermostat will have a temperature scale marked on it, and it should be set at between
60C and 65C, then left to do its job. This temperature is high enough to kill off harmful bacteria in the
water, but raising the temperature of the stored hot water any higher will result in wasted energy and
increase the risk of scalding.
Location
ST9120C
CS92A
(typically next to hot water cylinder, in bedroom)
This section is to be completed by the Installer
27
Keep this document in a Home Information Pack
This product and its associated documentation and packaging are protected by various intellectual
property rights belonging to Honeywell Inc. and its subsidiaries and existing under the laws of the UK
and other countries. These intellectual and property rights may include patent applications, registered
designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights.
Honeywell reserves the right to modify this document, product and functionality without notice. This
document replaces any previously issued instructions and is only applicable to the product(s) described.
This product has been designed for applications as described within this document. For use outside of
the scope as described herein, refer to Honeywell for guidance. Honeywell cannot be held responsible
for misapplication of the product(s) described within this document.
Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell
Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised
Representative Honeywell Inc.
CONFIGURATION & SERVICE DATACS92A CONTROLS LAYOUT
Boiler & System Service Log
The space below can be used to provide a record of boiler & system services and
the names and contact numbers of the Installer and Service Personnel.
This information is important for a Home Information Pack.
Service/Installation
Date
Installation/Service
Engineer
Telephone Number /
Contact Details
ST9120C CONTROLS LAYOUT
Sensor element Transceiver
Green light
(under button)
Button
Red light
(under button)
3
Contents
CONTROL OF YOUR SYSTEM
General Description of Controls in Your System ...............................................4
The way to use a Timer .....................................................................................4
Your Cylinder Thermostat .................................................................................5
GETTING STARTED WITH YOUR ST9120C
Step 1: Setting the Date & Time .......................................................................6
Step 2: Running a Built-in Programme .............................................................7
PROGRAMMING YOUR ST9120C
The Built-in Programmes / Your Personal Programme......................................8
Reviewing the Programme Times .....................................................................9
Modifying the Programme ................................................................................9
Disabling / Enabling Time Periods .................................................................11
OPERATING YOUR ST9120C
Choosing the Operating Mode .......................................................................12
Overriding the Operation Without Changing the Programmes.......................12
The Extra Hour Function .................................................................................13
The Holiday Function ......................................................................................13
Enquiry Mode .................................................................................................14
FINE TUNING YOUR ST9120C
Changing from AM/PM Time Display to the 24 Hour Clock............................15
Changing the Installer Parameters .................................................................15
BOILER SERVICE REMINDER
Countdown to Service / When Service is Due ................................................18
Shut-down .......................................................................................................19
OPERATING YOUR CS92A HOT WATER THERMOSTAT
Basic Operation ..............................................................................................19
Battery Replacement ......................................................................................19
Error Indications .............................................................................................20
FAQ AND TROUBLESHOOTING
Frequently Asked Questions ..........................................................................21
Troubleshooting Guide ...................................................................................23
CONFIGURATION & SERVICE DATA (to be completed by Installer) .................26


Product specificaties

Merk: Honeywell
Categorie: Temperatuurregeling
Model: CS92A

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell CS92A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Temperatuurregeling Honeywell

Handleiding Temperatuurregeling

Nieuwste handleidingen voor Temperatuurregeling