800-04965 8/09 Rev. A
ADEMCO CE3
Code Encryptor 3
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
The Code Encryptor 3 (CE3) provides wireless control for
arming/disarming a security system, opening/closing a garage door, and
activating a relay output (ex. turning on a light). The CE3 consists of a
Receiver and wiring harness, remote control keyfob, and a status LED
with optional mounting plate.
The most important factor for range and reliability is the mounting
location of the Receiver. Select a location that is as centrally located as
possible. Keep in mind that the user will want to control the operation of
the garage door from the driveway, and will also expect the use of the
remote for alarm on/off in the area of entry and exit.
Although you can wire the Receiver to the panel, it may reduce labor by
installing the CE3 Receiver at the point of entry and wire it to a nearby
keypad. In most cases this is the garage entry, which will provide an easy
installation for garage door open/close, status indicator, and alarm
controls through the keypad.
IMPORTANT: Do not mount the Receiver module inside the alarm panel
enclosure; it will reduce the reception of the remote keyfob.
CE3-006-V0
REMOTE
KEYFOB
LED STATUS INDICATOR
Red = Armed
Green = Disarmed
Yellow = Alarm
LED AND
MOUNTING
PLATE
WIRE
HARNESS
CODE ENCRYPTOR 3
RECEIVER
Installation Steps
1. Connect the CE3 Receiver to the control panel.
2. Program the CE3:
a. Associate the Receiver with the connected control using Automatic Recognition.
b. Program a user code for the Remote Keyfob.
3. Wire optional features, if used (Status LED, Garage Door Opener, Relay Outputs).
4. Test the System.
CONNECTING THE RECEIVER TO THE CONTROL PANEL
The Receiver can be wired either to the control’s terminals
or to a keypad’s terminals.
1. Unplug the Receiver from the wire harness.
2. Connect the Red, Black, Yellow and Green wires to the
keypad or control’s terminals as shown in the diagram.
NOTE: You can make these connections at the control or
at the keypad itself. If you place the Code Encryptor 3 in
the garage or any other location away from the control,
you may choose to wire the Code Encryptor 3 directly to
the keypad.
Summary of Basic Connections
Wire Color Connection
Red Keypad Red or Aux (+)
Black Keypad Black or Aux (-)
Green Keypad Green (control Data In)
Yellow Keypad Yellow (control Data Out)
† not used on GE Caddx NX panels
1
OFF
4
MAX
7
INST ANT
READY
2
AWAY
5
TES T
8
CODE
0
3
ST AY
6
BYPASS
#
ARMED
READY
9
CHIME
– 2
PROGRAMMING THE CODE ENCRYPTOR 3
Programming involves first associating the module with the control with which it is being used (auto recognition), and then
programming the remote control’s user code.
Automatic Recognition
1. Make sure the alarm panel is powered up and operating. The wire harness
should still be disconnected from the Receiver.
2. While watching the LED light on the CE3 Receiver, plug the wire harness
connector into the Receiver.
3. The Receiver’s LED will blink one time on power up. After about 2 seconds,
count the flashes that you see. The corresponding flashes indicate which
panel the Code Encryptor 3 has detected. Refer to the table below.
Control Panel Detection Table
No. of Flashes Alarm Panel detected by the CE 3
1 No Alarm connected (CE3 defaults to relay mode)
See Default Mode
2 Future use
3 **GE/NX4, NX6, NX8, NX8V2
4 Future use
5 Honeywell - Non-Addressable (Vista & 4110, XM, XMP)
6 Honeywell - VISTA Addressable (Vista P series controls 10, 15, 20, 21iP, 40, 50, 128, 250)
7 DSC- PowerSeries 816/832/5010/5020, PC1616/1832
8 DSC PC1550, 2525, 2550, 3000
9 **Napco P816/1632/3200
10 Future use
** For these panels, open top cover and slide switch away from LED
The Code Encryptor 3 on the following panels self-enroll themselves as a specific keypad address code.
Control Address
Honeywell addressable 3 (VISTA-40, 50, 128, 250)
Honeywell addressable (P controls) 17
IMPORTANT: DO NOT USE ANY OF THESE ADDRESS CODES IF YOU ARE USING ONE OF THE ABOVE CONTROLS.
Example: If you are using a Honeywell Vista P series control, no keypads can use address 17 because the CE 3 will automatically
enroll itself as address 17.
NOTE: If you are using the Honeywell Touchscreens, please remove them when Programming the Code Encryptor 3.
Programming the User Code
A user code for the Code Encryptor 3 must be programmed in the security system and in the CE3 Receiver. This provides the
system with a user code for arming and disarming of the control.
To program a user code into the Receiver, do the following:
1. Verify that the four-digit code you plan to teach the Code Encryptor 3 is a valid four-digit user code. Example: From the
keypad use that four-digit code to arm the panel. If the panel arms, the code is good. If it does not, program that user code into
the alarm panel. – The Code Encryptor 3 uses that four-digit code to arm and disarm the panel, thus that code must be valid.
NOTE: We recommend using a user code that the user cannot change. If the user code that is programmed into the Receiver
module is changed, the Code Encryptor 3 will not disarm the control panel.
2. Press and HOLD the program button on the Receiver. The LED will light. Continue to hold program button until the LED
turns OFF (in about 7 seconds). When the LED turns off, release the program button. The LED will begin to flash rapidly.
3. Using the keypad, slowly and firmly enter the four-digit user code (no other commands). After the fourth entry the LED will
stop flashing. This code has now been entered into the Code Encryptor’s non-volatile memory. The Code Encryptor will
remember this user code in the event of a power failure. To change to a new user code, repeat steps 2 and 3 above.
Adding/Deleting Remotes
To Add a New Remote
To add a remote to your Code Encryptor 3, do the following:
1. PRESS AND RELEASE the program button on the receiver.
The LED on the receiver will come ON.
2. Immediately PRESS button 1 on the new remote control
THREE TIMES. The LED on the receiver should go OFF
indicating the remote has been learned.
If the LED on the receiver stays ON, the remote has not
been learned. Remove and replace the harness, wait 15
seconds while auto recognition occurs and follow these
instructions again.
To Delete All Remotes
To delete a lost or stolen remote from the Code Encryptor 3,
you must purge the entire memory. This will delete all of the
current remotes. You will then have to add them back into
memory.
To purge, PRESS AND HOLD the program button. The LED
will come ON for four seconds, then go OFF, and finally it will
come ON again, indicating that all the remotes in memory
have been purged. Release the program button and follow the
To Add a New Remote instructions.
– 3
WIRING FOR OPTIONAL FEATURES AND APPLICATIONS
Summary of Harness Wire Functions
Purpose Wire Color Function
Red Keypad Red or Aux (+12VDC)
Black Keypad Black or Aux ()
Green Keypad Green (control Data In); Not Used on GE Caddx NX panels
Keypad
Connections
Yellow Keypad Yellow (control Data Out)
Purple LED Status Light Purple wire (Red light)
LED Status White/Purple LED Status Light white/purple (Green light)
Blue/Green Channel 4 N/C (5amp)
Brown/White Channel 4 N/O (5amp)
Relay Output
Button Brown Channel 4 Common (5amp)
White Channel 3 Common (Garage Door Pushbutton) Garage Door
Opener Red/White Channel 3 N/O relay (Garage Door Pushbutton)
Entry/Exit zone Gray Channel 1 (-) momentary output
Wiring the Status LED
The status LED is a low voltage type and must be wired to
the Code Encryptor 3. If you attempt to connect it any other
way, the LED will burn out and will NOT operate again.
Status LED Indications
LED Action Indication
Red LED Flashing Away mode
Red LED Solid Stay mode
Green LED Flashing Not Ready
Green LED Solid Ready
Yellow LED Flashing Rapidly Alarm occurred
Wiring to a Garage Door Opener (Channel 3 Application)
When button 3 is pressed, it activates a momentary contact closure for opening and closing a garage door. Occasionally, you may want
to use Channel 3 for control of other optional accessories (i.e., garage door motor, Malibu lighting, sprinklers, X-10 automation).
All garage doors have a wall mounted push button that
activates the door via a two-wire connection. Make your
connection at the push button switch or at the garage door
motor where these two wires terminate. Connect the red/white
and white wires from the CE3 to these two wires as shown. If
you choose to connect to the motor, trace the wires from the
push button to the motor and determine the proper connection
point. Most garage doors (except MOM Crusader models) use
terminals #1 and #2. For MOM Crusader models, use
terminals #2 and #3.
Channel 4 Applications
When Button 4 is pressed, it activates a 5A Form C relay (Common, N/O/, N/C). You can use this output trigger for a 2nd garage
door motor, Malibu lighting, sprinklers, or an X-10 power flash module to interface with lighting, perhaps to illuminate the
walkway as the users leave and return home.
Default Mode
When the Code Encryptor 3 is not connected to the data bus of a control panel, it acts as a 2-relay module.
Button 1 triggers Channel 3 - Relay 1 (momentary).
Button 2 triggers Channel 4 - Relay 2 (momentary).
Channel 1 Momentary (-) Output (Optional)
When you momentarily press button 1 on the Code Encryptor 3 remote, the Gray wire momentarily sends a 500ma (-) output.
You can use this output to trigger an exit/entry zone to ensure the panel goes into Away mode.
PANIC MODE
Press and hold buttons 1 and 2 on the remote control for police panic. This will cause the panel to go into a panic mode. Cancel
Panic at a keypad. THE REMOTE WILL NOT CANCEL A PANIC.
Activating panic mode
NOTE: This is the default setting of the Code Encryptor 3.
If you have previously programmed remote panic “OFF” and would like to turn it back “ON” follow the steps below. If this is a
new installation, Panic “ON” is the DEFAULT setting for the Code Encryptor 3.
1. Unplug the wire harness from the Code Encryptor 3.
2. Press and HOLD the program button.
3. While HOLDING the program button, plug the Code Encryptor 3 harness back in. The LED located on the front will turn ON.
4. Immediately release the program button. Auto recognition will start.
IF NECESSARY, PROGRAM THE ALARM PANEL FOR KEYPAD PANIC.


Product specificaties

Merk: Honeywell
Categorie: Afstandsbediening
Model: CEREMLXB
Kleur van het product: Zwart
Ingebouwd display: Nee
Interface: RF Draadloos
Aantal knoppen: 4
Maximumbereik: - m
Backlight toetsen: Nee
Frequentie: 433 MHz
Input type: Drukknopen
juiste gebruik afstandsbediening: Beveiligingssysteem

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell CEREMLXB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afstandsbediening Honeywell

Handleiding Afstandsbediening

Nieuwste handleidingen voor Afstandsbediening

Velleman

Velleman DVRRC4 Handleiding

3 December 2024
Vimar

Vimar 14172 Handleiding

1 December 2024
Vimar

Vimar 19172.B Handleiding

1 December 2024
Vimar

Vimar R14516 Handleiding

1 December 2024
Vimar

Vimar R19516.B Handleiding

1 December 2024
Vimar

Vimar R19516 Handleiding

1 December 2024
Vimar

Vimar R20516.N Handleiding

1 December 2024
Vimar

Vimar R16956 Handleiding

1 December 2024
Vimar

Vimar R20516.B Handleiding

1 December 2024