assembly instructions
Family: Bolla Item No. 4660
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
*** The construction of this fixture will be accomplished by first assembling the
main body of the fixture, making all necessary electrical connections, hanging
the fixture from the ceiling, and then installing the glass.
start here
4660
1. To assemble main body, take stem and thread one end into coupler - see (2) (A)
Drawing 3.
Drawing 3 - Fixture Assembly
1
2
3
4
5
7
10
9
A
Drawing 2 - Fixture Mounting
Drawing 1 - Strap Detail
B
(side view)
gull wing
bracket
B
8.10.10
1. Prepare gem strap for mounting by threading two screws provided into (A) (B)
back of gull wing bracket of gem strap - see .(A) Drawing 1
Be sure the holes into which the screws are threaded match the spacing of holes (D)
in the canopy - see .(E) Drawings 1 and 2
3. Mount gem strap to junction box , using the two 1” screws not provided.(A) (J) (C)
Make electrical connections from supply wire to fixture lead wires. Refer to instruction
sheet and follow all instructions to make all necessary wiring connections.(I.S. 18)
1. Hang the fixture by slipping the holes in the canopy over the screws in(D) (E) (B)
the mounting strap - see .(A) Drawing 2
2. Thread on ball knobs to secure fixture to the ceiling.(F)
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
3
4
5
6
68
031813
1. Prior to installing glass, fixture can be lamped accordingly.
2. (2) (A) To begin glass installation first thread threaded tubing into swivel mount
approximately 3/8”, and then tighten hex nut up against swivel mount to secure (H) (A)
threaded tube - see .(2) Drawing 3
3. (4) Next slide metal washer followed by plastic washer (3) onto threaded tube .(2)
4. While holding them in place, slip glass onto threaded tube .(5) (2)
5. While holding glass in place slip plastic washer followed by flat washer (5) (6) (7)
onto threaded tube , then thread hex nut onto threaded tube and tighten to (2) (8) (2)
secure glass.
6. Slip spider assembly onto end of threaded tube .(9) (2)
7. While holding in place, thread on finial to secure spider assembly . (10) (9)
revised 10.14.15
T24 JA8-2016
H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com
I.S. 18 wiri roun g n onsng g din i st ctiru
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
w t t siring ins ruc ion
Indoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead with appropriately (B)
sized twist on connector - see .Drawings 1 or 2
2. Connect negative supply wire (typically white or the ribbed, marked (C)
side of the two-conductor cord) to negative fixture lead .(D)
3. Please refer to the below to complete all grounding instructions
electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked
side of the two-conductor cord) to positive fixture lead with appropriately (B)
sized twist on connector - see . Drawings 2 or 3
2. Connect negative supply wire (typically white or the ribbed, marked (C)
side of the two-conductor cord) to negative fixture lead .(D)
3. Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a
fixture mounting platform specially.
4. Please refer to the below to complete all grounding instructions
electrical connections.
gr r sounding inst uction
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (typically copper or green plastic coated) to the fixture mounting strap (E) (1)
with the ground screw - see . (2) Drawing 1
Note: On straps for screw supported fixtures, first install the two mounting screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (typically copper or green plastic coated) under the (E)
head of the ground screw on fixture mounting strap and connect to the (2) (1)
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - see .Drawing 2
Post-Mount Fixtures
Connect fixture ground wire (typically copper or green plastic coated) to power (E)
supply ground with appropriately sized twist-on connector inside post. Cover open
end of connector with silicone sealant to form a watertight seal - see .Drawing 3
Drawing 1 - Flush Mount
Drawing 2 - Chain Hung
supply wire
fixture leads
twist-on
connectors
Drawing 3 - Post-Mount
twist-on
connectors
1
A CC
B D
supply wire
fixture leads
A C
B D
1
2
supply wire
fixture leads
A C
B D
twist-on
connectors
E
2
E
E
E
E
I.S. 18
H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com


Product specificaties

Merk: Hinkley Lighting
Categorie: Verlichting
Model: Bolla 4660BN

Heb je hulp nodig?

Als je hulp nodig hebt met Hinkley Lighting Bolla 4660BN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verlichting Hinkley Lighting

Handleiding Verlichting

Nieuwste handleidingen voor Verlichting