Hinkley Lighting Congress 3146AN Handleiding

Hinkley Lighting Verlichting Congress 3146AN

Lees hieronder de 📖 handleiding in het Nederlandse voor Hinkley Lighting Congress 3146AN (2 pagina's) in de categorie Verlichting. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
assembly instructions
Item No. 3140
1. Find a clear area in which you can work.
2.
3. Carefully review instructions prior to assembly.
from the ceiling, and then installing the glass.
star t here
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Drawing 2 - Fixture Mounting
Drawing 1 - Strap Detail
Drawing 3 - Glass Installation
J
B
G
A
01.01.13
3
2
1
H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon L ake, O H 440 12 800. 446. 5539 / 44 0.6 5 3 .550 0 h ink leyl ighti ng .com
D
C
E
1. Install screws (A) into mounting plate (B) - see Drawing 1.
Be sure the holes into which the screws are threaded mathc the spacing of the holes
(C) in the canopy (D) - see Drawing 1 and 2.
2. Attach mounting plate (B) to junction box (J), using screws (G) provided and then
slip supply wires through large center hole.
Make electrical connections from supply wire to the fixture lead wires. Refer to
instruction sheet and follow all instructions to make all necessary wiring (IS18)
connnections. Then refer back to this sheet to continue installation of this fixture.
1. Hang the fixture by slipping screws (A) through holes (C) of canopy
(D) - see Drawing 2.
2. (E) (B)Thread on ball knobs onto end of screws and tighten to secure fixture
to ceiling.
1. To install glass unthread knurled in bracket until glass can be slipped into(2) (1)
place - see .Drawing 3
2. Lamp fixture accordingly at this point.
3. (3) (1) (2) Slip glass into bracket and hand tighten knurled knob to secure glass.
330 00 Pin O ak Parkwa y Avon La k e, OH 4 4012 800 .44 6.55 39 / 440.653 .55 00 hinkl e yl i ghtin g.com
I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
wiring instructions
Indoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead with appropriately (B)
sized twist on connector - see .Drawings 1 or 2
2. Connect negative supply wire (typically white or the ribbed, marked (C)
side of the two-conductor cord) to negative fixture lead .(D)
3. Please refer to the below to complete all grounding instructions
electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked
side of the two-conductor cord) to positive fixture lead with appropriately (B)
sized twist on connector - see . Drawings 2 or 3
2. Connect negative supply wire (typically white or the ribbed, marked (C)
side of the two-conductor cord) to negative fixture lead .(D)
3. Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a
fixture mounting platform specially.
4. Please refer to the below to complete all grounding instructions
electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (typically copper or green plastic coated) to the fixture mounting strap (E) (1)
with the ground screw - see . (2) Drawing 1
Note: On straps for screw supported fixtures, first install the two mounting screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (typically copper or green plastic coated) under the (E)
head of the ground screw on fixture mounting strap and connect to the (2) (1)
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - see .Drawing 2
Post-Mount Fixtures
Connect fixture ground wire (typically copper or green plastic coated) to power (E)
supply ground with appropriately sized twist-on connector inside post. Cover open
end of connector with silicone sealant to form a watertight seal - see .Drawing 3
Drawing 1 - Flush Mount
Drawing 2 - Chain Hung
supply wire
fixture leads
twist-on
connectors
Drawing 3 - Post-Mount
twist-on
connectors
1
A CC
B D
supply wire
fixture leads
A C
B D
1
2
supply wire
fixture leads
A C
B D
twist-on
connectors
E
2
E
E
E
E
I.S. 18


Product specificaties

Merk: Hinkley Lighting
Categorie: Verlichting
Model: Congress 3146AN

Heb je hulp nodig?

Als je hulp nodig hebt met Hinkley Lighting Congress 3146AN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verlichting Hinkley Lighting

Handleiding Verlichting

Nieuwste handleidingen voor Verlichting